Reefe RHC2060 Instruction Manual Download Page 2

CIRCULATOR PUMP FUNCTION AND APPLICATION 

1. Maximum Mains Pressure 500kPa as per AS 3500.1
2. Maximum water temperature of 110°C

!! IMPORTANT !!

 Tempering valves should be installed in accordance

with  Australian  Standard  AS3500.4.2  Clause  1.6.  and  manufacturer’s

instructions.

3. This pump is used to circulate clean, fresh hot water around a ring main

so users have quick access to hot water when the pump is on.

4. Cold water applications are also suitable, minimum water temperature

of 5°C

5. It cannot be used  if  the pipework is  not in  a  ring  configuration 

  the

water must be able to 

CIRCULATE

.

6. Ensure the pump is sized correctly according to the demand.
7. To  reduce  power  cost  and  prolong  the  life  of  the  pump  it  is

recommended that the pump is coupled with a timer, and the timer is
set so that the pump only turns on when there is likely to be demand
for hot water.

8. The pump must be installed in the correct orientation, the motor shaft

must always be HORIZONTAL, refer to page 5

9. Always bleed the air out of the pump before turning it on, refer page 6
10. The  pump  must  be  protected  from  the  weather,  if  used  outdoors  it

must have a weatherproof shelter installed.

11. It  is  the  installers  responsibility  to  ensure  that  the  installation  is

compliant  with  relevant  PLUMBING  and  ELECTRICAL  regulations  and
LOCAL COUNCIL or SHIRE regulations or by-laws.

12. It is not recommended to mix different brands of pumps in the one ring-

main, it can lead to water hammer and destroy the pump impellers, this
situation is not covered by warranty.

WARNING!!

  This pump is not approved nor intended for use in swimming 

pools, spa pools or spa baths. 

TIP: use pipe lagging to reduce heat loss in the ring-main 

Summary of Contents for RHC2060

Page 1: ...AD m Bare Pump With Union With Bush PORT TO PORT LENGTH Length 7372 RHC2060 3 0 45 100 48 6 130mm 185mm 150mm 2 0 35 70 35 4 5 PORTS PORTS PORTS 1 0 25 55 21 2 5 25mm 1 MBSP 20mm MBSP 32mm 1 MBSP Bare...

Page 2: ...oupled with a timer and the timer is set so that the pump only turns on when there is likely to be demand for hot water 8 The pump must be installed in the correct orientation the motor shaft must alw...

Page 3: ...to install this type of device It MUST be installed so that if it were to leak fail to operate or run without stopping that it would NOT cause damage or loss It must be connected to an electrical circ...

Page 4: ...TH MAXIMUM TEMPERATURE OF 110 C You MUST bleed the air out of the pump before turning on the power DANGER NOT to be used to pump flammable or hazardous liquids suitable for clean fresh water only Do n...

Page 5: ...ntation voids all warranty Pump must be protected from the weather Only qualified and competent tradespeople should attempt installation or electrical work Please read all instructions and warnings ca...

Page 6: ...t voids the warranty Maintenance and Repair Should the power cable need replacement it must be installed by a licenced electrician DANGER Disconnect from power before touching the pump Pump will be HO...

Page 7: ...Troubleshooting Guide...

Page 8: ...ibility to ensure that the product is fit for their purpose and of sufficient size performance for their application 8 IMPORTANT No electrical appliances last forever Therefore ALL installations of pu...

Reviews: