background image

www.sureheat.com

200319-01C

20

ELECTRICAL CONNECTION

FOR BLOWER KIT

 Do not use this heater if any 

part of it has been under water. 

Immediately call a qualified ser-

vice  technician  to  inspect  the 

heater and replace any part of 

the electrical system which has 

been under water.

GROUNDING INSTRUCTIONS

This heater is for use on 120 volts. The cord 

has a plug as shown at A in Figure 24. An 

adapter as shown at C is available for con-

necting three-blade grounding-type plugs to 

two-slot  receptacles. The  green  grounding 

lug  extending  from  the  adapter  must  be 

connected  to  a  permanent  ground  such  as 

a properly grounded outlet box. The adapter 

should not be used if a three-slot grounded 

receptacle is available.

Grounding Pin

Grounding Means

Metal Screw

Cover of

Grounded

Outlet Box

A

B

C

Adapter

Figure 24 - Grounded Electrical Outlet

ELECTRICAL WIRING

Any electrical re-wiring of this appliance must 

be done by a qualified electrician. This wiring 

must be done in accordance with local codes 

and/or in Canada with the current 

CSA C22.1 

Canadian Electrical Code

, and for US instal-

lations,  the 

National Electrical Code ANSI/

NFPA NO 70

.

  WARNING:  If  repairing  or 

replacing any electrical compo-

nent or wiring, the original wire 

routing, color coding and secur-

ing locations must be followed.

  CAUTION:  Label  all  wires 

prior  to  disconnection  when 

servicing controls. Wiring errors 

can cause improper and danger-

ous operation.

 WARNING: Never attempt to 

service heater while it is plugged 

in, operating, or hot. Burns and 

electrical  shock  could  result. 

Only a qualified service person 

should service or repair heater.

Verify proper operation after servicing. If any 

of the original wire as supplied with the appli-

ance must be replaced, it must be replaced 

with a wire of at least a 105º C temperature 

rating.

Motor

Black

Green

White

 Switch

Thermostat Switch

AUTO

O

MAN

(Sold 

Separately)

FAN OPERATION

To  operate  the  manual  unit,  turn  ON/OFF 

switch  to  the  ON  position.  To  operate  the 

Automatic unit, turn AUTO/O/MAN switch to 

the desired position. MAN position will remain 

constantly on. AUTO position will be controlled 

by the sensor on the fan blower unit. The sen-

sor will be activated when the temperature of 

the sensor head reaches the set point of the 

switch after the heater is started. To stop the 

operation, turn the switch to the O position.

Summary of Contents for IWH16NLTD-2

Page 1: ...y electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call t...

Page 2: ...ual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assist...

Page 3: ...er serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at hi...

Page 4: ...y a qualified service person should service and repair heater 10 Operating heater above elevations of 4 500 feet could cause pilot outage 11 To prevent performance problems do not use propane LP fuel...

Page 5: ...CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANSI Z223 1 NFPA 54 Available from American National St...

Page 6: ...VAPOR A BY PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by product of gas combus tion An unvented room heater produces ap proximately one 1 ounce 30 mL of water for every 1 000 BTUs 0 3 KWs of g...

Page 7: ...eathe Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from...

Page 8: ...grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These...

Page 9: ...igure 4 Mounting Clearances as Viewed From Front of Heater IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may...

Page 10: ...taching Mounting Bracket To Wall Use only the last hole on each end of mount ing bracket to attach bracket to wall Attach mounting bracket to a wall only in one of two ways 1 Attaching to wall stud Th...

Page 11: ...ns using 5 16 drill bit For solid walls concrete or masonry drill at least 1 deep 2 Fold wall anchor as shown in Figure 8 3 Insert wall anchor wings first into hole Tap anchor flush to wall 4 For thin...

Page 12: ...s firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks Figure 10 Mounting Heater Onto Mounti...

Page 13: ...void gas leak age for the gas not being used at the inlet of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheinsideoftheregu lator...

Page 14: ...ile pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tightening of the fitting Insta...

Page 15: ...the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane LP gas CAUTION Avoid damage to regulator Hold gas regulator with wren...

Page 16: ...lator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Sediment...

Page 17: ...Correct all leaks at once 6 Light heater see Lighting Instructions on page 18 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 19 1 Open equipment shuto...

Page 18: ...osition 4 Wait five 5 minutes to clear out any air Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you do not smell gas go to the next ste...

Page 19: ...e thermostat sensing bulb reacts to the temperature depending on housing construction TO TURN OFF GAS TO APPLIANCE Shutting Off Heater Turn control knob clockwise to the OFF position Shutting Off Burn...

Page 20: ...Code and for US instal lations the National Electrical Code ANSI NFPA NO 70 WARNING If repairing or replacing any electrical compo nent or wiring the original wire routing colorcodingandsecur ing loca...

Page 21: ...Turn Off Gas to Ap pliance page 19 see Troubleshooting pages 23 through 26 WARNING If yellow tipping occurs your heater could pro duce increased levels of carbon monoxide If the burner flame pattern...

Page 22: ...minutes 2 Remove four screws securing front panel 3 Pull front panel forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front pan...

Page 23: ...ife and require no further lubrication However periodic cleaning vacuuming of the appliance around the air intake and exhaust as well as the fan heater is recommended For heavy or continuous use perio...

Page 24: ...pment shutoff valve 2 Fully press in control knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Mai...

Page 25: ...t 1 Burner orifice is clogged 2 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 22 2 Contact local gas supplier Delayed ignition of burner s 1 Manifold pressure is t...

Page 26: ...products Heater produces un wanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANTstatement page23 2 Gas leak See Warning State ment at the top of page 23 3 Low fuel sup...

Page 27: ...ontact your local gas supplier REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Call Customer...

Page 28: ...www sureheat com 200319 01C 28 7 5 6 12 18 17 2 11 3 9 8 1 16 10 14 13 15 4 19 20 PARTS MODELS IWH16NLTD 2 AND IWH26NLTD 2 IWH26NLTD 2 Shown...

Page 29: ...1 5 Burner Assembly 1 6 161139 05 161139 05 ODS Pilot 1 7 Dual Fuel Regulator 1 8 161200 01 161200 01 Inlet Cover Plug 1 9 160960 01 160960 01 Cap with Seal 1 10 Bezel T stat Control 1 11 Reflector As...

Page 30: ...____________________ ________________________________________________________________ ________________________________________________________________ _________________________________________________...

Page 31: ...____________________ ________________________________________________________________ ________________________________________________________________ _________________________________________________...

Page 32: ...ge resulting from any of the following Negligent use or misuse of the product including exposing the product to chemicals or cleaning products not approved by SHM International Corp Corrosion rust or...

Reviews: