Sixnet
®
Series RAM
®
9000
Hardware Guide
1-9
Product Overview
Revised 2016-02-12
Specifications
•
Derate to 0.7 A up to 50°C
•
Derate to 0.55 A up to 70°C
•
Derate to 0.4 A up to 80°C
•
Derate to 0.3 A p to 85°C
•
Min. output load per channel = 1 mA
•
Max. OFF state leakage current = <0.05 mA
•
Inrush current (100 mA surge) = 5A
•
Typical ON voltage drop (@1 A) = 0.13 VDC
•
Short circuit protection = self-reset fuses (trip above 1.5 Amp at 20C)
Relay Outputs Specs:
•
1 channel
•
Relay type = Form C (NO/NC)
•
Minimum output voltage = 0 VAC/VDC
•
Maximum output voltage = 110 VDC, 125 VAC
•
Minimum switching capacity = 10
μ
A, 10 mV DC
•
Maximum load current per output (30 VDC) = 2 Amps
•
Maximum load current per output (125 VAC) = 0.3 Amps
•
Minimum OFF resistance = 1000 Meg Ohms
•
Maximum relay turn ON time = 4 ms
•
Maximum relay turn OFF time = 4 ms
•
Load current versus contact voltage chart:
Analog Input Specs:
•
3 channels
•
Ranges = 4-20 mA or 0-10 VDC
•
Ranges are software selectable