P
UB
.
42004-472B
A
UTO
-D
IAL
T
ELEPHONE
M
ANUAL
P
AGE
29 of 33
f:\standard ioms - current release\42004 instr. manuals\42004-472b.doc
01/15
Table 11. Programming Documentation Table
Function
Key Sequence
Default
Settings
User Settings
Auto-dial or Ring-Down Programming (see Table 3 on page 23)
CALL
Button Auto-dial Number 1
DD
*1
*123456789*0#
CALL
Button Auto-dial Number 2
DD
*2
None
CALL
Button Auto-dial Number 3
DD
*3
None
Primary Dial Tone Delay
#10
NN
3
seconds
Secondary Line Dial Tone Delay
#11
NN
2
seconds
Ring-down Operation
*1
None
Password Protection Feature Programming (see Table 4 on page 24
)
#14
NNNN
2468
Disconnect Options Programming (see Table 6 on page 25)
Emergency Push-button Disconnect
#17
L
1
(enabled)
Call Time-out Disconnect
#12
NN
10
minutes
Dial Tone Disconnect
#19
L
0
(disabled)
ADA Programming (see Table 7 on page 26)
DTMF Disconnect Option
#18
L
1
(enabled)
Identification Code Entry
#13
LNNN
None
Other Programming Features
Auto-Answer Alert Feature
(see Table 5 on page 24)
#16
L
0
(disabled)
Extended Strobe Operation
(see Table 8 on page 26)
NN
…*8
#26
NNN
90125
#26050 (5 sec.)
Output 4 Control Setup
(see Table 9 on page 27)
#25
NNN
0 0 0 (disabled)
Early Microphone Option
(see Table 10 on page 28)
#71
L
0
(disabled)
Table Legend
D = DTMF digit 0–9, *, or #
N = Numeric digit 0–9 L = 0-Disable, 1-Enable