SAFETY PRECAUTIONS
1. WARNING: this pump contains rare earth magnets on the activating arm, be very careful when disassembling these parts
— Do NOT allow the magnets to come into contact with any electronic devices, including watches, cell phones, tablets,
computers or any device containing electronic instruments or parts etc. DAMAGE TO ELECTRONIC DEVICES CAN
RESULT FROM CLOSE CONTACT WITH THESE MAGNETS.
2. Ensure that power voltage and frequency supply conforms to the power requirements specified on the product nameplate,
before use. It should be 230 to 240VAC, 50Hz.
3. This pump must be earthed, do not tamper with the earthing connections.
4. If the pump falls into the water, don’t try to remove it when power is on! First unplug it or turn off the main switch, and then
retrieve it. If it is safe to do so, open the pump and dry it out over several days. Then you must have a qualified &
licenced Electrician check your pump prior to using it again.
5. If the supply cord is damaged, it must be replaced by a qualified Electrician or a certified technician. Never carry the air
pump by the power supply cord. Disconnect the power supply to the pump when not in use, and before maintenance and
repairs.
6. Periodical maintenance of the appliance is necessary to maintain peak performance and safe functioning. The filter must
be inspected and cleaned if necessary, after the first 500 hours of operation, and then a suitable schedule of checking be
decided upon, to ensure the filter is cleaned at a suitable time, regularly. The diaphragms must be checked for wear & tear
at least every 3 months, and replaced as soon as wear or tear occurs, or by 6 to 12 months.
7. During operation, if the pumps stops inexplicably or if and when anything abnormal occurs, immediately unplug the power
cable from the outlet and contact your dealer or an Authorized Service Centre or qualified technician.
8. This pump is an Oil-less type requiring NO lubrication.
9. Consult your approved dealer before using at high altitudes.
10. NEVER have only ONE pump if your application is critical and relies upon the pump, you must have a backup pump at all
times, this is a condition of warranty.
TECHNICAL DATA
Model
RB80
RB90
RB100
Power
58W
70W
87W
Voltage
230 - 240
230 - 240
230 - 240
Frequency
50Hz
50Hz
50Hz
Standard Pressure
0.014MPa
0.015MPa
0.018MPa
Max Pressure
>0.044MPa
>0.040MPa
>0.045MPa
Rated Output
(at X.XXX MPa)
80L/min
(at 0.014MPa)
90L/min
(at 0.015MPa)
100L/min
(at 0.018MPa)
Approx. Noise
Level
41dB
46dB
48dB
Thermal Overload
120°C
120°C
120°C
Min/Max Ambient Temp.
-10/40°C
-10/40°C
-10/40°C
Weight
5.8kg
8.8kg
8.8kg
Size
202L x 177W x
186H mm
262L x 216W x
229H mm
262L x 216W x
229H mm
PERFORMANCE CURVE