Calibration
AC/DC Voltage
1.. Press.the.“ACA/DCA.200V”..
Function.Switch.
2.. Adjust.VR3.until.the.display..
shows.a.value.of.“0”.(See.Fig.1)
3.. Connect.a.standard.DC.voltage..
value.near.full.scale.(199.9.DCV)..
and.is.known.to.within.0.5%.accuracy
4.. Adjust.VR1.until.the.display..
shows.the.proper.DC.voltage
5.. Remove.the.standard.DC.voltage
6.. Connect.a.standard.AC.voltage.whose..
value.is.near.full.scale.(199.9.ACV).and..
is.known.to.within.0.5%.accuracy
7.. Adjust.VR4.until.the.display.shows..
the.proper.AC.voltage
AC/DC Current
1.. Press.the.“ACA/DCA.10A”.Function.Switch.
2.. Connect.a.standard.DC.or.AC.current.whose.value.is.near.full.
scale.(9.99.A).and.is.known.to.within.0.5%.accuracy.
3.. Adjust.VR5.until.the.display.shows.the.proper.AC.or.DC.current
4.. Remove.the.standard.AC.or.DC.current