Reefe RHB1590 Quick Start Manual Download Page 3

IMPORTANT NOTICE 

 

This pump is not suitable for 

outdoor use it must be protected 

from the weather by way of a 

weatherproof enclosure. Failure to 

do so voids all warranty. 

This  pump  must  not  be  run  dry,  it  must  be  installed  using 
barrel-union  connections,  by  a  licenced  person  who  is 
authorised to install this type of device. It MUST be installed 
so  that  if  it  were  to  leak,  fail  to  operate,  or  run  without 
stopping, that it would NOT cause damage or loss. It must be 
connected to an electrical circuit with an RCD (Safety Switch) 
having  a  rated  residual  operating  current  not  exceeding 
30mA.  Disconnect  pump  from  power  before  servicing  or 
repairing  the  pump.  Read  and  follow  the  instructions, 
warranty is void if instructions are not followed. 

 

IMPORTANT!! 

The pump bearing is lubricated by the pumped water.  This pump cannot run dry 
for periods exceeding 10 seconds.  Do not pump any flammable or corrosive liquids. 

 

DANGER!!   

USE FOR CLEAN FRESH WATER ONLY WITH MAXIMUM TEMPERATURE OF 60°C!! 

You MUST bleed the air out of the pump before turning on the power! 

Summary of Contents for RHB1590

Page 1: ...WER 230 240V MAXIMUM SIZE AMPS P1 W FLOW L min HEAD m LIQUID TEMP MAINS PRESSURE Bare Pump With Union PORT TO PORT LENGTH 18811 RHB1590 0 48 105 23 9 2 60 C 500kPa 160mm 215mm PORTS PORTS Max Mains Pr...

Page 2: ...e pipes the less pressure you will have at outlets 8 The pump must be installed in the correct orientation refer to page 5 9 Always bleed the air out of the pump before turning it on loosen the S S sc...

Page 3: ...would NOT cause damage or loss It must be connected to an electrical circuit with an RCD Safety Switch having a rated residual operating current not exceeding 30mA Disconnect pump from power before se...

Page 4: ...Dimensions Pump Parts Description and Accessories Installation Guide...

Page 5: ...INCORRECT Warning WARNING This pump WILL NOT TURN OFF if switched to MANUAL position II mode it will continue to run even when there is no water ENSURE that if MANUAL mode is used it is turned back t...

Page 6: ...nths to ensure no debris build up occurs this will affect reliability of pump use REMOVE PLUG FROM POWER POINT BEFORE TOUCHING PUMP ALLOW PUMP TO COOL BEFORE OPENING ENSURE INLET AND OUTLET BALL VALVE...

Page 7: ...AL position II mode it will continue to run even when there is no water ENSURE that if MANUAL mode is used it is turned back to AUTO position III or OFF as soon as it is no longer required Warranty is...

Page 8: ...ibility to ensure that the product is fit for their purpose and of sufficient size performance for their application 8 IMPORTANT No electrical appliances last forever Therefore ALL installations of pu...