2.0 Grinding
(
skip over this section if you have a Grinderless Unit
)
2.1 Grinder Operation
The Prot must be powered on at all times to operate the grinder
. The grinder
relies on an electromagnet interlock that engages the grinder drive train only when supplied with
power. The electromagnet is calibrated to disengage the interlock at set torque limit value to
prevent damage to the gear train. The grinder will only work if the two interlock switches are
engaged while the unit is powered on. One switch is engaged by the grinder lid, and the other
by the grinder drawer.
2.1.1 Grinder Safety
Please thoroughly review the safety precautions before operating the grinder. Failure to
do so may result in serious injury or irreparable damage to your device.
2.1.2 Grinder First Time Setup
Installing the Grinder Handle:
1. Remove the Grinder Crank Arm and Allen Key from the Accessories Box.
2. Use the Allen Key to remove the screw and washer from the Grinder Crank.
3. Place the support washer onto the crankshaft.
4. Install the Crank Arm over the hex on the Grinder Crank with the handle facing outwards
Note: the hex size is 5/16”.
5. Replace the screw with the washer under it, and tighten until snug.
Grinder Drawer Preparation:
1. Remove the Grinder Drawer from the side of the Prot
6