Programming Sequence
The following command sequences are common to both “remote” and “local” programming and are used
to configure the telephone to the desired operating parameters.
1.
Dial the factory-default password
2468
(or appropriate customer-selected password). A success tone
(short beep) is generated to indicate that “standard” programming mode has been accessed.
2.
After hearing the password success tone, begin entering each desired programming key sequence. A
success tone (short beep) is generated each time a new key sequence is accepted. An error tone (two
low tones) is generated to indicate an error. If an error tone is generated, verify the key sequence and
enter the sequence again.
3.
To terminate the programming call:
a.
Remote – Place the programming telephone on hook. The RED ALERT
®
telephone will
automatically end the programming call within 20 seconds.
b.
Local – Press the
CALL
push button (whichever is connected to J1) to end the call. Restore
any moved push-button harness connectors to their original position (if necessary).
N
OTES
:
1.
The RED ALERT
®
telephone will automatically time out and disconnect if 20 seconds elapses
between digit entries, or if an invalid password is entered.
2.
If DTMF digits have not been dialed within 3 seconds of the first success tone, the telephone will exit
programming mode and revert to a standard voice call.
3.
If the password success tone is not generated, the telephone has failed to recognize the password.
Therefore, the telephone must then be programmed with the password disabled. Refer to the
“Password Disabled Programming” section on page 21.
Password Disabled Programming
The programmable features of the RED ALERT
®
Auto-Dial Telephones are protected by a factory default
or user specified password, as previously described. Situations may arise when a setting change is
required but the password is forgotten or unknown. To permit continued programming support in this
situation, converting to Password Disable Programming may be necessary and is described as follows:
1.
Access the telephone’s PCBA and disable the password protection feature by changing jumper J9 to
the “DIS” position.
2.
Confirm the auto-answer feature is enabled (jumper J14 should be in the “EN” position).
3.
Using a touch-tone telephone, call the RED ALERT
®
Telephone. The telephone will automatically
answer the call and will generate a splash tone (low to high sequence) followed by a success tone
(single beep).
4.
Begin entering the desired key sequences as previously described, following steps 2 and 3 in the
“Programming Sequence” section on page 21.