B-13
Appendix B AN100U/UX Event Log Messages
Redline Communications Inc. Confidential and Proprietary
Startup Messages
Average Noise Floor on the
Uplink Channel = -x dBm
The sector controller reports the level
of noise measured at the RF input.
There is no required action, if the reported level
is below -100 dBm for 7 MHz and -103 dBm for
3.5 MHz.
See “Noise Floor Calculation” on page B-20 for
information on how the sector controller
calculates the average noise floor.
CRITICAL: Default FPGA
code loaded. Waiting for
upgrade...
The default firmware has been loaded
into the PHY and MAC FPGAs.
A system upgrade is required. Refer to the
RedMAX AN100U/UX Base Station User Guide.
CRITICAL: FPGA
Programming Failed
PHY and MAC FPGAs cannot be
programmed properly. Possible
firmware corruption.
Upgrade the sector controller to the latest
software version. If you are currently at the latest
software version, then contact
[email protected].
CRITICAL: PHY Initialization
Failed
PHY does not respond to initialization
commands.
Upgrade the sector controller to the latest
software version. If you are currently at the latest
software version, then contact
[email protected].
CRITICAL: PHY programming
failed.
The PHY is not able to execute Tx/Rx
commands with the current
configuration (channel bandwidth and
cyclic prefix).
Upgrade the sector controller to the latest
software version. If you are currently at the latest
software version, then contact
[email protected].
CRITICAL: RF programming
failed
The RF does not respond to
initialization commands.
Repeat the system upgrade operation. Refer to
the RedMAX AN100U/UX Base Station User
Guide.
Invalid Radio Type
The radio that is connected to the
AN100U/UX is not compatible with the
IDU.
Ensure that you are using the proper radio type.
If you are unsure whether your particular ODU is
compatible with your AN100U/UX, please
contact [email protected].
This message can also be displayed if the radio’s
inrush current at startup exceeds that available
from your power supply. In this case the power to
the IDU is interrupted resulting in the message.
See “Inrush Current at Startup” on page 5-7.
Invalid Radio Type
The IDU does not detect an ODU
connected to the IF port.
Ensure all cables are in good repair and are
connected properly. See “Replacing a Radio” on
page 4-1 for details on verifying the connections.
Long Reset
The AN100U/UX has been reset to
factory defaults by the user.
This is accomplished by pressing and holding the
Reset button on the front of the
AN100U/UXchassis for 10+ seconds.
Table B-1
AN100U/UX Event Log Messages (continued)
Message
Description
Comment