SPECIFICATIONS
Part Number
DPS1225
DPS1240
DPS2410
DPS2420
Input Voltage Range
9 to 32 V
Recommended Input Fuse
*1
40 A
(REDARC FK40
recommended)
60 A
(REDARC FK60
recommended)
40 A
(REDARC FK40
recommended)
60 A
(REDARC FK60
recommended)
Nominal Output Current Rating
25 A
40 A
10 A
20 A
Surge Current Rating
50 A
80 A
20 A
40 A
Recommended Output Fuse
*1
40 A
(REDARC FK40
recommended)
60 A
(REDARC FK60
recommended)
40 A
(REDARC FK40
recommended)
40 A
(REDARC FK40
recommended)
No Load Current
< 100 mA
< 200 mA
Standby Current
< 5 mA
Output Voltage
(selected with Orange wire)
No Connection
12.0 V
24.0 V
Earth
13.7 V
27.4 V
Positive supply
14.5 V
29.0 V
Line & Load Regulation
± 1%
Conversion Efficiency
> 94%
Operating Temperature
–50°C to +50°C (–58°F to +122°F)
Weight
680 g (24 oz)
Dimensions
150 × 120 × 37 mm (5.9 × 4.7 × 1.5")
Standards
CE, C-Tick, AS/NZS CISPR1 1:2004
Warranty
2 Years
*1. Please refer to FUSING below.
Voltage tolerance of ±0.12 V.
3
FUSING
REDARC recommend using MIDI style bolt down fuses as they
ensure a low resistance connection. The REDARC FK40 and FK60
fuse kits are recommended.
Blade type fuses are not recommended as they can result in a high
resistance connection which causes excess heat and may damage
the fuse holder and/or the wiring. Self-resetting circuit breakers
are not recommended as they may trip prematurely and continue
to cycle until failure, due to the heat generated by the current
flowing through the wires.