8.0 Specifications

Power supply: .................. 12VDC to 30VDC 300mA (idle/maximum current draw 150mA) tip positive 
Output: .................................................................................................. Stereo RCA 500mV nominal 
MP3 sample rate: ...................................................................................................................... 44kHz 
SD card size: .............................................................................................................. 256MB to 16GB 
Trigger activation: ......................................................................................................Closing contact 
Switched output: ............................................................... 12-30VDC out (supply voltage dependant) 

MP3 info: 

Length/size: ................................ Limited by card size (800mins @ 128kbps, 44kHz on supplied 8GB) 
Bit rate: .................................................................. All standard MP3 rates (128kbps recommended) 
Sample rate: ............................................................... All standard MP3 rates (44kHz recommended) 
Channels: .................................................................................................................. Stereo or mono

 

* Specifications subject to change without notice.

7.0 Troubleshooting

NO Power (Power LED does not illuminate): 

Check power supply DC jack is 2.1mm and not 2.5mm size. 
Power supply voltage is 12-30VDC. 
Power supply is a DC output, not AC. 

Message active 10 LED flashs all the time: 

This is an indicator that the SD card is not inserted correctly or is not formatted. Make sure all folders 
on the SD card are as per figure 6.

Emergency tones do not work: 

Switch DIP switch 2 ON to activate emergency tones. 

Summary of Contents for A 1741

Page 1: ...they activate This reduces the chance of accidental triggering Switched output The switched output terminal is triggered when any zone is activated The voltage is the same as the power supplied to the...

Page 2: ...es and Indicators These switches are used to trigger the Alert and Evacuation tones which conform to AS1670 4 The LED s inside the switches indicate when the associated message is playing The tones ca...

Page 3: ...ave a common ground 6 Message 1 8 Triggers The message triggers are activated by closing contacts on the rear of the unit whether by a normally open switch or a timer or controller The triggers can be...

Page 4: ...r Cancel switch is used A momentary closing contact on the Cancel trigger or closure of the Cancel switch will stop the MP3 playing it is recommended that the Cancel contact or switch be held up to 2...

Page 5: ...ll need a PC equipped with a SD card reader to do this not supplied Step by step guide to put a MP3 into Trigger1 with a Windows installed PC Step 1 Make sure the PC is on and card reader connected an...

Page 6: ...s MP3 file needs to be deleted and replaced by the MP3 file you want to play when you activate trigger1 The MP3 file name is not important only that there is one MP3 file in the trig1 folder Make sure...

Page 7: ...h settings The Alert tone comes with a change over option which forces the A 1741 to switch from Alert to the Evacuation tone after a prescribed time Use DIP switches 5 8 to adjust this time or switch...

Page 8: ...ard MP3 rates 128kbps recommended Sample rate All standard MP3 rates 44kHz recommended Channels Stereo or mono Specifications subject to change without notice 7 0 Troubleshooting NO Power Power LED do...