Use the REDLINK™ Bridge with a RED

®

 T.H.C. (Tactical Hand Controller) to control Canon

®

 and Nikon

®

 lenses.

When used with the REDLINK Bridge, the RED T.H.C. can perform the following:

 

Control Focus and Iris for Canon and Nikon lenses

 

Set Focus and Iris lens limits for Canon and Nikon lenses

 

Initialize remotely

This chapter explains how to pair the T.H.C. with the REDLINK Bridge, as well as how to control Focus and Iris 

with the T.H.C. 
For detailed instructions for using all components of the RED 3-Axis Lens Control System, see the 

RED 3-Axis 

Lens Control System Operation Guide

, available at 

www.red.com/downloads

NOTE: 

In order to use the T.H.C. with the REDLINK Bridge, the T.H.C. must be on firmware v703 or later. To 

download T.H.C. firmware, go to 

www.red.com/downloads

.

PAIR THE T.H.C. WITH THE REDLINK BRIDGE

You can pair the T.H.C. with the REDLINK Bridge using either a wired or unwired connection. This section de-

scribes both methods.

PAIR THE T.H.C. WITH THE REDLINK BRIDGE WIRELESSLY

1.  Dock the REDLINK Bridge to the DSMC

®

.

2.  Power off the T.H.C. by toggling the power switch to 

Cable

 mode.

3.  Press and hold the 

Focus Limit

 button, and toggle the power switch to 

Battery

 mode.

The Focus and Iris LEDs alternate flashing in a ping-pong manner.

4.  After a few seconds, release the 

Focus Limit

 button.

The Iris Limit and Focus Limit LEDs flash to tell you what the current channel is:

 

Iris Limit LED

: Flashes to represent the tens.

 

Focus Limit LED

: Flashes to represent the ones.

For example, if the Iris Limit LED flashes twice, and the Focus Limit LED then flashes once, then the chan-

nel is currently 21.

CONTROL LENSES VIA 

REDLINK BRIDGE

Summary of Contents for REDLINK BRIDGE

Page 1: ...REDLINK DEVELOPMENT KIT LENS CONTROL RED COM REDLINK BRIDGE O PERAT ION GU IDE ...

Page 2: ...INK Bridge 11 Dock the REDLINK Bridge 11 Undock the REDLINK Bridge 12 Power the REDLINK Bridge 12 Chapter 4 Connect REDLINK Bridge to an App 13 Chapter 5 Control Lenses Via REDLINK Bridge 17 Pair the T H C with the REDLINK Bridge 17 Set Up Focus and Iris Control 19 Initialize Lens with the T H C 20 Additional T H C Operations 20 Chapter 6 REDLINK Bridge Maintenance 21 Clean System Components 21 Ch...

Page 3: ... 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est sus ceptible d en compromettre le fonctionnement Cet appareil numéri que de la classe B est conforme à la norme NMB 003 du Canada FEDERAL COMMUNICATIONS COMMISSION FCC STATE MENTS This equipment has been tested and found to comply with the limits for a Class B digital de vice pursuant to par...

Page 4: ...e Waste Electrical and Electronic Equip ment WEEE mark applies only to countries within the European Union EU and Norway This symbol on the product and accompany ing documents means that used electrical and electronic products should not be mixed with general household waste For proper treatment recovery and recycling please take this product to designated collection points where it will be accept...

Page 5: ...e range 20 C to 50 C 4 F to 122 F If there are any performance issues with your camera or acces sories when operating within this temperature range please file a support ticket on support red com The SIDE HANDLE SIDE SSD Module Rear Modules and Lens Mount are NOT HOT SWAPPABLE meaning you cannot re move or install them while the camera is powered on Before installing or removing any of these acces...

Page 6: ...e used as part of the RED 3 Axis Lens Control System to wirelessly operate the focus and iris motors in supported Canon and Nikon lenses In this scenario the REDLINK Bridge assumes the role of the RED W M D Wireless Motor Driver while the RED T H C Tactical Hand Controller remains the wireless remote The REDLINK Bridge is capable of supporting wireless communication up to a range of approximately ...

Page 7: ...ROL The T H C must be on firmware v703 or later The Canon or Nikon lens must be electronically supported by the DSMC The DSMC must be on firmware v5 2 8 or later ADDITIONAL RESOURCES The following resources offer additional information about RED RED ROCKET X and the RED community RED com Check the official RED website for the latest information about RED products RED Learn Articles RED offers in d...

Page 8: ...5 0064 REV D 8 02 REDLINK Bridge CONNECTOR 1 CONNECTOR DESCRIPTION 1 AUX 6 pin 0B LEMO Connect the REDLINK Bridge to a T H C for wired pairing COMPATIBLE CABLE 790 0444 REDLINK to T H C Connector Cable 3 REDLINK Bridge Connector REDLINK Bridge CONNECTOR AND LEDS ...

Page 9: ...GE OPERATION GUIDE COPYRIGHT 2015 RED COM INC 955 0064 REV D 9 6 PIN 0B LEMO AUX CONNECTOR PINOUT 1 6 3 4 5 2 6 PIN 0B LEMO AUX CONNECTOR PIN SIGNAL 1 GND 2 Rx 3 Tx 4 Pwr Out 5 Pwr In 6 6 Pin 0B LEMO AUX Connector ...

Page 10: ...red off and turned off Green The REDLINK Bridge is powered The DSMC is powered on and turned on Amber The camera is upgrading REDLINK Bridge firmware Link Indicator LED Off Wireless disabled Green Connected to wireless access point Ad hoc network connection available Green flashing The camera is upgrading REDLINK Bridge firmware Amber Searching for wireless access point Red Error REDLINK Bridge LE...

Page 11: ...ning you can remove or install the module while the cam era is powered on DOCK THE REDLINK Bridge 1 Slide the REDLINK Bridge over the V Mount on the back of the DSMC BRAIN or compatible rear mod ule You will hear a click which indicates that the REDLINK Bridge is securely attached The REDLINK Bridge is automatically powered when connected Dock the REDLINK Bridge INSTALL THE REDLINK Bridge ...

Page 12: ... REDLINK Bridge 1 Press the release buttons on both sides of the REDLINK Bridge and slide the module upward 2 Remove the REDLINK Bridge POWER THE REDLINK Bridge The camera automatically powers the REDLINK Bridge when the REDLINK Bridge is connected to the camera and the camera is powered ...

Page 13: ...cess point and communi cate through that wireless network CONNECT VIA AD HOC MODE In Ad Hoc mode the REDLINK Bridge and your device connect to each other To connect the REDLINK Bridge to your device via an ad hoc network follow the instructions below 1 Dock the REDLINK Bridge to the DSMC 2 Go to Menu Settings Setup Communication 3 Select the WiFi tab 4 Select the Enable WiFi check box 5 Select Ad ...

Page 14: ... format only 0 9 A F 9 Close the WiFi screen 10 Connect your device to the ad hoc network created by the REDLINK Bridge The steps in this procedure depend on what type of device and operating system you are using For example if you are connecting an iOS device go to Settings Wi Fi Devices and select the camera name The camera is identified by the SSID which also displays on the WiFi screen in came...

Page 15: ...nd password for the network since you will need that information to connect the DSMC to the same network 3 Dock the REDLINK Bridge to the DSMC 4 Go to Menu Settings Setup Communication 5 Select the WiFi tab 6 Select the Enable WiFi check box 7 Select Infrastructure 8 Select Scan to search for available wireless networks The available wireless networks access points their encryption types and their...

Page 16: ...access point displays at the bottom of the WiFi screen after the REDLINK Bridge connects to the access point 12 Connect your device to the same wireless network that the DSMC is connected to The steps in this proce dure depend on what type of device and operating system you are using For example if you are connecting an iOS device go to Settings Wi Fi and select the wireless network The DSMC and y...

Page 17: ... H C must be on firmware v703 or later To download T H C firmware go to www red com downloads PAIR THE T H C WITH THE REDLINK BRIDGE You can pair the T H C with the REDLINK Bridge using either a wired or unwired connection This section de scribes both methods PAIR THE T H C WITH THE REDLINK BRIDGE WIRELESSLY 1 Dock the REDLINK Bridge to the DSMC 2 Power off the T H C by toggling the power switch t...

Page 18: ...nects to the channel 9 In the DSMC menu go to Menu Settings Setup Motor Control 10 Select the Wireless tab 11 Select the Enable Wireless Controller check box 12 Select the channel from the Channel drop down menu The default is Channel 1 and you can select one out of 42 channels 13 Select the strength of the wireless signal from the Power drop down menu Low The low power setting balances range and ...

Page 19: ...wn menu The default is Channel 1 and you can select one out of 42 channels 11 Select the strength of the wireless signal from the Power drop down menu Low The low power setting balances range and low power and is appropriate in most cases High For maximum range the high power setting can be used NOTE Be sure to set wireless signal power appropriately If the wireless signal power is set to High the...

Page 20: ... The lens is not behaving as expected The focus or zoom was manually changed The focus range was changed using the focus range limiter switch on the lens only applicable to multi focus zone lenses NOTE Failing to perform the initialization sequence after any of the situations listed above may result in unde fined behavior INITIALIZE 1 Press and hold the Initialize button on the T H C for two 2 sec...

Page 21: ...e parts inside Alteration or repairs made to the REDLINK Bridge except by a RED authorized service facility will void the Limited Warranty CLEAN SYSTEM COMPONENTS Clean ONLY using a dry cloth When cleaning your REDLINK Bridge remember that the components are not waterproof and moisture can damage electronic circuitry WARNING DO NOT rinse or immerse any part of the REDLINK Bridge Keep components dr...

Page 22: ...ed by any RF interference that may be in your area LENS CONTROL CANNOT CONNECT T H C TO REDLINK Bridge SYMPTOM Cannot connect a T H C Tactical Hand Controller to the REDLINK Bridge POTENTIAL RESOLUTIONS You can only connect one T H C to the REDLINK Bridge at a time Ensure that the REDLINK Bridge is dis connected from any T H C before connecting a new one Ensure that the T H C is running the most r...

Page 23: ...he lens POTENTIAL RESOLUTIONS Ensure that the switch on the side of your lens is set to autofocus The switch label depends on the type of lens Canon Switch to AF Nikon Switch to M A In the DSMC menu go to Menu Focus and ensure that Manual is selected from the Mode drop down menu The lens function Focus or Iris may be locked For information about how to remove a lens lock see the RED 3 Axis Lens Co...

Page 24: ...ht w o antenna 4 32 11 cm Width 2 95 7 5 cm Depth 1 06 2 7 cm Weight 0 477 lbs 216 g Material Aluminum Construction Machined Coating Black anodized coating Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 20 C to 50 C 4 F to 122 F Operating Humidity Range 0 to 85 non condensing Storage Humidity Range 0 to 85 non condensing Typical Operating Power Dissipation 220 mA Peak Operatin...

Page 25: ...E OPERATION GUIDE COPYRIGHT 2015 RED COM INC 955 0064 REV D 25 REDLINK Development Kit PACKAGING SPECIFICATION DESCRIPTION Dimensions Height 7 00 17 78 cm Width 6 50 16 51 cm Depth 2 50 6 35 cm Weight 0 75 lbs 340 g ...

Page 26: ...r Module Pro Battery Module Dual Pro Battery Module Quad Pro I O Module SUPPORTED LENSES You can use the REDLINK Bridge with the T H C Tactical Hand Controller to control the Focus and Iris of any Canon and Nikon lens that is electronically supported by RED For a full list of lenses that are supported see the DSMC Operation Guide available at www red com downloads B REDLINK Bridge COMPATIBILITY ...

Page 27: ... All trademarks trade names logos icons images written material code and product names used in associa tion with the accompanying product are the copyrights trademarks or other intellectual property owned and controlled exclusively by RED COM INC ...

Reviews: