Alarm unit, Fiber optic cable & Sensor patch |
ENGLISH |
©
Guidance and manufacturer’s declaration – electromagnetic immunity
Redsense is intended for use in the electromagnetic environment specified below. The customer or the user of
Redsense should ensure that it is used in such an environment.
Redsense is intended for use in the electromagnetic environment specified below. The customer or the user of
Redsense should ensure that it is used in such an environment.
Immunity test
Immunity test
Electrostatic discharge
(ESD) IEC 61000-4-2
Electrical fast transient
/Burst IEC 61000-4-4
Surge IEC 61000-4-5
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines IEC 61000-4-11
Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
Conducted RF IEC
61000-4-6
Radiated RF IEC
61000-4-3
IEC 60601
test level
IEC 60601
test level
+/- 6 kV contact
+/-8kVair
+/- 2 kV for power
supply lines
+/- 1 kV for input
/output lines
+/- 1 kV differential
mode
+/- 2 kV common
mode
<5%UT (>95%dipinUT)
for 0,5 cycle 40%UT
(60%dipinUT) for
5 cycles 70%UT(30%
dipinUT) for 25 cycles
<5%UT(>95% dipinUT)
for 5 sec
3A/m
3 Vrms
1
50 kHz to 80 MHz
3 V/m
80MHz to 2,5GHz
Compliance
level
Compliance
level
+/- 6 kV contact
+/-8kVair
+/- 2 kV for power
supply lines n/a. for
input/ output
ines
+/- 1 kV differential
mode n/a. for
common mode
<5%UT (>95%dipinUT)
for 0,5 cycle 40%UT
(60%dipinUT) for
5 cycles 70%UT(30%
dipinUT) for 25 cycles
<5%UT(>95% dipinUT)
for 5 sec
3A/m
3 Vrms
3 V/m
Electromagnetic
environment
Electromagnetic environment –
guidance
Floors should be wood, concrete or ceramic tile.
If floors are covered with synthetic material, the
relative humidity should be at least 30 %.
Mains power quality should be that of a typical
commercial or hospital environment.
Mains power quality should be that of a typical
commercial or hospital environment.
Mains power quality should be that of a typical
commercial or hospital environment. If the user
of the [Equipment or System] requires continu-
ed operation during power mains interruptions,
it is re- commended that the [Equipment or
System] be powered from an uninterruptible
power supply or battery.
Power frequency magnetic fields should be
at levels characteristic of a typical location in a
typical commercial or hospital environment
Portable and mobile RF communications
equip- ment should be used no closer to any
part of Red- sense, including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency
of the transmitter.
Recommended separation distance
80 MHz to 800 MHz
800 MHz to 2,5 GHz
Where P is the maximum output power rating
of the transmitter in watts (W) according to
the trans- mitter manufacturer and d is the re-
commended separation distance in meters (m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site survey,
a
should be less than the compliance level in
each frequency range.
b
Interference may occur
in the vicinity of equipment marked with the
following symbol.