Figure 12
: How to grip the light guide shaft to adjust LED angle.
3.6.5 Step 3 - Calibrating the readings
1. Finally, we need to ensure the light guide readings are accurate. This is where we’ll use
the dowels. The procedure is the same for both the puller and nozzle sensor, with minor
differences that will be noted as required.
2. Place the ~1.83mm “dowel” in between the puller wheels as shown in Figure 13.
Similarly, check the nozzle sensor using your ~2.56mm dowel of choice. Do your best to
align the dowel with the nozzle output as seen in Figure 13.
Make sure the puller idler
wheel’s spring is attached! This will effectively position the dowel at the right
height as it squishes the puller wheel into position.
Figure 13
: The light guide alignment dowel positioned in between the puller wheels on the left,
and aligned with the nozzle on the right, in preparation for light guide alignment.