REED SD-4207 Instruction Manual Download Page 12

12

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Rich Black - 

20/20/20/100

Blue -  100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue -  100/80/30/5

Only if you REALLY need them:

Pantone 534 Blue -  100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Advanced Settings

During.normal.functions.(not.Datalogging),.press.and.hold.the.SET.Button.
for.2.seconds.to.enter.the.“Advanced.Setting”.mode..Press.the.Next.But-
ton.scroll.through.eight.main.functions,.shown.on.the.lower.display:

dAtE

.. Set clock.time.(Year/Month/Date,.Hour/Minute/Second)

dEC

Set SD.card.Decimal.character.

PoFF

. Auto.power.OFF.management.

bEEP

. Set beeper.sound.ON/OFF.

tYPE

. Select.the.Thermometer.to.Type.K.or.Type.J.

t-CF

. Select.the.temperature.unit.to.°C.or.°F

SP-t

. Set sampling.time.(Hour/Minute/Second).

Sd F

. SD.memory.card.Format

While.in.the.“Advanced.Setting”.function,.press.the.Esc.Button.to.exit.and.
to.return.to.normal.functioning..

Set Clock Time 

1). When.the.lower.display.shows.“dAtE”,.press.the.Enter.Button..

Use.the.Up.and.Down.Buttons.to.adjust.the.Year..After.the.desired.
value.is.set,.press.the.Enter.Button.to.adjust.the.Month,.Date,.Hour,.
Minute,.and.Second.values..

2). After.all.the.time.values.have.been.set.the.screen.will.jump.to.“SD.

card.Decimal.character”.setting.screen..To.exit.“Advanced.Set-
tings”,.press.the.Esc.Button.

Note

:. After.the.time.value.is.set,.the.internal.clock.will.run.even.when.

.

the.power.is.off,.if.the.battery.is.under.normal.conditions..

www.netzerotools.com

www.netzerotools.com

Summary of Contents for SD-4207

Page 1: ...Black Model Instruction Manual Anemometer Thermometer Datalogger SD 4207 SD 4214 www netzerotools com www netzerotools com...

Page 2: ...velocity unit 7 Type K J Thermometer measurement 8 Data Hold 8 Data Record Max Min reading 8 Backlight ON OFF 9 Datalogger 9 Auto Datalogger 9 10 Manual Datalogger 10 Checking the Time 10 Check Sampl...

Page 3: ...sensor for fast response time Real time SD memory card datalogger with a built in clock and calendar Sampling time set from 1 second to 3600 seconds Meter can switch to a Manual Datalogging No extra...

Page 4: ...o 16 GB Sampling Time of Display Approx 1 second Data Output USB RS232 PC computer interface Temperature Range 0 50 C 0 122 F Resolution 0 1 C 0 1 F Accuracy 0 8 C 1 5 F Operating Temperature 0 50 C 0...

Page 5: ...126 0Km h 0 1Km h 2 0 8 Km h Mph 0 9 78 3mph 0 1mph 2 0 4 mph Knots 0 8 68 0 knots 0 1 Knots 2 0 4 Knots FPM 79 6890 FPM 1 FPM 2 40 FPM Type K J thermometer Sensor Type Resolution Range Accuracy Type...

Page 6: ...ment Description 1 Display 2 Power ESC Backlight Button 3 Hold Function Next Button 4 REC Enter Unit Button 5 SET Down Time Check Button 6 Logger Up Sampling Time Check Button 7 Probe input socket 8 T...

Page 7: ...ter measurement Release the Function Button to choose the displayed function Air velocity Temperature measurement 1 When the meter is off plug the Air Velocity Probe Plug into the Probe Input Socket t...

Page 8: ...ured value will hold on the screen and a HOLD symbol will appear Press the Hold Button once again will release the data hold function Data Record Max Min reading The data record function records the m...

Page 9: ...ed to adjust the clock See Advanced Settings section of this manual for instruc tions 4 Now you need to set the decimal format The numerical data struc ture downloaded to the SD card is defaulted used...

Page 10: ...time infor mation will be saved in memory The lower Display will show the Position record number which is saved as well 2 To Change the Position Number press the Down Button and the lower position nu...

Page 11: ...S files When that number has been reached the meter will then will generate a new folder with a subsequent number for example AMA02 Max number of AMA folders is 10 Data Transfer from SD card to Comput...

Page 12: ...et beeper sound ON OFF tYPE Select the Thermometer to Type K or Type J t CF Select the temperature unit to C or F SP t Set sampling time Hour Minute Second Sd F SD memory card Format While in the Adva...

Page 13: ...shows PoFF use the Up or Down But tons to select the value yES Enable Auto Power Off or no Disable Auto Power Off 2 After selecting yES or no press the Enter Button to save the setting as the default...

Page 14: ...ess the Esc Button Set sampling time 1 When the lower display shows SP t use the Up or Down Buttons to adjust the value to either 0 1 2 5 10 30 60 120 300 600 1800 or 3600 seconds 2 After the Sampling...

Page 15: ...m which can be utilized to the user s specific application An USB RS232 lead with the following connection will be required to link the instrument with the PC serial input Meter 3 5mm Jack Plug PC 9W...

Page 16: ...set Button with a Pin If the Reset Button does not fix the error please send in the unit to our Calibration Lab for repair E mail info reedinstruments com for more information Battery Replacement 1 Wh...

Page 17: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Page 18: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Page 19: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Page 20: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Reviews: