Operating Instructions

1.  Turn the meter on by pressing the Power Button.
2.  Press the Time Weighting Button to select the desired Response 

Time. If the sound source consists of short bursts, set the response 

to FAST. To measure average sound level, select SLOW.

3.  Press the Frequency Weighting Button to select the Frequency. 

Select "A" Weighting for a general noise sound level, or "C" 

Weighting for measuring high level noise. "C" Weighting is a stan-

dard weighting of the audible frequencies commonly used for the 

measurement of Peak Sound Pressure Level. If the "C" Weighted 

level is much higher than the "A" Weighted level, then there will be a 

large amount of low-frequency noise.

4.  Press the UP and DOWN arrows to select the desired dB range. 

Choose a dB range in which the measured level is registering 

approximately in the middle of the bar graph. If the over range 

indicator appears during your measurement, the upper limit of the 

selected dB range has been exceeded. Adjust the selected dB range 

until the over range indicator disappears from the screen. Further-

more, if the under range indicator appears during your measurement, 

the lower limit of the selected dB range is too high to register your 

measurement. Adjust the selected dB range until the under range 

indicator disappears.

5.  Hold the instrument comfortably in one hand (away from your body) 

or position it on a tripod for long-term monitoring. Point the micro-

phone in the direction of the noise to take a measurement.

NOTE

: Direct contact with strong winds or blowing air on the microphone 

may cause measurement errors. These effects can be reduced by using 
the included windscreen.

MIN/MAX Hold

Press the MIN/MAX Hold button to display the Maximum and Minimum 

sound level values recorded during the measurement process.
1.  Press the MIN/MAX Hold Button once to display the maximum value.
2.  Press the button again to display the minimum value.
3.  Press and hold the button once more to resume normal operation.

continued...

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for R8060

Page 1: ...Sound Level Meter Instruction Manual R8060 www com information itm com 1 800 561 8187...

Page 2: ...C DC Signal Output Jack 8 Applications 9 Accessories and Replacement Parts 9 Product Care 9 Product Warranty 10 Product Disposal and Recycling 10 Product Support 10 Introduction Thank you for purchasi...

Page 3: ...ther than for the purpose of replacing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center Features...

Page 4: ...enser Digital Analog Bargraph Yes 30 segment Display 4 digit LCD Min Yes Max Yes Alarm Indicators Under and Over visual on screen Auto Shut off Yes after 30 mins off Tripod Mountable Yes Low Battery I...

Page 5: ...0 AC DC Output Terminal 11 Tripod Mounting Screw 12 Battery Cover Display Description Bar Graph Indicator Reading Indicator Battery Capacity Indicator C Weighting Indicator Auto Power Off Indicator Un...

Page 6: ...upper limit of the selected dB range has been exceeded Adjust the selected dB range until the over range indicator disappears from the screen Further more if the under range indicator appears during y...

Page 7: ...been exposed to extreme conditions or has not been used in a long period of time the meter should be calibrated by following steps 1 through 6 below 1 Remove windshield ball 2 While the meter is off p...

Page 8: ...external systems For example the AC output can be used with a frequency analyzer or oscilloscope to identify the frequency level during a measurement The DC output is used to identify the dB level du...

Page 9: ...your part listed here For a complete list of all accessories and replacement parts visit your product page on www reedinstruments com Product Care To keep your instrument in good working order we rec...

Page 10: ...at 1 877 849 2127 or by email at info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and...

Page 11: ...Test Measure with Confidence Check out our latest Products www com information itm com 1 800 561 8187...

Page 12: ...AIR VELOCITY TEMPERATURE HUMIDITY SOUND MOISTURE ELECTRICAL www com information itm com 1 800 561 8187...

Reviews: