background image

Pocket Size 

Moisture 

Detector

Instruction 

Manual

R6013

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for R6013

Page 1: ...Pocket Size Moisture Detector Instruction Manual R6013 www com information itm com 1 800 561 8187 ...

Page 2: ...tions 5 6 Getting Started 5 Changing the Electrodes Pins 5 Built in Measurement Verification 5 6 Built in Battery Check 6 Battery Replacement 6 Auto Power OFF 7 Applications 7 Accessories and Replacement Parts 7 Product Care 7 Product Warranty 7 8 Product Disposal and Recycling 8 Product Support 8 www com information itm com 1 800 561 8187 ...

Page 3: ...istributor or authorized Service Center Please note an additional fee for this service will apply Safety Never attempt to repair or modify your instrument Dismantling your product other than for the purpose of replacing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center Features Measures wood and b...

Page 4: ... Power Supply 3 CR2032 batteries Product Certifications CE Operating Temperature 32 to 104 F 0 to 40 C Storage Temperature 14 to 140 F 10 to 60 C Operating Humidity Range 0 to 85 Dimensions 5 1 x 1 6 x 1 130 x 40 x 25mm Weight 3 5 oz 100g Included Protective Cap Batteries Display Description The LCD displays two scales 1 The wood scale indicates wood moisture from 6 to 44 2 The building materials ...

Page 5: ...e your electrode pins follow steps 1 through 7 below 1 Using a Phillips head screwdriver remove the 5 screws on the back of the instrument 2 Remove the battery compartment to expose the batteries 3 Remove the batteries 4 Remove the housing lid 5 Using a Phillips head screwdriver remove the 4 screws located at the top of the electronic plate 6 Remove and replace the electrode pins 7 Reinstall the e...

Page 6: ...4 2 Building Materials 2 05 Display has to be full If during the battery check process the meter does not read within these parameters the batteries will need to be replaced Battery Replacement If the instrument does not automatically turn on when the protective cap is removed the LCD displays the or the Battery Check fails the batteries should be replaced as follows 1 Remove the Phillips head scr...

Page 7: ...ts R6013 P Replacement Pin Don t see your part listed here For a complete list of all accessories and replacement parts visit your product page on www reedinstruments com Product Care To keep your instrument in good working order we recommend the following Store your product in a clean dry place Change the battery as needed If your instrument isn t being used for a period of one month or longer pl...

Page 8: ... at 1 877 849 2127 or by email at info reedinstruments com to discuss the claim and determine the appro priate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulations when disposing or recycling your instrument Your product contains electronic components and must be disposed of separately from standard waste products Product Support If you have any que...

Page 9: ...Test Measure with Confidence Check out our latest Products www com information itm com 1 800 561 8187 ...

Reviews: