INSTRUCTION MANUAL & WARRANTY EXTERNAL CONSTANT PRESSURE 

PUMPS

APPLICATION: CONSTANT PRESSURE PUMPS are fit for purpose when installed correctly according to these instructions;

For pumping of Clean Fresh Water at a temperature of +5°C to +40°C to: Garden Taps, Houses, Sheds, Cabins, Pressure Boosting, 

Clean Water Transfer, suitable Rain-to-Mains Systems (370Watt and greater motor size) and for no other use. They must not be used 

in hazardous locations or for liquids other than clean water, or for continuous operation.

DANGER: DO NOT INSTALL ANY PUMP if the premises does not have a Safety Switch (RCD)

IMPORTANT: 

Ensure the pump is the right size for your application, before you install it. A pump that is under-sized is not  faulty, and is 

not covered by warranty. Ensure the right size piping is used, small pipes reduce performance and cause the pump to use more power! 

See below for further information, and refer to the information on the box and/or label on the pump for the performance data. If in 

doubt consult with your dealer or a pump technician to ensure your pump is sized to suit your needs.

PERFORMANCE DATA

Refer to the information on the box.

NOTES: Performance data quoted is generally from test data, and can vary, and does not take into account factors in the installation 

such as loss of pressure and flow due to pipework & pipe-fittings & valves. Product depicted on the box and referred to in this 

document, and other diagrammatic instructions, may differ from the product supplied, due to design changes or improvements.

***Be aware that the Amps and Wattage will vary according to the load on the motor, the figures stated are approximate.

INSTALLATION GUIDELINES

Please read and follow the instructions including the diagrammatic instructions. Warranty is voided if the instructions are not followed.

1a.

 

IMPORTANT MANDATORY REQUIREMENTS FOR ALL INSTALLATIONS:

 

Before installing or servicing disconnect from the power 

supply. All pumps must be installed using barrel-union connections to facilitate easy servicing or replacement. Ball-valves or gate- 

valves must be fitted on the suction, and the discharge, and the Town-water backup supply where fitted. A Y-Strainer or Pre-filter must 

be installed on the suction to prevent particles entering the pump. Remove all swarf from the tank after cutting openings etc – swarf in 

the pump voids warranty. All instructions are conditions of warranty; all warranty is void if instructions are not followed.

It is recommended to install a Check-Valve in the discharge pipework, however DO NOT install the check valve directly on the discharge 

of the Pressure Controller, as this may cause it to malfunction, install the Check-Valve further down the pipe, before the first point of 

discharge.

1b.

 

IRRIGATION USE - MANDATORY REQUIREMENTS FOR ALL INSTALLATIONS: 

For any installation of these pumps  that  is supplying 

irrigation, you must fit an 18L or larger pressure tank. Air pressure must be set at 70% of maximum pump pressure.  Tank is simply fitted 

to the discharge pipework with a “tee”, anywhere between the pump and the first point of discharge.

2. POSITION

 Do not position the pump where it could take in solids or sludge. This pump is not to be used as your sole water supply. 

For critical applications where loss of water supply could cause serious consequences, use a DUAL PUMP System so you have a second 

water supply or use a TOWN-WATER BACK-UP SYSTEM. This pump is not designed for Fire Fighting purposes.

3. PROTECT FROM THE WEATHER:

 The pump must be protected from the weather, by way of a plastic pump cover or skillion roof 

cover, or similar. However the installer must ensure that there is adequate ventilation so the pump does not overheat.

4. IMPORTANT re INSTALLATION:

 This pump MUST NOT be installed in any manner that if it were to leak that it would cause damage 

or loss to property or persons. It MUST be installed in a well-ventilated and drained area. All warranty is void if this condition is not 

heeded and no liability can be accepted in the case of damage or loss caused by failing to comply with this  condition. If the pump 

leaks, the water must be able to drain away from the pump and not cause damage.

DANGER!!!! 

If water pools around the pump (from any source of water) it will cause a dangerous electrical hazard.

5. BASE must be LEVEL

 Fix the pump in place through the footplate using suitable fasteners, on a stable, level surface – the base must 

NOT be sloping even slightly – ensure it is level.

6. IMPORTANT NOTE re PUMP NOISE: 

Avoid installing pumps near bedrooms or neighbours bedrooms. Particularly JET pumps, due 

to their self-priming design they typically make more noise than a MULTISTAGE Pump. This is a feature of the pump design, it is not a 

fault, and is not a cause for warranty claims, as it is not a product fault. If noise is likely to cause problems, we recommend that you use 

a MULTISTAGE Pump, and install the pump AWAY from bedrooms.

Summary of Contents for 20586

Page 1: ...www reefe com au EXPLODED VIEW INSTRUCTION MANUAL JET PRESSURE PUMP P U M P S A U S T R A L I A BETTER FASTER EASIER BETTER FASTER EASIER MODEL PRJ100E CODE 20586 ...

Page 2: ...IER COMPONENTS MATERIALS 18 14A 11 17 16 24A POSITION COMPONENT MATERIAL 11 Pump Shaft Stainless Steel AISI 420F 14A Motor Bracket Kit In die casting alumnium UNI 5076 16 Impeller Techno Polymer 17 Mechanical Seal Carbon Ceramics 18 Pump Body Stainless Steel AISI 304 24A Diffuser Nozzle Venturi Techno Polymer ...

Page 3: ...ONENT POSITION COMPONENT 1 Fan Cover 11 Rotor Shaft 2 Fan 14 Motor bracket 3 Board 15 O Ring Kit 4 Capacitor 16 Left Impeller 5 Tie Rod 17 Complete Mechanical Seal 6 Driving Cap 18 Pump Body 7 Split Ring 19 Bracket Screw 8 Rear Bearing 25 Diffuser Kit 8A Front Bearing 55 Mechanical Seal Plate 9 Casing with wound stator 89 Pump Feet 10 Board Cover ...

Page 4: ...MP IS INSTALLED WITHOUT BARREL UNION S A Y STRAINER A BALL VALVE W R O N G DIAGRAM 3 DIAGRAM 4 TIP CLEAN THE Y STRAINER MONTHLY TO ENSURE PEAK PERFORMANCE SIMPLY UNDO THE BUNG AND LET IT FLUSH OUT MAKE SURE YOU RE FIT THE MESH FILTER TIP IF PUMP STARTS FREQUENTLY CHECK TOILET CISTERNS THEY ARE PROBABLY LEAKING PRESSURE TANKS CAN SAVE YOU MONEY AS THE PUMP DOES NOT HAVE TO START SO OFTEN TIP IMPORT...

Page 5: ... INSTALLATIONS WHERE THE PUMP IS ABOVE THE OUTLET OF THE TANK ALWAYS USE A FOOT VALVE IN THE TANK W R O N G DIAGRAM 7 DIAGRAM 8 W R O N G INCORRECT PUMP IS NOT INSTALLED ON A LEVEL SURFACE ALWAYS ENSURE THE PUMP IS INSTALLED LEVEL INCORRECT THE PUMP IS CONNECTED INCORRECTLY ALWAYS ENSURE WATER INLET AND OUTLET ARE CORRECT W R O N G W R O N G DIAGRAM 5 DIAGRAM 6 RAIN MAINS SYSTEMS MUST NOT BE USED ...

Page 6: ... YOUR TANK IT MAY BE EMPTY IMPORTANT FOR VERY LONG SUCTION INTAKE PIPEWORK IT IS CRITICAL THAT THE CORRECT PIPE SIZE IS USED ESPECIALLY IN SUCTION LIFT APPLICATIONS CHECK WITH A QUALIFIED PUMP TECHNICIAN FOR THIS TYPE OF INSTALLATION INCORRECT PIPES TOO SMALL FOR PUMP INLET USE 25mm PIPE INTERNAL DIAMETER WE RECOMMEND 30mm FOR BEST PERFORMANCE FOR PUMPS WITH 32MM INTAKE OR LARGER USE SUCTION PIPE ...

Page 7: ...correct installation IMPORTANT DO NOT EXPOSE THE PUMP DIRECTLY TO THE ELEMENTS WE RECOMMEND THE PUMP IS PROTECTED WITH A PUMP COVER IMPORTANT CONSIDER NEIGHBOURS WHEN INSTALLING THE PUMP ALL PUMPS MAKE SOME NOISE IMPORTANT ENSURE THE PUMP IS SIZED CORRECTLY FOR THE JOB TOO SMALL LOW PERFORMANCE AND MAY USE EXCESS POWER AND OR OVERHEAT THE MOTOR AND OR CAUSE PREMATURE FAILURE THIS IS NOT A WARRANTY...

Page 8: ...c swarf in the pump voids warranty All instructions are conditions of warranty all warranty is void if instructions are not followed It is recommended to install a Check Valve in the discharge pipework however DO NOT install the check valve directly on the discharge of the Pressure Controller as this may cause it to malfunction install the Check Valve further down the pipe before the first point o...

Page 9: ...mA in the circuit breaker 3 Phase 415 Volt Pumps must be installed by a licenced Electrician according to applicable Regulations Australian Standards Disconnect the pump from power supply when people are in the water or when servicing or repairing the pump All warranty is void if this instruction is not followed Plugging into existing outlets may cause low voltage supply to the motor which may tri...

Page 10: ...ANT NOTES a Do not switch the pump on and off frequently as this will cause damage to the electronics and void warranty b Do not attempt to adjust the flow via the intake pipework c If there is insufficient water the motor will stop See 15 f and also 19 d If the pump is idle for a long period of time or in very low temperature the water should be drained to avoid damage to the pump and or stagnati...

Page 11: ... flush clean and re assemble if it is the pump disconnect from the power supply and if you are competent to do so disassemble the pump and clean If not have a pump technician do it for you 4 Pump is air locked Start and stop several times by turning it on and off with 20 seconds between If this does not work see below regarding re priming the pump 5 Vertical pumping distance is too high Reduce dis...

Page 12: ...___________________________________________________________ Tick the boxes as the item is completed correct put n a if not applicable The Pump is being used for an appropriate purpose for which it is intended according to the instructions The Power Circuit the Pump is connected to is RCD Safety Switch Protected A Y Strainer or Pre filter is installed in the suction pipe to prevent particles enteri...