background image

 

Bulletin No. DA30D-A

Effective  2018-11-02

Drawing No. LP1078

 

-4-

CONFIGURING

 

A

 

DA30D

The DA30D is configured using Crimson

®

 3.1 software. Crimson is

available as a no charge download from Red Lion’s website. Crimson
updates for new features and drivers are posted on the website as they
become available. By configuring the DA30D using the latest  Crimson
version, you are assured that your unit has the most up to date feature
set. Crimson software can configure the DA30D through the RS232 PGM
port, USB port, Ethernet port or SD card.

The DA30D has three serial ports, a USB device port, one USB Host

port, and an Ethernet port as shown below.

The serial ports are available via RJ connectors. There are two RS232

ports. The port labeled RS232 (PGM) can be used as a Programming
Port or you can assign a protocol to it. The RS485 port can be used for
both RS485 or 422 communications. All of the serial ports are isolated.

The Ethernet port can be programmed to communicate via ten

protocols simultaneously. For more information on protocol support,
please refer to the Crimson 3.1 User Manual.

The USB device port is a standard device port with a Type B connector,

and is used as the programming port. The driver needed to use the USB
port will be installed with  Crimson.

The USB host port is a standard host port with a Type A connector  and

can be used to interface to USB enabled peripherals. This port supplies
5 V power per the USB standard.

The SD card can be used to program a DA30D by placing a database

image file on the SD card. The card is then inserted into the target DA30D
and powered. Refer to the Crimson 3.1 User Manual for more information
on the naming convention and location for this file.

USB,

 

DATA

 

TRANSFERS

 

FROM

 

THE

 

SD

 

CARD

In order to transfer data from the SD card via the USB port, a driver

must be installed on your computer. This driver is installed with Crimson
and is located in the folder C:\Program Files\Red Lion Controls\Crimson
3.1\Device\ after Crimson is installed. This may have already been
accomplished if your DAx0D was configured using the USB port.

Once the driver is installed, connect the DAx0D to your PC with a USB

cable, and refer to the “Mounting the SD Card” section in the Crimson 3.1
User Manual.

INSERTION/REMOVAL

 

OF

 

THE

 

SD

 

CARD

Insert the SD card into the slot provided with the card oriented as shown.

The card is inserted properly when the end of the card is flush with  the
DA30D case. To remove the SD card, push in slightly on the card.

CABLES

 

AND

 

DRIVERS

Red Lion has a wide range of cables and drivers for use with many

different communication types. A list of these drivers and cables along
with pin outs is available from Red Lion’s website. New cables and
drivers are added on a regular basis. If making your own cable, refer to
the “Port Pin Outs” that corresponds to your specific model for wiring
information.

ETHERNET

 

COMMUNICATIONS

Ethernet communications can be established at either 10 BASE-T or

100 BASE-TX. The unit’s RJ45 jack is wired as a NIC (Network Interface
Card). It auto-detects remote transmit and receive pairs and correctly
assigns the transmit and receive pairs. This feature enables the user to
use whichever type of cable (cross-over or straight) is available.

The Ethernet connector contains two LEDs. A yellow LED in the upper

right, and a green LED in the upper left. The LEDs represent the following
statuses:

On the rear of each unit is a unique 12-digit MAC address. Refer to the

Crimson manual and Red Lion’s website for additional information on
Ethernet communications.

RS232

 

PORTS

The DA30D has two

RS232 serial ports. Although
only one of these ports can
be used for programming,
both ports can be used for
communications with a PLC.
The serial ports can be used
for either master or slave
protocols with any DA30D
configuration. Each serial
port has a pair of LEDs to
indicate transmit and receive
activity. The pinouts are
shown to the right.

DA30D PORT PIN OUTS

COMM

(PGM)

TxB  (PIN 1)

TxA

RxB

RxA

TxEN

TxA  (PIN 8)

TxB

COMM

RTS  (PIN 6)

Tx

COMM
COMM

Tx

Rx

CTS  (PIN 1)

RTS  (PIN 6)

ETHERNET

(NIC)

TYPE B

USB

RS485/422

RS232

CTS  (PIN 1)

COMM

Rx

RS232

USB

TYPE A

SD STATUS (BLUE)

POWER (GREEN)

ALARM (RED)

FRONT PANEL LEDS

WARNING - DO NOT CONNECT OR DISCONNECT CABLES 
WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE 
NON-HAZARDOUS. USB DEVICE PORT IS FOR SYSTEM SET-UP 
AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT 
CONNECTION.

LED COLOR

DESCRIPTION

YELLOW solid

Link established.

YELLOW flashing

Data being transferred.

GREEN (OFF)

10 BASE-T Communications

GREEN (ON)

100 BASE-TX Communications

DAX0D RS232 TO A PC

DAx0D: RJ12

Name

PC: DB9

Name

4

COMM

1

DCD

5

Tx

2

Rx

2

Rx

3

Tx

N/C

4

DTR

3

COMM

5

GND

N/C

6

DSR

1

CTS

7

RTS

6

RTS

8

CTS

N/C

9

RI

COMMUNICATING

 

WITH

 

THE

 

DA30D

Summary of Contents for DA30D

Page 1: ...tual HMI The virtual HMI is programmed just like Red Lion s CR3000 series of HMIs Any standard web browser may be used to monitor or control the DA30D from a PC anywhere in the world The DAx0D is programmed with Red Lion s Crimson 3 1 software Crimson offers easy to use drag and drop communications configuration and is available as a no charge download from Red Lion s website DIMENSIONS In inches ...

Page 2: ... COMPLIANCES CE Approved EN 61326 1 Immunity to Industrial Locations Emission CISPR 11 Class A IEC EN 61010 1 RoHS Compliant UL Hazardous File E317425 Rugged IP40 enclosure 7 CONNECTIONS High compression cage clamp terminal block Wire Strip Length 0 3 7 5 mm Wire Gage Capacity 12 to 24 AWG 3 31 to 0 20 mm2 copper wire Torque 4 4 5 3 inch lbs 0 5 0 6 N m 8 CONSTRUCTION Polycarbonate enclosure with ...

Page 3: ...ifference between a successful or troublesome installation Listed are some EMI guidelines for a successful installation in an industrial environment 1 A unit should be mounted in a metal enclosure which is properly connected to protective earth 2 Use shielded cables for all Signal and Control inputs The shield connection should be made as short as possible The connection point for the shield depen...

Page 4: ...D CARD Insert the SD card into the slot provided with the card oriented as shown The card is inserted properly when the end of the card is flush with the DA30D case To remove the SD card push in slightly on the card CABLES AND DRIVERS Red Lion has a wide range of cables and drivers for use with many different communication types A list of these drivers and cables along with pin outs is available f...

Page 5: ...B 8 TxA 8 TxA CRIMSON 3 1 SOFTWARE Crimson 3 1 software is available as a no charge download from Red Lion s website The latest version of the software is always available from the website and updating your copy is free STATUS LEDS There are three status LEDs that show system status by default or they may be be user configured via System Functions using Crimson 3 1 Shown below is the default syste...

Page 6: ...ery is correct and as shown in the diagram Re install the battery holder with battery into the DAx0D unit Enter new date and time using Crimson 3 1 software CAUTION Lithium battery Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Please note that the old battery must be disposed of in a manner that complies with yo...

Page 7: ... 7 Effective 2018 11 02 Bulletin No DA30D A Drawing No LP1078 This page intentionally left blank ...

Page 8: ... BY LAW COURSE OF DEALING COURSE OF PERFORMANCE USAGE OF TRADE OR OTHERWISE Customer shall be responsible for determining that a Product is suitable for Customer s use and that such use complies with any applicable local state or federal law b The Company shall not be liable for a breach of the warranty set forth in paragraph a if i the defect is a result of Customer s failure to store install com...

Reviews: