18
16-MENU ITEMS AND OPERATION
SYSTEM WITH: PELLET STOVE, PUFFER AND EMERGENCY BOILER (WALL-MOUNTED)
Adjustable setting
SET
VALUES
PUFFER TEMP.
55°C - 75°C
Parameters to be set
Settings
Value
Configuration
5
Auxiliary Boiler
ON
Hydraulic diagram
Num.
Description
Num.
Description
1
Pellet Boiler
7
Plate heat exchanger
2
Rear terminal block
8
System pump
3
Anti-condensation valve
9
Emergency boiler thermostat
4
Puffer
10
Activation relay
5
Puffer Probe
11
Auxiliary boiler connection module
6
Emergency boiler
12
Non-return valve