7 RX-2505PU System turn on and turn off
8 Troubleshooting & Maintenance
8.1 Troubleshooting
Once a fault occurs in the storage unit, the fault information can be displayed on the APP
/web
interface.
6.4 Communication
The system has an external USB interface, which contains 5V power supply and
RS
485
communication. Redx also has a
built-in
data collector. Users can choose to connect their own data
collector
(WIFI/GPRS function) according to their requirements, and use the computer or mobile
phone APP to monitor the machine
.
7.1 Turn on RX-2505PU system
You can perform the following steps to start the RX-2505PU:
1) Connect to the grid
2) Turn on the battery circuit breaker
3) Turn on the power button
4) When the LED display is normal, the system starts normally.
7.2 Turn off RX-2505PU system
You can perform the following steps to start the RX-2505PU:
1) Turn the unit off from
the power button
2)
Turn off the battery circuit breaker
3)
Turn off the AC circuit breaker
4)
When the LED display is off, the system is completely off
RX-2505PU
Route
r
Cable
PC
Figure
6
-
1
-
Network diagram
Rev 20220610
RX2505PU
Page 23 of 32