background image

SmokeSight SS10LNAN V0.5 

Page 1 

 

 

SmokeSight Residential Smoke Alarm 

By Redbusbar 

Part Number:  SS10LNAN 
Description: 

10 Year Lithium Battery Power Photoelectric Smoke Alarm with Option Card 

PLEASE LEAVE THESE INSTRUCTIONS WITH THE OCCUPANT, TO BE RETAINED FOR THE LIFE OF THE ALARM. 

Read all Instructions before Installation and Operation 

Regular testing of this smoke alarm is necessary to ensure the unit is functional and that the battery is in good 
condition. It is recommended that the smoke alarm be replaced after 10 years of normal service. The only user-
serviceable parts are the Option Card batteries. Refer to ‘Replacing the Backup Batteries’.  

 

EQUIPMENT INSTALLATION HAZARD 
• This product must only be used for the purpose described in these instructions and must be installed in accordance 
with the local regulations. 
• Ensure that the product has been correctly installed and tested for safe operation. 
• Smoke Test each interlinked alarm. Check to ensure every interlinked alarm, alarms correctly. If any unit fails to 
alarm, refer to ‘Troubleshooting’  

Failure to follow these instructions may result in equipment damage or injury.

 

 

Smoke Alarm – Top View 

 

Smoke Alarm – Bottom View 

 

1.

 

Option Card 
(White) LED 

2.

 

Alarm (Red) 
LED 

3.

 

Smoke Alarm 
Power Switch 

4.

 

Option Card 
Battery Holder 

5.

 

Option Card 
Configuration 
Switches 

 

 

 

 

Mounting Base – Top View 

 

Mounting Base – Bottom View 

 

6.

 

Locking Tab 

7.

 

Tamper Clip 

 

Summary of Contents for SS10LNAN

Page 1: ...ries Refer to Replacing the Backup Batteries EQUIPMENT INSTALLATION HAZARD This product must only be used for the purpose described in these instructions and must be installed in accordance with the l...

Page 2: ...cation Status Alert Escape White LED Audible Indication Alert 50dBA at 3m Battery Low Chirp Locations This smoke alarm can be used in all residential homes and apartments and positioned in accordance...

Page 3: ...g base by twisting it back and forth until it breaks loose 2 Screw the mounting base onto the ceiling or wall using appropriate fasteners Screw diameter 8gauge 4mm 3 If the Radio Interlink feature is...

Page 4: ...us configuration modes the option card functions can be configured Option card status requests and configuration commands are made using sequential quick taps on the Test Hush button Responses from th...

Page 5: ...witch ON 3 Spare 4 Return to Operation Mode 5 5 Return to Factory Defaults Radio Interlink Configuration Mode Command Taps Description Response White LED Flashes Beeps 0 Radio Interlink Configuration...

Page 6: ...hes Beeps Perform a Return to Factory Defaults on the lost slave alarm s 2 White LED Flashes Beeps and remove their option card batteries Then re add them to the network using the Add Radio Node proce...

Page 7: ...this procedure if your network is not functioning correctly and it is not convenient to perform individual Return to Factory Defaults on each smoke alarm eg the smoke alarms are mounted on a high ceil...

Page 8: ...rm and each subsequent alarm on your network taking care to only apply power to each alarm following confirmation that the previously powered alarm has joined the network as a slave 4 Once all alarms...

Page 9: ...tory default test settings are every two weeks from the day and time that the option card is first supplied with power Continue with the following steps only if you wish to change Auto Test times 2 Se...

Page 10: ...ert small children in the home 2 Leave immediately by your plan of escape Don t waste time getting dressed or picking up valuables 3 When leaving don t open any inside door without first feeling its s...

Page 11: ...ity is too high even in low sensitivity mode for the Hush feature to activate Smoke alarm is sounding it stops when Test Hush is pressed Low sensitivity mode has been activated for 9mins Make sure you...

Page 12: ...arm can be vacuumed or brushed with a soft brush to remove dust dirt or kitchen grease that has accumulated ALWAYS TEST THE SMOKE ALARM AFTER CLEANING If the smoke alarm is defective in any way do not...