background image

4

INCLUDED ACCESSORIES

TURBO / HIGH PRESSURE

1. Accessory Storage Case [ 91-0011 ]

2. Easy INTAKE

 [ 95-0082/B ]

Award-winning Easy INTAKE

 is an inflatable block off bladder  

with a pressurized vapor pass-through that allows technicians  
to test an entire intake or exhaust system quickly and easily

3. Power Intake

 Adaptor 1.9 in. (4.8 cm) Diameter [ 95-0086 ]

Inflatable block off bladder with a pressurized vapor pass-through

4. 

Daylight Spectrum LED Cordless Light [PN 96-0185]

Bright white beam finds even the tiniest wisps of vapor under the hood 
or chassis

 

5. OEM-Approved Smoke Producing Fluid  2x [ 96-0039 ] 8 fl. oz. (237 ml)

Vapor Producing Fluid will perform 100’s of typical tests per bottle  

Important

: Contains NO Dye / Contaminants

 

EVAP / LOW PRESSURE

6. EVAP Service Tool Kit [96-0003]

Schrader Valve Removal tool. Evap Service Port Adaptor.

7. Cap Plug Kit [ 96-0007 ]

Seals a variety of openings in order to pressurize system for testing.

8. EVAP Quick Connect Hose for Speed Smoke [ 96-0656 ]

 

1

1

2

3

4

5

6

1

7

8

1

Summary of Contents for 95-0135

Page 1: ...OPERATION MANUAL SPEED SMOKE P N 95 0135 DIAGNOSTIC LEAK DETECTOR ...

Page 2: ... Testing for High Pressure Leaks TURBO 8 9 Adaptor Installation 10 Safety 11 Troubleshoot Maintenance 11 Optional Accessories 12 Technical Support 1 877 55 SMOKE 1 714 451 1411 Email Support info RedlineDetection com You will receive a call or email response within six 6 hours Shop Online www RedlineDetection com ...

Page 3: ...AFORESAID WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES AND THERE ARE NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER MADE BY REDLINE EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR APPLICATION THE PURCHASER S SOLE REMEDY FOR ANY DEFECTIVE PRODUCT SHALL BE REPAIR REPLACEMENT OR REFUND AS STATED ABOVE AN...

Page 4: ...ectrical power 6 Flow Control Valve Variable Releases vapor pressure into the system Close flow control valve to lock out system for pressure decay testing 7 Test Pressure Gauge Indicates test pressure set by regulator 8 Vapor Test Switch Begins ten minute vapor cycle Red light indicates vapor cycle Push again to stop testing 9 Air Only Test Switch Begins ten minute air only cycle Blue light indic...

Page 5: ...ure into the system Close flow control valve to lock out system for pressure decay testing NOTE Fixed Pressure 11 14 in wc 0 47 PSI 0 032 BAR adjustable regulator only affects high pressure testing REAR BACK VIEW 16 Fluid Fill Port Remove fluid fill plug to fill machine with Redline approved vapor producing agent 17 12 Volt DC Power Cable 18 Compressed Air Inert Gas Inlet Replace coupler fitting i...

Page 6: ...apor pass through 4 Daylight Spectrum LED Cordless Light PN 96 0185 Bright white beam finds even the tiniest wisps of vapor under the hood or chassis 5 OEM Approved Smoke Producing Fluid 2x 96 0039 8 fl oz 237 ml Vapor Producing Fluid will perform 100 s of typical tests per bottle Important Contains NO Dye Contaminants EVAP LOW PRESSURE 6 EVAP Service Tool Kit 96 0003 Schrader Valve Removal tool E...

Page 7: ...o vehicle with the engine running 3 CONNECT TO AIR SUPPLY OPTIONAL a Connect compressed air supply or regulated inert gas supply to Air Inlet Replace quick coupler fitting if necessary 1 4 in NPT male 4 TO ADJUST FOR EVAP LOW PRESSURE TESTING Push Vapor or Air Only Test to begin 10 minute cycle Push again to stop a RED LIGHT indicates Vapor Test BLUE LIGHT indicates Air Only Test b Flow Meter indi...

Page 8: ...ed to step 2 to find leaks 2 Remove the fuel cap 3 Open Flow Control Valve to input vapor into the system through adaptor 4 Replace fuel cap when dense vapor is seen exiting the filler neck 5 Continue pumping vapor into the system 6 Using the provided Halogen Inspection Light inspect for leaks under the hood and tracing the route of the EVAP system on the underside of the vehicle 7 Repair the syst...

Page 9: ... other tailpipe to seal the system 2 Put Vapor Output Hose into Cone Adaptor to introduce vapor into the system A hot catalytic converter may consume some of the vapor All testing is performed with the engine off HowTo Diagnose Under Dashboard Leaks Many vehicles have a common vacuum line leading from the engine compartment through the fire wall under the dashboard This line supplies vacuum to cli...

Page 10: ...ake and exhaust system at one time Many engine systems can be tested from the air box to the tip of the exhaust completely in a single test To do so install Power Intake Adaptor see instructions into intake ducting after air cleaner box AND install Power Intake Adaptor see instructions into exhaust pipe Convert Power Intake Adaptor in exhaust system into a block off by installing block off coupler...

Page 11: ... leaks Retest after repairs are performed to confirm proper repair and seal Coolant System LeakTesting Cooling system leak testing can be performed two ways Use Speed Smoke to quickly and easily find cooling system leaks either with decay testing or using visible vapor First attach provided cooling system adaptor to pressurized coolant bottle or radiator at cap For decay testing simply pressurize ...

Page 12: ...tion pressure with Power Intake Adaptor or a test pressure that is greater than the capacity of the weakest component in the system under test NEVER use Power Intake Adaptor when its failure could cause injury or catastrophic damage Before use Refer to Power Intake Adaptor Installation and Inflation procedures back pressure limitations and tether restraint installation instructions Installing Powe...

Page 13: ...rnal component Contact Redline Detection Technical Support No Air Flow Open the flow control valve Check hoses are not kinked Poor Vapor Density or Volume Insufficient Vapor Producing Fluid Refill Flow Control Valve is partially closed Vapor Output Hose is kinked High Test Pressure Reading Vapor Output Hose is kinked TROUBLESHOOTING MAINTENANCE ...

Page 14: ... vapor producing fluid for 500 typical tests 5 XL Cone Adaptor PN 96 0055 For use to seal openings from 3 4 in 8 6 cm to 5 25 in 13 3 cm to introduce vapor into exhaust and induction systems 6 Cooling System Adaptor 96 0086 To test cooling system or coolant reservoir attach to radiator 7 SmokeMeister Wand 96 0088 Tube delivers vapor to find wind and water leaks in cabin or trunk 8 Wand Tip Adaptor...

Page 15: ......

Page 16: ...Manufactured By Redline Detection LLC Technical Support 1 714 451 1411 Shop Online www RedlineDetection com P N 01 0194 ...