background image

• 

4

 •

Always run a test to establish whether the converter will operate a particular piece of 

equipment or device. In the event of a power overload, the converter is designed to 

automatically shut down. 

This safety feature prevents damaging the converter while testing devices and 

equipment within the wattage range of the converter.

When using the vehicle’s 12 volt accessory port, this converter is designed to supply 

60 to 70 watts when the vehicle is not running. With the vehicle’s engine running, it 

can supply up to 100 watts. To use the full output, you must connect the converter 

directly to your battery.

NOTE:

 

The 100 watt limit is to accommodate the fuse ratings for all vehicles. Some 

vehicles may allow the full output. If the fuse blows when you switch on the device 

you are trying to use, you have to either use a smaller device or you must connect the 

converter directly to the battery.

IMPORTANT: This converter uses a modified sine waveform (diagram A) which is not 

quite the same as power company electricity (diagram B). For the following devices, we 

strongly recommend that you use caution and check the device’s manual to make sure 

it is compatible with modified sine waveform.

1.  Switch mode power supplies 

2.  Linear power supplies 

3.  Class 2 transformers 

4.  Line filter capacitors 

5.  Shaded pole motors 

6.  Fan motors 

7.  Microwave ovens 

8.  Fluorescent and high intensity lamps (with a ballast) 

9.  Transformer less battery chargers 

Using the converter with any of these devices may cause the device to run warmer 

or overheat. 

Modified sine waveform 

produced by converter

Diagram A

Diagram B

Pure sine waveform 

typical of home AC outlet

Summary of Contents for RF7101

Page 1: ...READ BEFORE EACH USE This manual will explain how to use the converter safely and effectively Please read and follow these instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL US...

Page 2: ...ervice or repair is required Incorrect reassembly may result in a risk of fire or electric shock 1 11 Make sure the converter is not close to any potential source of flammable fumes gases or clothing...

Page 3: ...a short period of time of an hour or less Do not use the converter with a product that draws a higher wattage than the converter can provide as this may cause damage to the converter and product When...

Page 4: ...output If the fuse blows when you switch on the device you are trying to use you have to either use a smaller device or you must connect the converter directly to the battery IMPORTANT This converter...

Page 5: ...er NOTE You may hear a buzzing sound being emitted from the cooling fan 4 Make sure the device to be operated is turned OFF 5 Plug the device into the converter s AC outlet or USB port 6 Turn the devi...

Page 6: ...y shutdown occurs and the converter shuts off Recharge or replace the battery 2 When the power input from the vehicle s battery exceeds 15 volts high voltage protection occurs Reduce the voltage range...

Page 7: ...0 SPECIFICATIONS Maximum continuous output 140 Watts Surge capability 0 1 second 280 Watts No load current draw 0 25A Input voltage range 10 5V 15 5V DC Output voltage range 120V 5 AC Low voltage shut...

Page 8: ...d by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied or statutory warranti...

Page 9: ...sarme el inversor h galo revisar por una persona capacitada que efect e reparaciones cuando necesite servicio de mantenimiento o una reparaci n Volver a ensamblar el inversor en forma incorrecta puede...

Page 10: ...producto contiene una o m s sustancias qu micas conocidas en el Estado de California como causantes de c ncer y defectos de nacimiento u otros da os reproductivos 2 CARACTER STICAS 1 Recept culo de C...

Page 11: ...nistrar de 60 a 70 watts En Marcha puede llegar a abastecer hasta 100 watts Para usar la m xima potencia de salida usted debe conectar el convertidor directo a la bater a NOTA El l mite de 100 watts e...

Page 12: ...E OPERACI N CONEXI N DEL CONVERTIDOR IMPORTANTE Aseg rese de conectar su convertidor a una fuente de energ a de 12 V solamente 1 Quite el encendedor de cigarrillos de su toma de corriente 2 Empuje la...

Page 13: ...ay dos etapas involucradas en la conversi n de la energ a de 12 V de CD bater a a 120 V de CA voltaje dom stico ETAPA 1 El convertidor de corriente usa un transformador de CD a CD para aumentar la apo...

Page 14: ...nte por una polaridad inversa como un cortocircuito dentro del dispositivo o equipo siendo operados Si el fusible se quema 1 Desconecte el dispositivo o equipo inmediatamente 2 Encuentra la fuente del...

Page 15: ...asistencia services schumacherelectric com www batterychargers com o llame 1 800 621 5485 Lunes viernes 7 00am to 5 00pm CST Para REPARACI N O DEVOLUCI N comun quese con Servicios al Cliente al 1 800...

Page 16: ...citas de comerciabilidad o adecuaci n a un fin espec fico Asimismo el Fabricante no ser responsable ante reclamos por da os accidentales especiales ni directos en los que incurran los compradores usua...

Page 17: ...ualifi 1 10 Ne pas d monter le convertisseur prenez le un technicien qualifi quand une r paration est n cessaire Un remontage incorrect peut entra ner un risque d incendie ou de choc lectrique 1 11 S...

Page 18: ...fornie pour causer cancer des malformations cong nitales ou d autres troubles de la reproduction 2 CARACT RISTIQUES 1 Prise CA 2 Indicateur DEL 3 Connecteur positif 4 Connecteur n gatif 5 Ports USB 2...

Page 19: ...e fonctionnement du v hicule il peut fournir jusqu 100 watts Pour utiliser la pleine puissance vous devez connecter le convertisseur directement votre batterie NOTE La limite de 100 watts doit ajuster...

Page 20: ...SATION CONNEXION DU CONVERTISSEUR IMPORTANT S assurer de raccorder votre convertisseur une alimentation 12V uniquement 1 Retirer l allume cigare de sa prise 2 Enfoncer fermement la prise 12V dans la p...

Page 21: ...aut le d brancher pour viter de vider la batterie 6 COMMENT CONVERTISSEURS TRAVAIL Il ya deux tapes dans la conversion de 12 volts CC batterie en 120 volts AC tension des m nages ETAPE 1 Le convertiss...

Page 22: ...ait pas avoir besoin normalement d tre remplac Un fusible qui saute grill provient habituellement d une inversion de polarit ou d un court circuit dans l appareil ou l quipement Si le fusible saute 1...

Page 23: ...que au services schumacherelectric com www batterychargers com ou composez le 1 800 621 5485 Du lundi au Vendredi 07h00 17h00 CST Pour R PARATION OU AU RETOUR communiquer avec le Service la client le...

Page 24: ...s non de fa on limitative toute garantie implicite de valeur marchande ou de pertinence pour un usage particulier De plus le fabricant ne peut tre tenu responsable d aucun dommage accidentel sp cial o...

Page 25: ...ation 801 Business Center Drive Mount Prospect IL 60056 2179 Name_______________________________________________________________ Street Address________________________________________________________...

Page 26: ...orporation 801 Business Center Drive Mount Prospect IL 60056 2179 Nombre_____________________________________________________________ Direcci n_________________________________________________________...

Page 27: ...a requis pour une ventuelle r clamation au titre de la garantie Cette garantie n est pas transf rable Envoyer la carte de garantie seulement NE PAS ENVOYER L UNIT CETTE ADRESSE POUR R PARATION Envoyer...

Reviews: