Operating Instructions

Function selection 

1). Turn.on.the.meter.by.pressing.the.Power.Button..To.turn.the.meter.

off,.hold.the.Power.Button.for.over.2.seconds.

2). The.meter.has.2.measuring.functions.to.choose.from:.Air.velocity/

Temp.or.Type.K/J.Thermometer.

When.the.meter.is.on,.press.and.hold.the.Function.Button..The.display.will.
flash.“Air”,.for.Air.velocity/Temperature.measurement,.and.“tP”.for.Type.
K/J.Thermometer.measurement..Release.the.Function.Button.to.choose.
the.displayed.function.

Air velocity/Temperature measurement

1). When.the.meter.is.off,.plug.the.Air.Velocity.Probe.Plug.into.the.

Probe.Input.Socket,.then.power.on.the.meter.by.pressing.the.
Power.Button.

2). Select.the.“Air”.function.(see.Function.Select).
3). Hold.the.Probe.Handle.and.face.the.Probe.Head.against.the.mea-

suring.airflow.source..The.yellow.dot.on.the.sensor.head.indicates.
the.direction.that.needs.to.face.against.the.airflow..The.top.part.
of.the.Display.will.show.the.air.velocity,.and.the.lower.part.of.the.
Display.will.show.the.air.temperature.value..

Changing the Air velocity unit

To.change.the.Air.velocity.unit,.press.and.hold.the.Unit.Button..The.dis-
play.will.flash.the.units.m/S,.Km/h,.mph,.Knot,.&.FPM..Release.the.Unit.
Button.to.select.the.displayed.unit..The.select.unit.will.be.saved.as.the.
default.

www.netzerotools.com

www.netzerotools.com

Summary of Contents for SD-4207

Page 1: ...Black Model Instruction Manual Anemometer Thermometer Datalogger SD 4207 SD 4214 www netzerotools com www netzerotools com...

Page 2: ...velocity unit 7 Type K J Thermometer measurement 8 Data Hold 8 Data Record Max Min reading 8 Backlight ON OFF 9 Datalogger 9 Auto Datalogger 9 10 Manual Datalogger 10 Checking the Time 10 Check Sampl...

Page 3: ...sensor for fast response time Real time SD memory card datalogger with a built in clock and calendar Sampling time set from 1 second to 3600 seconds Meter can switch to a Manual Datalogging No extra...

Page 4: ...o 16 GB Sampling Time of Display Approx 1 second Data Output USB RS232 PC computer interface Temperature Range 0 50 C 0 122 F Resolution 0 1 C 0 1 F Accuracy 0 8 C 1 5 F Operating Temperature 0 50 C 0...

Page 5: ...126 0Km h 0 1Km h 2 0 8 Km h Mph 0 9 78 3mph 0 1mph 2 0 4 mph Knots 0 8 68 0 knots 0 1 Knots 2 0 4 Knots FPM 79 6890 FPM 1 FPM 2 40 FPM Type K J thermometer Sensor Type Resolution Range Accuracy Type...

Page 6: ...ment Description 1 Display 2 Power ESC Backlight Button 3 Hold Function Next Button 4 REC Enter Unit Button 5 SET Down Time Check Button 6 Logger Up Sampling Time Check Button 7 Probe input socket 8 T...

Page 7: ...ter measurement Release the Function Button to choose the displayed function Air velocity Temperature measurement 1 When the meter is off plug the Air Velocity Probe Plug into the Probe Input Socket t...

Page 8: ...ured value will hold on the screen and a HOLD symbol will appear Press the Hold Button once again will release the data hold function Data Record Max Min reading The data record function records the m...

Page 9: ...ed to adjust the clock See Advanced Settings section of this manual for instruc tions 4 Now you need to set the decimal format The numerical data struc ture downloaded to the SD card is defaulted used...

Page 10: ...time infor mation will be saved in memory The lower Display will show the Position record number which is saved as well 2 To Change the Position Number press the Down Button and the lower position nu...

Page 11: ...S files When that number has been reached the meter will then will generate a new folder with a subsequent number for example AMA02 Max number of AMA folders is 10 Data Transfer from SD card to Comput...

Page 12: ...et beeper sound ON OFF tYPE Select the Thermometer to Type K or Type J t CF Select the temperature unit to C or F SP t Set sampling time Hour Minute Second Sd F SD memory card Format While in the Adva...

Page 13: ...shows PoFF use the Up or Down But tons to select the value yES Enable Auto Power Off or no Disable Auto Power Off 2 After selecting yES or no press the Enter Button to save the setting as the default...

Page 14: ...ess the Esc Button Set sampling time 1 When the lower display shows SP t use the Up or Down Buttons to adjust the value to either 0 1 2 5 10 30 60 120 300 600 1800 or 3600 seconds 2 After the Sampling...

Page 15: ...m which can be utilized to the user s specific application An USB RS232 lead with the following connection will be required to link the instrument with the PC serial input Meter 3 5mm Jack Plug PC 9W...

Page 16: ...set Button with a Pin If the Reset Button does not fix the error please send in the unit to our Calibration Lab for repair E mail info reedinstruments com for more information Battery Replacement 1 Wh...

Page 17: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Page 18: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Page 19: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Page 20: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Reviews: