Test method 3: dynamic measurement with a rotary torque transducer on the actual application.
LED indicator and beeper on the tool shows the following status:
Status of the LED indicator and
beeper
Status of the tool
Action to be taken
Light up in red, yellow and green
together for one scond.
A long beep for one second.
The motor is switched on
-
Light up in red for one second.
A long beep for one second.
The preset torque is not reached
(NOK).
The screwing fastener must be
performed again.
Light up in red for one second.
A long beep for one second.
The screw is refastened after
fastening (NOK).
The screwing fastener must be
performed again.
Light up in green.
The preset torque is reached and
the tightening is OK.
-
Blinks in yellow for five times.
Five short beeps
The battery power becomes low
Replace the battery with a fully
charged one
Light up in yellow for five seconds.
A long beep for five seconds
The battery power is used up, the
tool stops immediately.
Replace the battery with a fully
charged one.
Light up in blue.
The tool is in reverse operation
-
Blinks in red for two times
The motor is too hot
Remove the battery and let the
tool cool down, and then reattach
the battery. The tool can work
properly again.
Blinks in red for three times.
The motor has failed.
Send to the service center.
Blinks in red for four times
The connector wire has failed.
Send to the service center.
Left – Right rotation:
For left rotation: push the F/R button, blue light > tool is in left rotation. Push F/R button again for right rotation.
Automatically switching back from left to right rotation: push the F/R button for 5 seconds until the blue LED blinks once, now the tool
rotates one cycle in left direction and after stopping the tool switches automatic to the right rotation. Deactivating: holding the F/R
button again for 5 seconds until the blue LED blinks once.
RPM setting pistol model:
With the "Programmer" the rpm of the motor can be adjusted, see manual of the Programmer.
Maintenance:
Check the tool regularly for loose bolts/screws or parts.
In case of power loss: Have the tool repaired.
Only trained and qualified engineers are allowed to adjust or repair the tool.
In case of disposal of the tool, follow local regulations, so as much as possible can be recycled. Do not throw it in the normal waste bin.