SAFETY PRECAUTIONS 

1.  WARNING:  this pump contains rare earth magnets on the activating arm, be very careful when disassembling these parts 

— Do NOT allow the magnets to come into contact with any electronic devices, including watches, cell phones, tablets, 
computers  or  any  device  containing  electronic  instruments  or  parts  etc.  DAMAGE  TO  ELECTRONIC  DEVICES  CAN 
RESULT FROM CLOSE CONTACT WITH THESE MAGNETS.  

2.  Ensure that power voltage and frequency supply conforms to the power requirements specified on the product nameplate, 

before use.  It should be 230 to 240VAC, 50Hz. 

3.  This pump must be earthed, do not tamper with the earthing connections. 
4.  If the pump falls into the water, don’t try to remove it when power is on!  First unplug it or turn off the main switch, and then 

retrieve  it.    If  it  is  safe  to  do  so,  open  the  pump  and  dry  it  out  over  several  days.    Then  you  must  have  a  qualified  & 
licenced Electrician check your pump prior to using it again. 

5.  If the supply cord is damaged, it must be replaced by a qualified Electrician or a certified technician. Never carry the air 

pump by the power supply cord.  Disconnect the power supply to the pump when not in use, and before maintenance and 
repairs. 

6.  Periodical maintenance of the appliance is necessary to maintain peak performance and safe functioning.  The filter must 

be inspected and cleaned if necessary, after the first 500 hours of operation, and then a suitable schedule of checking be 
decided upon, to ensure the filter is cleaned at a suitable time, regularly. The diaphragms must be checked for wear & tear 
at least every 3 months, and replaced as soon as wear or tear occurs, or by 6 to 12 months.  

7.  During operation, if the pumps stops inexplicably or if and when anything abnormal occurs, immediately unplug the power 

cable from the outlet and contact your dealer or an Authorized Service Centre or qualified technician. 

8.  This pump is an Oil-less type requiring NO lubrication. 
9.  Consult your approved dealer before using at high altitudes. 
10.  NEVER have only ONE pump if your application is critical and relies upon the pump, you must have a backup pump at all 

times, this is a condition of warranty. 

 

 

TECHNICAL DATA 

Model 

RB80 

RB90 

RB100 

Power 

58W 

70W 

87W 

Voltage 

230 - 240 

230 - 240 

230 - 240 

Frequency 

50Hz 

50Hz 

50Hz 

Standard Pressure 

0.014MPa 

0.015MPa 

0.018MPa 

Max Pressure 

>0.044MPa 

>0.040MPa 

>0.045MPa 

Rated Output                

(at X.XXX MPa) 

80L/min           

(at 0.014MPa) 

90L/min            

(at 0.015MPa) 

100L/min          

(at 0.018MPa) 

Approx. Noise 

Level 

41dB 

46dB 

48dB 

Thermal Overload 

120°C 

120°C 

120°C 

Min/Max Ambient Temp. 

-10/40°C 

-10/40°C 

-10/40°C 

Weight 

5.8kg 

8.8kg 

8.8kg 

Size 

202L x 177W x 

186H mm 

262L x 216W x 

229H mm 

262L x 216W x 

229H mm 

 
 

PERFORMANCE CURVE 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 