27
4-OPERATION
CONTROL PANEL DISPLAY
CONTROL PANEL LOGIC
Some useful information is provided below to understand the logic and use of the control panel:
t
Knob
A
sets 5 levels of ventilation. The knob turns smoothly from min to max.
t
Knob
B
allows the room temperature to be set. The temperature ranges from a min of 15°C to a maximum of 30°C and even in this
case, the knob turns smoothly.
t
Knob
C
sets 5 flame levels (power); the key turns smoothly.
t
The product is switched on and off via key
D
.
t
The pellet load is increased or decreased via key
E
wit respect to the default setting that is equal to 0. When the product is switched
on for the first time, the set value is 0 (the LED in the middle). The pellet load can be increased via key E (LED to the right +1/+2) or
decreased (LED to the left -1/-2). The selected LED will remain orange while the appliance works and will go off when the product is
switched off. The last setting will be saved in the memory for the next start-up.
t
Led 1
– descriptions.
Fixed Green
– the product is on
.
Flashing Green
– the product is on or being set.
Flashing Orange
– the product is off (even due to ECO-STOP).
Flashing Red + buzzer
– an alarm has been triggered.
Flashing Orange/Green
– on stand by due to ECO-STOP
.
t
The 5
LEDs
above key
E
(0/-1/-2/+1/+2) are activated to indicate the type of alarm and the pellet loading type selected.
LEGENDA
A. Fan adjustment knob.
B. Temperature adjustment knob.
C. Power adjustment knob.
D. ON/OFF key.
E. Pellet loading key
LED 1. Multi-coloured LED ON/OFF.
LEDs -2/-1/0/+1/+2 Pellet loading level or alarm alert.
Technical Dept. - All rights reserved - Reproduction is prohibited