red lion Sixnet ST-IPm-8460 Hardware Manual Download Page 1

Hardware Guide | April 2020

LP1106 | Revision B

Sixnet

®

 Series

ST-IPm-8460  

SixTRAK IPm

®

 RTU/Controller

Summary of Contents for Sixnet ST-IPm-8460

Page 1: ...Hardware Guide April 2020 LP1106 Revision B Sixnet Series ST IPm 8460 SixTRAK IPm RTU Controller...

Page 2: ...York PA 17406 CONTACT INFORMATION AMERICAS Inside US 1 877 432 9908 Outside US 1 717 767 6511 Hours 8 am 6 pm Eastern Standard Time UTC GMT 5 hours ASIA PACIFIC Shanghai P R China 86 21 6113 3688 x76...

Page 3: ...3 Electrical Safety Warnings 3 Environmental Safety Cautions and Warnings 4 Safety Information 4 Environmental 4 Electrical 4 Safety Standards 4 Chapter 1 Introduction and Specifications 7 Introducti...

Page 4: ...D 20 Ethernet Port 1 Primary 20 Ethernet Port 2 with Built in Switch 20 Chapter 5 Operation and Maintenance 21 Location Diagnostics 21 Status LED 21 SixTRAK IPm RTU Controller Memory 21 Chapter 6 Red...

Page 5: ...s 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and foun...

Page 6: ...uct information can be obtained by contacting the local sales representative or Red Lion through the contact numbers and or e mail addresses listed on the inside of the front cover Warnings and Cautio...

Page 7: ...Do not work on equipment or cables during periods of lightning activity ALERTE Ne pas travailler sur le mat riel ou les c bles pendant les p riodes d activit de la foudre WARNING Properly ground the u...

Page 8: ...while circuit is live unless area is known to be non hazardous ALERTE Risque d explosion Ne pas brancher ou d brancher les connexions lorsque le circuit est sous tension sauf si la zone est connue pou...

Page 9: ...ee warning below For marine and maritime compliance do not install this product within 5 meters of a standard or a steering magnetic compass WEEE compliance These devices comply with the WEEE directiv...

Page 10: ...6 Preface Drawing No LP1106 Safety Information Revision B ST IPm 8460 SixTRAK IPm RTU Controller...

Page 11: ...ol Kit is a configuration calibration and maintenance tool for Red Lion hardware Use the I O Tool Kit to configure I O features perform channel by channel calibrations in meaningful engineering units...

Page 12: ...101 104 Latency typical 10 Mbps 16 s 100 Mbps 5 s Switching Method Store and Forward Maximum Throughput 90 Mbps Network 2 MDIX Auto Cable Sensing Auto Sensing Speed and Flow Control MTBF 820 000 hour...

Page 13: ...evaluated for ATEX IEC 60079 0 Edition 7 0 IEC 60079 7 Edition 5 1 The equipment shall be installed in an enclosure that provides a degree of protection not less than IP54 in accordance with EN IEC 60...

Page 14: ...10 Chapter 1 Introduction and Specifications Drawing No LP1106 Ordering Information Revision B ST IPm 8460 SixTRAK IPm RTU Controller...

Page 15: ...unication accessories Snap the pre wired RJ45 to DB9 adapter to the RJ45 patch cord not supplied Connect this cable between one of the serial RS232 ports RJ45 connector on your SixTRAK IPM RTU Control...

Page 16: ...mount the ST IPm 8460 unit Note Allow enough room to route Ethernet copper or fiber optic cables Figure 2 1 Mounting and Removal Instructions 1 Mounting 2 Recommended DIN rail mounting steps 1 Hook th...

Page 17: ...DIN rail spacing is 8 inches This spacing allows room for wire duct to be installed without obstructing field wiring installation The Red Lion components are typically installed against one another b...

Page 18: ...sions 0 25 0 64 cm 2 92 7 42 cm 0 17 0 43 clear for 8 screw DIN EN 50022 not included 4 47 11 35 cm 4 75 12 07 cm 3 00 7 63 cm 3 17 8 05 cm 2 55 6 48 cm Side View 4 27 10 83 cm 4 47 11 35 cm 2 92 7 42...

Page 19: ...een 10 to 30 volts Wire Gauge Capacity of terminal plug 12 to 28 AWG 3 31 TO 0 081 mm2 copper wire Torque 4 4 inch lbs 0 5 N m Strip insulation back on conductor 0 25 to 0 27 Redundant Power Inputs Th...

Page 20: ...rformance is seen when following the guidelines set out in that standard EtherTRAK 2 Guidelines The specifications below are application guidelines to get the best performance from the SixTRAK IPm RTU...

Page 21: ...network creates a reliable redundant ring capable of recovering very quickly Multiple Rings may be connected to the SixTRAK IPm RTU Controller through switches and can be connected to either Network...

Page 22: ...connect one device to each port The EtherTRAK 2 I O modules must be in 2 Network Star mode to use this network configuration Figure 3 2 Star Topology Recommended Switches The SixTRAK IPm RTU Controlle...

Page 23: ...its Make sure to use a good quality communication cable with three conductors twisted is preferred plus a shield To prevent ground loops the shield should be connected to chassis ground on only one en...

Page 24: ...s four switched ports standard shielded RJ45 connectors to connect to peripheral equipment such as Red Lion s EtherTRAK 2 I O modules All are 10 100BaseTx auto detecting and auto crossover Ethernet po...

Page 25: ...hdog has detected a problem Try clearing the memory and reloading the project from the I O Tool Kit Long ON Blink Using controller redundancy a long on blink 90 ON 10 OFF indicates that the controller...

Page 26: ...22 Chapter 5 Operation and Maintenance Drawing No LP1106 SixTRAK IPm RTU Controller Memory Revision B ST IPm 8460 SixTRAK IPm RTU Controller...

Page 27: ...ready to exchange I O data with your Windows applications via DDE OPC or direct DLL calls Refer to the How to Access Sixnet I O From a Windows Application topic in the Sixnet I O Tool Kit online help...

Page 28: ...24 Chapter 6 Red Lion Windows Software Drawing No LP1106 Red Lion Software Revision B ST IPm 8460 SixTRAK IPm RTU Controller...

Page 29: ...ll not be billed if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on the RO form and supplied to th...

Page 30: ...RADE OR OTHERWISE Customer shall be responsible for determining that a Product is suitable for Customer s use and that such use complies with any applicable local state or federal law b The Company sh...