Red Valve Company SERIES 5400 Installation, Operation And Maintenance Manual Download Page 1

IMPORTANT
Please take a moment to review this manual. Before performing any maintenance on the
valve be sure the pipeline has been de-pressurized.
  The improper installation or use of this
product may result in personal injury, product failure, or reduced product life.  Red Valve Co., Inc.
can accept NO liability resulting from the improper use or installation of this product.  If you have
any questions or problems, please call the customer service department at (412) 279-0044. We
appreciate your comments.  And thank you for choosing Red Valve.

The Red Valve Series 5400 Control Pinch Valve  is a
bi-directional valve designed for tough slurry appli-
cations. The elastomer sleeve closes on centerline,
creating a smooth venturi which reduces wear. The
flexing action of the sleeve breaks up any sediment
or build-up in the valve, which makes the Series
5400 a reliable, low maintenance control valve.

A variety of elastomers are available to suit your
specific needs. Along with the standard Red Valve
sleeve, we offer Cone, Variable Orifice, Reduced Port,
and Double Wall sleeves for special applications.

• Simple design
• No packing to maintain, ever
• Cost effective
• No cavities or dead spots to bind
  valve operation
• Low maintenance

SERIES 5400 CONTROL VALVE

WITH BEVEL GEAR ACTUATOR

Installation, Operation, and Maintenance Manual

Page 1 of 8

Summary of Contents for SERIES 5400

Page 1: ...400 Control Pinch Valve is a bi directional valve designed for tough slurry appli cations The elastomer sleeve closes on centerline creating a smooth venturi which reduces wear The flexing action of t...

Page 2: ...me Steel frame that provides the pivot points for the scissor mechanism and mounting point for the actuator 6 Side Rod Pins One pin for each side rod threaded on each end 7 Pivot Pins Two pins similar...

Page 3: ...longer represents the stroke length of the valve Returns All returns must have standard Red Valve Company return goods tags Sleeves to be inspected by the Red Valve Company must have the tag firmly at...

Page 4: ...ion site Only qualified personnel should handle the electrical connections Be sure to refer to the actuator manufacturer s IOM for proper safety precautions Reversing positive negative connections or...

Page 5: ...causing damage to the valve 4 MAINTENANCE Red Valve Company recommends lubricating the stem where it is attached to the bevel gear internals every 90 days The protective cover should be removed and t...

Page 6: ...ed for any reason it is important that it is re assembled in the correct order See Fig E 1 Place Mounting Frame 5 onto the top of the valve body If pattern of small holes in the bottom plate does not...

Page 7: ...Fig E 2 2 1 12 12 3 3 10 10 10 11 6 7 6 5 7 9 9 4 4 12 8 Page 7 of 8 See Page 2 of 8 for parts list...

Page 8: ...ith upon its discovery or use and possession thereof after an attempt has been made and completed to remedy defects therein or failure to return product or part for replacement as herein provided or f...