Figure 5 - Removing Front Panel
INSTALLATION
1. Remove 4 screws securing front panel.
2. Carefully slide front panel forward.
FASTENING HEATER TO WALL
REMOVING FRONT PANEL
INSTALLING THERMOSTAT SENSING BULB (OPTIONAL)
(For Heaters with Blower Installed Only)
1. Carefully remove bulb clips with ther-
mostat sensing bulb from the shipping
position in the back panel.
2. Slide thermostat sensing bulb out of the
2 clips.
3. Carefully route thermostat sensing bulb
out of shipping position hole in the back
panel and into the relocation position hole.
If necessary, loosen wiretie securing capil-
lary. DO NOT kink capillary.
Mounting Bracket
The mounting bracket is located on back panel
of heater. It has been taped there for shipping.
Remove mounting bracket from back panel.
Methods For Attaching Mounting
Bracket To Wall
Use only the last hole on each end of mount-
ing bracket to attach bracket to wall. Attach
mounting bracket to a wall only in one of two
ways:
1.
Attaching to wall stud:
This method pro-
vides the strongest hold. Insert mounting
screws through mounting bracket and into
wall studs.
2.
Attaching to wall anchor:
This method
allows you to attach mounting bracket to
hollow walls (wall areas between studs)
or to solid walls (concrete or masonry).
Decide which method better suits your needs.
Either method will provide a secure hold for
the mounting bracket.
Screw
Front
Panel
Figure 6 - Moving Thermostat Sensing Bulb
Thermostat
Sensing
Bulb
Shipping
Location
Route
Thermostat
Sensing
Bulb into
Hole
Thermostat Sensing Bulb Relocation Position
Bulb Clip
Capillary
Thermostat Sensing Bulb
4. Insert bulb clips into 2 rectangular slots
parallel to the bottom of heater (relocation
position). Slide thermostat bulb through
clips. If clips are damaged use clips lo-