VADA - V-PC Auto Pressure Control

  Trouble  

 

Cause related to Pressure Control 

Causes not related to pressure control    

  Pump won’t start 

 

• The electronic card is broken  

• Voltage failure

   

 

 

 

 

 

• Pump jammed

   

 

 

 

 

 

• Electric cables inverted (line/motor)

   Pump won’t stop 

 

• The electronic card is broken  

• Presence of leaks which are higher than the minimum flow of 0.6  

   

 

• The reset button is blocked   

   l/min

   

 

• The flow detector is blocked in the upper  

 

 

 

 

 

 

   

 

   position  

 

 

 

 

 

 

 

 

 

   

 

• The pump does not provide sufficient    

 

 

 

 

 

 

   

 

   pressure 

 

  

 

 

 

 

 

 

   Intermittent pump working   

• The elctronic card is broken   

• Presence of leaks which are higher than the minimum flow of 0.6 

   

 

• The pump does not provide sufficient     l/min   

 

 

 

 

 

   

 

   pressure 

 

 

 

  Pump is jammed 

 

• The electronic card is broken  

• Water failure 

 

 

 

 

 

   

 

• The pump provides a pressure which    

 

 

 

 

 

 

   

 

   is lower than the restarting pressure   

 

 

 

 

 

  TROUBLESHOOTING - Auto Pressure Control