50
EN
5 - TECHNICAL FEATURES
The pellets must be transported and stored in dry conditions. If they are stored when damp they dilate. The pellets must therefore be
protected against humidity during transport and storage until they are used for combustion.
PELLET/AIR PIPE
There are two types of pipe required to connect the Logika Refill boiler and the Big Bag or any other type of storage tank: the pellet pipe
and the air pipe.
PELLET PIPE (T2)
The pellet pipe is made of rigid and shockproof plasticised PVC, with a copper wire inside for earth connection.
Characteristics:
SELF-EXTINGUISHING IN COMPLIANCE WITH UL 94 V2
INTERNAL DIAMETER
50 mm
EXTERNAL DIAMETER
60 mm
WEIGHT
0.9 kg/m
OPERATING TEMPERATURE
-5°C + 60°c
MINIMUM BENDING RADIUS
250 mm
MAX OPERATING PRESSURE
23°C 4 bar
VACUUM
6 m H2O
AIR PIPE (T1)
The pipe is made of plasticised PVC
with a PVC rigid and shockproof coil:
Characteristics:
SELF-EXTINGUISHING IN COMPLIANCE WITH UL 94 V2
SMOOTH INTERNAL SURFACE
LIGHT AND FLEXIBLE
INTERNAL DIAMETER
50 mm
WEIGHT
0.44 kg/m
OPERATING TEMPERATURE
-10°C + 60°c
MINIMUM BENDING RADIUS
250 mm