31
19-CLEANING AND MAINTENANCE
Technical Dept. - All rights reserved - Reproduction prohibited
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualified personnel whose technical expertise
includes combustion and electricity.
We recommend that an annual maintenance service is carried out (with a scheduled service contract). This service is essentially a visual
and functional inspection of the internal components. The following is a summary of the checks and/or maintenance that are essential for
the correct operation of the product.
• Gear motor
• Smoke extractor fan
• Smoke probe
• Ignition spark plug
• Pellet/water automatic rearm thermostat
• Room/water temperature probe
• Motherboard
• Fuses protecting panel-motherboard
• WIRING
PARTS/INTERVAL
2-3 DAYS
7 DAYS
30 DAYS
60-90 DAYS
1 YEAR
UNDER THE
USER'S
RESPONSIBILIT
Y
Brazier*
·
Ash pan
·
Glass
·
Lower compartment
·
Turbulators
·
BY THE
QU
ALIFIED TECHNICIAN
Complete exchanger
·
Smoke duct
·
Door gasket
·
Internal parts
·
Flue
·
Circulation pump
·
Plate heat exchanger
·
Plumbing components
·
Electro-mechanical components
·
Overpressure silicon damper for combustion
chamber
·
Door closure operation
·
* THE FREQUENCY OF CLEANING SHOULD BE INCREASED IF THE PELLETS ARE OF POOR QUALITY.
•