Reefe 20586 Exploded View & Instruction Manual Download Page 1

www.

reefe

.com.au

EXPLODED VIEW & 

INSTRUCTION MANUAL

JET

PRESSURE PUMP

 

P U M P S   A U S T R A L I A

BETTER • FASTER • EASIER

BETTER • FASTER • EASIER

MODEL: 

PRJ100E

CODE:

 20586

Summary of Contents for 20586

Page 1: ...www reefe com au EXPLODED VIEW INSTRUCTION MANUAL JET PRESSURE PUMP P U M P S A U S T R A L I A BETTER FASTER EASIER BETTER FASTER EASIER MODEL PRJ100E CODE 20586 ...

Page 2: ...IER COMPONENTS MATERIALS 18 14A 11 17 16 24A POSITION COMPONENT MATERIAL 11 Pump Shaft Stainless Steel AISI 420F 14A Motor Bracket Kit In die casting alumnium UNI 5076 16 Impeller Techno Polymer 17 Mechanical Seal Carbon Ceramics 18 Pump Body Stainless Steel AISI 304 24A Diffuser Nozzle Venturi Techno Polymer ...

Page 3: ...ONENT POSITION COMPONENT 1 Fan Cover 11 Rotor Shaft 2 Fan 14 Motor bracket 3 Board 15 O Ring Kit 4 Capacitor 16 Left Impeller 5 Tie Rod 17 Complete Mechanical Seal 6 Driving Cap 18 Pump Body 7 Split Ring 19 Bracket Screw 8 Rear Bearing 25 Diffuser Kit 8A Front Bearing 55 Mechanical Seal Plate 9 Casing with wound stator 89 Pump Feet 10 Board Cover ...

Page 4: ...MP IS INSTALLED WITHOUT BARREL UNION S A Y STRAINER A BALL VALVE W R O N G DIAGRAM 3 DIAGRAM 4 TIP CLEAN THE Y STRAINER MONTHLY TO ENSURE PEAK PERFORMANCE SIMPLY UNDO THE BUNG AND LET IT FLUSH OUT MAKE SURE YOU RE FIT THE MESH FILTER TIP IF PUMP STARTS FREQUENTLY CHECK TOILET CISTERNS THEY ARE PROBABLY LEAKING PRESSURE TANKS CAN SAVE YOU MONEY AS THE PUMP DOES NOT HAVE TO START SO OFTEN TIP IMPORT...

Page 5: ... INSTALLATIONS WHERE THE PUMP IS ABOVE THE OUTLET OF THE TANK ALWAYS USE A FOOT VALVE IN THE TANK W R O N G DIAGRAM 7 DIAGRAM 8 W R O N G INCORRECT PUMP IS NOT INSTALLED ON A LEVEL SURFACE ALWAYS ENSURE THE PUMP IS INSTALLED LEVEL INCORRECT THE PUMP IS CONNECTED INCORRECTLY ALWAYS ENSURE WATER INLET AND OUTLET ARE CORRECT W R O N G W R O N G DIAGRAM 5 DIAGRAM 6 RAIN MAINS SYSTEMS MUST NOT BE USED ...

Page 6: ... YOUR TANK IT MAY BE EMPTY IMPORTANT FOR VERY LONG SUCTION INTAKE PIPEWORK IT IS CRITICAL THAT THE CORRECT PIPE SIZE IS USED ESPECIALLY IN SUCTION LIFT APPLICATIONS CHECK WITH A QUALIFIED PUMP TECHNICIAN FOR THIS TYPE OF INSTALLATION INCORRECT PIPES TOO SMALL FOR PUMP INLET USE 25mm PIPE INTERNAL DIAMETER WE RECOMMEND 30mm FOR BEST PERFORMANCE FOR PUMPS WITH 32MM INTAKE OR LARGER USE SUCTION PIPE ...

Page 7: ...correct installation IMPORTANT DO NOT EXPOSE THE PUMP DIRECTLY TO THE ELEMENTS WE RECOMMEND THE PUMP IS PROTECTED WITH A PUMP COVER IMPORTANT CONSIDER NEIGHBOURS WHEN INSTALLING THE PUMP ALL PUMPS MAKE SOME NOISE IMPORTANT ENSURE THE PUMP IS SIZED CORRECTLY FOR THE JOB TOO SMALL LOW PERFORMANCE AND MAY USE EXCESS POWER AND OR OVERHEAT THE MOTOR AND OR CAUSE PREMATURE FAILURE THIS IS NOT A WARRANTY...

Page 8: ...c swarf in the pump voids warranty All instructions are conditions of warranty all warranty is void if instructions are not followed It is recommended to install a Check Valve in the discharge pipework however DO NOT install the check valve directly on the discharge of the Pressure Controller as this may cause it to malfunction install the Check Valve further down the pipe before the first point o...

Page 9: ...mA in the circuit breaker 3 Phase 415 Volt Pumps must be installed by a licenced Electrician according to applicable Regulations Australian Standards Disconnect the pump from power supply when people are in the water or when servicing or repairing the pump All warranty is void if this instruction is not followed Plugging into existing outlets may cause low voltage supply to the motor which may tri...

Page 10: ...ANT NOTES a Do not switch the pump on and off frequently as this will cause damage to the electronics and void warranty b Do not attempt to adjust the flow via the intake pipework c If there is insufficient water the motor will stop See 15 f and also 19 d If the pump is idle for a long period of time or in very low temperature the water should be drained to avoid damage to the pump and or stagnati...

Page 11: ... flush clean and re assemble if it is the pump disconnect from the power supply and if you are competent to do so disassemble the pump and clean If not have a pump technician do it for you 4 Pump is air locked Start and stop several times by turning it on and off with 20 seconds between If this does not work see below regarding re priming the pump 5 Vertical pumping distance is too high Reduce dis...

Page 12: ...___________________________________________________________ Tick the boxes as the item is completed correct put n a if not applicable The Pump is being used for an appropriate purpose for which it is intended according to the instructions The Power Circuit the Pump is connected to is RCD Safety Switch Protected A Y Strainer or Pre filter is installed in the suction pipe to prevent particles enteri...