Reefe RHC2060 Instruction Manual Download Page 3

IMPORTANT NOTICE 

This pump is not suitable for 

outdoor use it must be protected 

from the weather by way of a 

weatherproof enclosure. Failure to 

do so voids all warranty. 

This  pump  must  not  be  run  dry,  it  must  be  installed  using 
barrel-union  connections,  by  a  licenced  person  who  is 
authorised to install this type of device. It MUST be installed 
so  that  if  it  were  to  leak,  fail  to  operate,  or  run  without 
stopping, that it would NOT cause damage or loss. It must be 
connected to an electrical circuit with a RCD (Safety Switch) 
having  a  rated  residual  operating  current  not  exceeding 
30mA.  Disconnect  pump  from  power  before  servicing  or 
repairing  the  pump.  Read  and  follow  the  instructions, 
warranty is void if instructions are not followed. 

Ascento Group Australia, LYTTON, QLD P: 1800 807 604 

Summary of Contents for RHC2060

Page 1: ...AD m Bare Pump With Union With Bush PORT TO PORT LENGTH Length 7372 RHC2060 3 0 45 100 48 6 130mm 185mm 150mm 2 0 35 70 35 4 5 PORTS PORTS PORTS 1 0 25 55 21 2 5 25mm 1 MBSP 20mm MBSP 32mm 1 MBSP Bare...

Page 2: ...oupled with a timer and the timer is set so that the pump only turns on when there is likely to be demand for hot water 8 The pump must be installed in the correct orientation the motor shaft must alw...

Page 3: ...to install this type of device It MUST be installed so that if it were to leak fail to operate or run without stopping that it would NOT cause damage or loss It must be connected to an electrical circ...

Page 4: ...TH MAXIMUM TEMPERATURE OF 110 C You MUST bleed the air out of the pump before turning on the power DANGER NOT to be used to pump flammable or hazardous liquids suitable for clean fresh water only Do n...

Page 5: ...ntation voids all warranty Pump must be protected from the weather Only qualified and competent tradespeople should attempt installation or electrical work Please read all instructions and warnings ca...

Page 6: ...t voids the warranty Maintenance and Repair Should the power cable need replacement it must be installed by a licenced electrician DANGER Disconnect from power before touching the pump Pump will be HO...

Page 7: ...Troubleshooting Guide...

Page 8: ...ibility to ensure that the product is fit for their purpose and of sufficient size performance for their application 8 IMPORTANT No electrical appliances last forever Therefore ALL installations of pu...

Reviews: