background image

N-Tron

®

 Series NT24k

®

 Compact Hardware Manual

1-17

P

RODUCT

 O

VERVIEW

R

EVISED

 2017-09-11

NT24

K

-11FX3

D

RAWING

 N

O

. LP0987-D

 

1.7.3

 

Dimensions

All specifications are subject to change. Consult the company website for more information.

Summary of Contents for N-Tron NT24k-16M Series

Page 1: ...N Tron Series NT24k Compact Series Hardware Manual September 2017 Industrial Managed Gigabit Ethernet Switches ...

Page 2: ...017 Red Lion Controls Inc All rights reserved Red Lion the Red Lion logo N Tron and NT24k are registered trademarks of Red Lion Controls Inc All other company and product names are trademarks of their respective owners ...

Page 3: ...en Garde et Avertissements viii General Safety Cautions and Warnings Précautions et Avertissements de Sécurité Générale viii Electrical Safety Warnings Avertissements de Sécurité électrique ix Environmental Safety Cautions and Warnings Sécurité Environnementale Mises en Garde et Avertissements x Hazardous Location Warnings Les Avertissements d Emplacement Dangereux x Surrounding Air Temperature Te...

Page 4: ...ions 1 7 1 4 3 Dimensions 1 8 1 5 NT24k 10FX2 1 9 1 5 1 Features and Benefits 1 9 1 5 2 NT24k 10FX2 Specifications 1 10 1 5 3 Dimensions 1 11 1 6 NT24k 10GX2 1 12 1 6 1 Features and Benefits 1 12 1 6 2 NT24k 10GX2 Specifications 1 13 1 6 3 Dimensions 1 14 1 7 NT24k 11FX3 1 15 1 7 1 Features and Benefits 1 15 1 7 2 NT24k 11FX3 Specifications 1 16 1 7 3 Dimensions 1 17 1 8 NT24k 11GX3 1 18 1 8 1 Fea...

Page 5: ... 14 2 NT24k 8TX POE Specifications 1 37 1 14 3 Dimensions 1 38 1 15 NT24k 16TX POE 1 39 1 15 1 Features and Benefits 1 39 1 15 2 NT24k 16TX POE Specifications 1 40 1 15 3 Dimensions 1 41 1 16 NT24k 10FX2 POE 1 42 1 16 1 Features and Benefits 1 42 1 16 2 NT24k 10FX2 POE Specifications 1 43 1 16 3 Dimensions 1 44 1 17 NT24k 10GX2 POE 1 45 1 17 1 Features and Benefits 1 45 1 17 2 NT24k 10GX2 POE Spec...

Page 6: ... 24 1 Features and Benefits 1 66 1 24 2 NT24k 12SFP DM4 POE Specifications 1 67 1 24 3 Dimensions 1 68 1 25 NT24k 16M12 1 69 1 25 1 Features and Benefits 1 69 1 25 2 NT24k 16M12 Specifications 1 70 1 25 3 Dimensions 1 71 1 26 NT24k 16M12 POE 1 72 1 26 1 Features and Benefits 1 72 1 26 2 NT24k 16M12 POE Specifications 1 73 1 26 3 Dimensions 1 74 1 27 NT24k 16M12 R 1 75 1 27 1 Features and Benefits ...

Page 7: ... 7 NT24k 12SFP DM4 1 86 1 31 8 NT24k 10 11 12 14FX POE 1 86 1 31 9 NT24k 10 11 12 14GX POE 1 87 1 31 10 NT24k 12SFP DM4 POE 1 87 1 31 11 NT24k 16M12 1 88 1 31 12 NT24k 16M12 POE 1 88 1 31 13 NT24k 16M12 R 1 88 1 31 14 NT24k 16M12 POE R 1 88 Chapter 2 Hardware Installation 2 89 2 1 Unpacking 2 89 2 2 Mounting the NT24k Unit 2 89 2 3 Power Source 2 91 2 4 Grounding the Unit 2 96 2 5 Configurable Ala...

Page 8: ...rt 15 of the Federal Communications Commission FCC A Rules Interference Every effort has been made to ensure that this equipment is designed to comply with the limits for a Class A digital device as described in the FCC Rules This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful Interference 2 This device must acc...

Page 9: ...age numérique de la classe A répond à toutes les exigences de l interférence canadienne causant des règlements d équipement L opération est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interférence nocive et 2 ce dispositif doit accepter n importe quelle interférence reçue y compris l interférence qui peut causer l opération peu désirée Environmental Impact Statement ...

Page 10: ...ents de Sécurité Générale Issue Revision Release Date Content Description Initial release February 2015 Initial document release Revision A June 2015 New models added Revision B April 2016 Revised with updated ODVA requirements Added safety updates Revision C August 2016 New model added Revision D September 2017 New models added CAUTION If the equipment is used in the manner not specified by Red L...

Page 11: ...unless qualified to do so Do not substitute unauthorized parts or make unauthorized modifications to the unit ATTENTION Ne pas effectuer de services sur l appareil s il n est pas qualifié pour le faire Ne pas substituer pièces non autorisées ou de modifications non autorisées de l appareil WARNING Properly ground the unit before connecting anything else to the unit Units not properly grounded may ...

Page 12: ...on de matériel électrique dans un tel environnement constitue un danger certain WARNING Disconnect the power and allow to cool 5 minutes before touching AVERTISSEMENT Déconnectez le câble d alimentation et laisser refroidir 5 minutes avant de la toucher CAUTION This equipment is suitable for use in Class I Division 2 Groups A B C and D or non hazardous locations only Combinations of equipment in y...

Page 13: ...a is known to be non hazardous AVERTISSEMENT Risque d explosion Ne pas brancher ou débrancher les connexions lorsque le circuit est sous tension sauf si la zone est connue pour être non dangereux WARNING Exposure to some chemicals may degrade the sealing properties of materials used in the following devices Relay U1 and DIN Rail models AVERTISSEMENT L exposition à certains produits chimiques peut ...

Page 14: ...pliance IEEE 1613 Electric Utility Substations NEMA TS1 TS2 Traffic Control Other ABS Type Approval for Shipboard Applications EMC Directive 2014 30 EU LV Directive 2014 35 EU GOST R RoHS Compliant Regulatory Information M12 Models Product Safety ANSI ISA 12 12 01 2015 Nonincendive Electrical Equipment for Use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locati...

Page 15: ... 61373 and EN 45545 2 Designed In Compliance IEEE 1613 Electric Utility Substations NEMA TS1 TS2 Traffic Control Other EMC Directive 2014 30 EU LV Directive 2014 35 EU GOST R RoHS Compliant Note Product safety certifications for M12 PoE models pending Remarque Les certifications de sécurité pour M12 Modèles PoE en attente ...

Page 16: ...pper only ports or a mix of copper and fiber ports IEEE 802 3af at PoE models are also available 1 1 2 Performance NT24k managed switches provide uncompromising performance in harsh environments including network features like N Ring VLAN Quality of Service QoS port mirroring IGMP SNTP and SNMP Additionally the NT24k offers IEEE 802 1x with RADIUS remote server authentication to ensure port securi...

Page 17: ...C IP20 8 4 NT24k 14FX6 14 DIN Rail 40 to 85 C IP20 8 6 NT24k 14GX6 14 DIN Rail 40 to 85 C IP20 8 6 NT24k 12SFP DM4 12 DIN Rail 40 to 85 C IP20 8 Up to 4 NT24k 8TX POE 8 DIN Rail 40 to 80 C IP20 8 8 PoE NT24k 16TX POE 16 DIN Rail 40 to 80 C IP20 16 16 PoE NT24k 10FX2 POE 10 DIN Rail 40 to 80 C IP20 8 8 PoE 2 NT24k 10GX2 POE 10 DIN Rail 40 to 80 C IP20 8 8 PoE 2 NT24k 11FX3 POE 11 DIN Rail 40 to 80 ...

Page 18: ...its Eight 10 100 1000Base T X RJ45 Ports Easily transitions to Gigabit network requirements Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and set...

Page 19: ...ady Input Current Inrush Current BTU HR 10 49 VDC 490 mA 24 VDC 22 A 33 ms 24 VDC 40 14 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT X E...

Page 20: ...ries NT24k Compact Hardware Manual 1 5 PRODUCT OVERVIEW REVISED 2017 09 11 NT24k 8TX DRAWING NO LP0987 D 1 3 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 21: ...s 16 10 100 1000Base T X RJ45 Ports Easily transitions to Gigabit network requirements Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Si...

Page 22: ... Steady Input Current Inrush Current BTU HR 10 49 VDC 710 mA 24 VDC 22 A 33 ms 24 VDC 58 14 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT...

Page 23: ...17 09 11 PRODUCT OVERVIEW DRAWING NO LP0987 D NT24k 16TX 1 8 N Tron Series NT24k Compact Hardware Manual 1 4 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 24: ...enefits 10 Copper and Fiber Ports Eight 10 100 1000Base T X copper ports Two 100BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection ...

Page 25: ...Inrush Current BTU HR 10 49 VDC 750 mA 24 VDC 21 A 30 ms 24 VDC 61 44 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT Eight RJ45 copper por...

Page 26: ...es NT24k Compact Hardware Manual 1 11 PRODUCT OVERVIEW REVISED 2017 09 11 NT24k 10FX2 DRAWING NO LP0987 D 1 5 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 27: ...atures and Benefits 10 Copper and Fiber Ports Eight 10 100 1000Base T X copper ports Two 1000BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic po...

Page 28: ...t Inrush Current BTU HR 10 49 VDC 780 mA 24 VDC 22 6 A 30 ms 24 VDC 63 89 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT Eight RJ45 copper...

Page 29: ...7 09 11 PRODUCT OVERVIEW DRAWING NO LP0987 D NT24K 10GX2 1 14 N Tron Series NT24k Compact Hardware Manual 1 6 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 30: ...atures and Benefits 11 Copper and Fiber Ports Eight 10 100 1000Base T X copper ports Three 100BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic p...

Page 31: ...nt Inrush Current BTU HR 10 49 VDC 750 mA 24 VDC 21 A 30 ms 24 VDC 61 44 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT Eight RJ45 ports 1...

Page 32: ...es NT24k Compact Hardware Manual 1 17 PRODUCT OVERVIEW REVISED 2017 09 11 NT24K 11FX3 DRAWING NO LP0987 D 1 7 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 33: ...atures and Benefits 11 Copper and Fiber Ports Eight 10 100 1000Base T X copper ports Three 1000BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic ...

Page 34: ... Inrush Current BTU HR 10 49 VDC 780 mA 24 VDC 22 6 A 30 ms 24 VDC 63 89 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT Eight RJ45 copper ...

Page 35: ...7 09 11 PRODUCT OVERVIEW DRAWING NO LP0987 D NT24K 11GX3 1 20 N Tron Series NT24k Compact Hardware Manual 1 8 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 36: ...res and Benefits 12 Mixed Copper and Fiber Ports Eight 10 100 1000Base T X copper ports Four 100BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic...

Page 37: ...rush Current BTU HR 10 49 VDC 750 mA 24 VDC 21 A 30 ms 24 VDC 61 44 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT Eight RJ45 TX copper po...

Page 38: ...es NT24k Compact Hardware Manual 1 23 PRODUCT OVERVIEW REVISED 2017 09 11 NT24K 12FX4 DRAWING NO LP0987 D 1 9 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 39: ...atures and Benefits 12 Copper and Fiber Ports Eight 10 100 1000Base T X copper ports Four 1000BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic p...

Page 40: ...Inrush Current BTU HR 10 49 VDC 780 mA 24 VDC 22 6 A 30 ms 24 VDC 63 89 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT Eight RJ45 TX coppe...

Page 41: ...7 09 11 PRODUCT OVERVIEW DRAWING NO LP0987 D NT24K 12GX4 1 26 N Tron Series NT24k Compact Hardware Manual 1 10 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 42: ...eatures and Benefits 14 Copper and Fiber Ports Eight 10 100 1000Base T X copper ports Six 100BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic po...

Page 43: ... Inrush Current BTU HR 10 49 VDC 750 mA 24 VDC 21 A 30 ms 24 VDC 61 44 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT Eight RJ45 copper po...

Page 44: ...es NT24k Compact Hardware Manual 1 29 PRODUCT OVERVIEW REVISED 2017 09 11 NT24K 14FX6 DRAWING NO LP0987 D 1 11 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 45: ...eatures and Benefits 14 Copper and Fiber Ports Eight 10 100 1000Base T X copper ports Six 1000BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic p...

Page 46: ...t Inrush Current BTU HR 10 49 VDC 780 mA 24 VDC 22 6 A 30 ms 24 VDC 63 89 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT Eight RJ45 copper...

Page 47: ...7 09 11 PRODUCT OVERVIEW DRAWING NO LP0987 D NT24K 14GX6 1 32 N Tron Series NT24k Compact Hardware Manual 1 12 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 48: ...s Features and Benefits 12 Mixed Copper and SFP Ports Eight 10 100 1000Base T X copper ports Four SFP ports 100Base and 1000Base transceivers sold separately Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play ...

Page 49: ...0 49 VDC 760 mA 24 VDC 20 4 A 30 ms 24 VDC 62 26 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT Eight RJ45 copper ports 100 1000 Base SX L...

Page 50: ... NT24k Compact Hardware Manual 1 35 PRODUCT OVERVIEW REVISED 2017 09 11 NT24K 12SFP DM4 DRAWING NO LP0987 D 1 13 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 51: ...se T X RJ45 Ports Easily transitions to Gigabit network requirements Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all ports simultaneously Extended Environmental Specifications 40 to 80 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Gr...

Page 52: ...all PoE ports 68 A 09 ms 24 VDC 122 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Tria...

Page 53: ... 09 11 PRODUCT OVERVIEW DRAWING NO LP0987 D NT24K 8TX POE 1 38 N Tron Series NT24k Compact Hardware Manual 1 14 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 54: ...ures and Benefits Features and Benefits 16 10 100 1000Base T X RJ 45 Copper Ports Easily transitions to Gigabit network requirements Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output 240 Watt PoE budget configurable across all 16 ports up to 30 Watts per port Extended Environmenta...

Page 55: ...oad on all PoE ports 67 A 096 ms 24 VDC 122 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 20...

Page 56: ... NT24k Compact Hardware Manual 1 41 PRODUCT OVERVIEW REVISED 2017 09 11 NT24K 16TX POE DRAWING NO LP0987 D 1 15 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 57: ...ight 10 100 1000Base T X copper ports supporting PoE on each port Two 100BaseFX fiber ports with SC ST connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 to 80 C operating tempe...

Page 58: ... 2 ms 24 VDC 122 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be b...

Page 59: ...09 11 PRODUCT OVERVIEW DRAWING NO LP0987 D NT24K 10FX2 POE 1 44 N Tron Series NT24k Compact Hardware Manual 1 16 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 60: ... 100 1000Base T X copper ports supporting PoE on each port Two 1000BaseFX fiber ports with SC connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 to 80 C operating temperature ra...

Page 61: ...s 60 A 2 ms 24 VDC 122 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bul...

Page 62: ... NT24k Compact Hardware Manual 1 47 PRODUCT OVERVIEW REVISED 2017 09 11 NT24K 10GX2 POE DRAWING NO LP0987 D 1 17 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 63: ...00 1000Base T X copper ports supporting PoE on each port Three 100BaseFX fiber ports with SC ST connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE outputs on all RJ45 ports simultaneously Extended Environmental Specifications 40 to 80 C operating temperature...

Page 64: ...2 ms 24 VDC 122 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bu...

Page 65: ...09 11 PRODUCT OVERVIEW DRAWING NO LP0987 D NT24K 11FX3 POE 1 50 N Tron Series NT24k Compact Hardware Manual 1 18 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 66: ... 100 1000Base T X copper ports supporting PoE on each port Three 1000BaseFX fiber ports with SC connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 to 80 C operating temperature ...

Page 67: ...A 2 ms 24 VDC 122 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be ...

Page 68: ... NT24k Compact Hardware Manual 1 53 PRODUCT OVERVIEW REVISED 2017 09 11 NT24K 11GX3 POE DRAWING NO LP0987 D 1 19 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 69: ...100 1000Base T X copper ports supporting PoE on each port Four 100BaseFX fiber ports with SC ST connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 to 80 C operating temperature ...

Page 70: ... 2 ms 24 VDC 122 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be b...

Page 71: ...09 11 PRODUCT OVERVIEW DRAWING NO LP0987 D NT24K 12FX4 POE 1 56 N Tron Series NT24k Compact Hardware Manual 1 20 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 72: ... 100 1000Base T X copper ports supporting PoE on each port Four 1000BaseFX fiber ports with SC connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 to 80 C operating temperature r...

Page 73: ...A 2 ms 24 VDC 122 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be ...

Page 74: ... NT24k Compact Hardware Manual 1 59 PRODUCT OVERVIEW REVISED 2017 09 11 NT24K 12GX4 POE DRAWING NO LP0987 D 1 21 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 75: ...100 1000Base T X copper ports supporting PoE on each port Six 100BaseFX fiber ports with SC ST connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 to 80 C operating temperature r...

Page 76: ... 2 ms 24 VDC 122 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be b...

Page 77: ...09 11 PRODUCT OVERVIEW DRAWING NO LP0987 D NT24K 14FX6 POE 1 62 N Tron Series NT24k Compact Hardware Manual 1 22 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 78: ... 100 1000Base T X copper ports supporting PoE on each port Six 1000BaseFX fiber ports with SC connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 to 80 C operating temperature ra...

Page 79: ... 60 A 2 ms 24 VDC 122 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must...

Page 80: ... NT24k Compact Hardware Manual 1 65 PRODUCT OVERVIEW REVISED 2017 09 11 NT24K 14GX6 POE DRAWING NO LP0987 D 1 23 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 81: ... Eight 10 100 1000Base T X copper ports Four SFP ports 100Base and 1000Base transceivers sold separately Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 to 80 C operating temperature ra...

Page 82: ...utput Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1...

Page 83: ... 11 PRODUCT OVERVIEW DRAWING NO LP0987 D NT24K 12SFP DM4 POE 1 68 N Tron Series NT24k Compact Hardware Manual 1 24 3 Dimensions All specifications are subject to change Consult the company website for more information ...

Page 84: ... cable connections ensure continuity in applications where motion or vibration exist IP67 Enclosure Dustproof Protection against low high water jets Protection from immersion in water up to 1 meter Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications High tolerance to shock and vibration 40 to 85 C operating temperat...

Page 85: ...urrent BTU HR 10 49 VDC 700 mA 24 VDC 37 0 A 0 022 ms 24 VDC 58 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000Base T 16 M12 X Code Ports Pin As...

Page 86: ...ompact Hardware Manual 1 71 PRODUCT OVERVIEW REVISED 2017 09 11 NT24K 16M12 DRAWING NO LP0987 D 1 25 3 Dimensions All specifications are subject to change Consult the company website for more information FRONT BOTTOM RIGHT ...

Page 87: ... connections ensure continuity in applications where motion or vibration exist IP67 Enclosure Dustproof Protection against low high water jets Protection from immersion in water up to 1 meter Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure Extended Environmental Specifications High tolerance to shock and ...

Page 88: ... ms 24 VDC 123 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bul...

Page 89: ...UCT OVERVIEW DRAWING NO LP0987 D NT24K 16M12 POE 1 74 N Tron Series NT24k Compact Hardware Manual 1 26 3 Dimensions All specifications are subject to change Consult the company website for more information FRONT BOTTOM RIGHT ...

Page 90: ...00Base T M12 X Code Ports M12 cable connections ensure continuity in applications where motion or vibration exist Two pairs of Bypass Ports 7 8 and 9 10 IP67 Enclosure Dustproof Protection against low high water jets Protection from immersion in water up to 1 meter Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications...

Page 91: ... Current BTU HR 10 49 VDC 850 mA 24 VDC 37 0 A 0 022 ms 24 VDC 70 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 85 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000Base T 16 M12 X Code Ports Pin ...

Page 92: ...mpact Hardware Manual 1 77 PRODUCT OVERVIEW REVISED 2017 09 11 NT24K 16M12 R DRAWING NO LP0987 D 1 27 3 Dimensions All specifications are subject to change Consult the company website for more information FRONT BOTTOM RIGHT ...

Page 93: ...e 16 10 100 1000Base T M12 X Code Ports M12 cable connections ensure continuity in applications where motion or vibration exist Two pairs of Bypass Ports 7 8 and 9 10 IP67 Enclosure Dustproof Protection against low high water jets Protection from immersion in water up to 1 meter Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a...

Page 94: ...44 ms 24 VDC 131 Power over Ethernet PoE PoE Standard PoE Output Power PSE Type IEEE 802 3af at Gigabit Endspan PSE 57 VDC 30 Watts output 25 5 W at PD Type 2 Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 to 80 C 40 to 85 C 10 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be b...

Page 95: ...CT OVERVIEW DRAWING NO LP0987 D NT24K 16M12 POE R 1 80 N Tron Series NT24k Compact Hardware Manual 1 28 3 Dimensions All specifications are subject to change Consult the company website for more information FRONT BOTTOM RIGHT ...

Page 96: ... link between ports ACT Green Data is active between ports Activity light blink rate indicates activity not necessarily the volume of activity Off Data is inactive between ports LNK ACT Green 10 100 1000 Mb Link between ports Data is inactive between ports Yellow 10 100 1000 Mb Link between ports Data is active between ports The blink rate indicates activity not necessarily the volume of activity ...

Page 97: ...terface Compact Models Improper or Failed negotiation with the PD Overload or over current condition Short circuit condition Under voltage condition IP67 Models Module Status Indicator State Description Steady Off The switch is not powered up Steady Green The switch is operating normally Flashing Green The switch has not been configured Flashing Red A recoverable minor fault has occurred Steady Re...

Page 98: ... 19 dBm 15 dBm 5 dBm 5 dBm RX Sensitivity Max 31 dBm 31 dBm 34 dBm 34 dBm Wavelength 1310 nm 1310 nm 1310 nm 1550 nm Fiber Length 550 m 50 125 µm 300 m 62 5 125 µm 10 km 40 km 80 km TX Power Min 9 5 dBm 9 5 dBm 5 dBm 0 dBm RX Sensitivity Max 17 dBm 20 dBm 23 dBm 24 dBm Wavelength 850 nm 1310 nm 1310 nm 1550 nm Laser Type VCSEL FP DFB DFB Fiber Length 2 km 10 km 40 km 80 km TX Power Min 19 dBm 15 d...

Page 99: ...ndustrial Ethernet Switch NT24k NM PMK NT24k Non Modular Panel Mount Kit NTCD CFG NT24k Configuration Recovery Device NTPS 24 20 DIN Rail Power Supply 20 Amp 24 VDC NTPS 48 10 DIN Rail Power Supply 10 Amp 48 VDC Part Number Description NT24k 16TX 16 Port 10 100 1000Base T X Managed Industrial Ethernet Switch NT24k NM PMK NT24k Non Modular Panel Mount Kit NTCD CFG NT24k Configuration Recovery Devic...

Page 100: ...T 6 100BaseFX singlemode ports NTCD CFG NT24k Configuration Recovery Device NTPS 24 1 3 DIN Rail Power Supply 1 3 Amp 24 VDC NT24k NM PMK NT24k Non Modular Panel Mount Kit Part Number Description NT24k 10GX2 SC 10 Port Gigabit Managed Industrial Ethernet Switch 8 10 100 1000BaseT 2 1000BaseSX multimode 550m ports NT24k 10GXE2 SC ZZ 10 Port Gigabit Managed Industrial Ethernet Switch 8 10 100 1000Ba...

Page 101: ...X POE 10 Port Gigabit Managed PoE Industrial Ethernet Switch 8 10 100 1000BaseT 2 100BaseFX multimode 2km ports NT24k 10FXE2 XX YY POE 10 Port Gigabit Managed PoE Industrial Ethernet Switch 8 10 100 1000BaseT 2 100BaseFX singlemode ports NT24k 11FX3 XX POE 11 Port Gigabit Managed PoE Industrial Ethernet Switch 8 10 100 1000BaseT 3 100BaseFX multimode 2km ports NT24k 11FXE3 XX YY POE 11 Port Gigabi...

Page 102: ...eSX multimode 550m ports NT24k 14GXE6 SC ZZ POE 14 Port Gigabit Managed PoE Industrial Ethernet Switch 8 10 100 1000BaseT 6 1000BaseLX singlemode ports NTCD CFG NT24k Configuration Recovery Device NTPS 24 20 DIN Rail Power Supply 20 Amp 24 VDC NTPS 48 10 DIN Rail Power Supply 10 Amp 48 VDC NT24k NM PMK NT24k Non Modular Panel Mount Kit Where ZZ 10 40 or 80 Part Number Description NT24k 12SFP DM4 P...

Page 103: ...ded female connectors Max 240W PoE Load NTCD CFG M12 NT24k Configuration Recovery Device M12 NTPS 24 20 DIN Rail Power Supply 20 Amp 24 VDC NTPS 48 10 DIN Rail Power Supply 10 Amp 48 VDC Part Number Description NT24K 16M12 R IP67 rated 16 Port Gigabit Managed Industrial Ethernet Switch with M12 8 pin X coded female connectors with bypass relay NTCD CFG M12 NT24k Configuration Recovery Device M12 N...

Page 104: ...sed to securely mount the NT24k Compact Series products to a panel or other flat surface A clearance of one inch should be observed on the sides back top and bottom to allow proper ventilation Also a cable bend radius of two inches should be observed for the front and top side of the unit DIN Rail Mounting Instructions Install the switch to standard 35mm DIN Rail as shown in the diagram above 1 Fi...

Page 105: ...lot provided on the DIN Rail clip 5 Using the base of the switch as a pivot point apply upward force on the screwdriver to release the DIN Rail clip 6 With the DIN Rail clip latching mechanism released continue to rotate the switch upward and away from the panel 7 Once the switch has been rotated upward remove the screwdriver Carefully lift the switch upward and away from the DIN Rail and panel Bu...

Page 106: ...WARE INSTALLATION REVISED 2017 09 11 POWER SOURCE DRAWING NO LP0987 D NT24k 16M12 Dimensions and Drill Hole Locations 2 3 Power Source Non PoE Compact Models The NT24k non PoE Power over Ethernet Compact models come with a redundant 10 49 VDC power input ...

Page 107: ...ilar to Red Lion s P N NTPS 24 20 Note LEDs are described in detail in LEDs on page 81 Unscrew and remove the DC voltage input plug from the power input header Install the DC power cables into the plug observing polarity Plug the voltage input plug back into the power input header Tightening torque for the terminal block power plug is 0 5 Nm 0 368 lb ft Verify that the power LED is on Note When a ...

Page 108: ...eet the requirements for IEEE 802 3af and or IEEE 802 3at for it to negotiate properly Devices with invalid PD signatures or non PoE devices will not be powered ON PoE capable models will remove power from the Powered Device if any of the following conditions occur Minimum power requirements are not satisfied The PD must draw minimum required current set forth by 802 3af at specifications in order...

Page 109: ...al block 4 For redundant inputs repeat the above steps by inserting the positive negative wires into the V2 V2 circular openings on the power connector by firmly pushing them into the terminal block 5 Use 12 14 gauge solid or stranded wire to connect the Chassis Grounding point located near the power input terminal to a known good ground 6 Verify that no exposed conductors are touching each other ...

Page 110: ...t redundant inputs are utilized repeat the above steps by removing the positive negative wires from the V2 V2 circular openings on the power connector General Power Supply Notes for NT24k PoE models NT24k PoE models use 12 14 gauge solid or stranded wire with ferrules Voltage drop across the power wires between the source power supply and the NT24k unit should be considered during installation 0 5...

Page 111: ...t The grounding of any control system is an integral part of the design The optimum noise immunity and emissions are obtained when the NT24k chassis is connected to earth ground via a 12 14 gauge wire for the POE models and 14 18 gauge drain wire for all other units The NT24k units provide a ground lug or grounding point see illustrations that is used to provide a safe grounding path of the device...

Page 112: ...xternal warning device based on an event The current carrying capacity is 1A at 24VDC It is normally open and the relay closes when a fault condition occurs though this can be reversed via configuration These pins can be used to connect an external warning device such as a light in order to provide an external alarm The conditions for generating a fault condition closing the relay can be configure...

Page 113: ...rt on the FX FXE GX GXE models should be connected to the RX port of the far end station The RX port on the FX FXE GX GXE versions should be connected to the TX port of the far end station Warning Avertissement Creating a network loop without employing a network path protocol such as N Ring N Link or RSTP is an illegal operation that can create a network storm which will crash the network La créat...

Page 114: ...or Crimp Specifications 2 8 NTCD CFG Configuration Device Warning Avertissement Do not use connect or disconnect unless the area is known to be non hazardous Connection or disconnection in an explosive atmosphere could result in an explosion Ne pas utiliser de connecter ou déconnecter sauf si la zone est connue pour être non dangereuse Connexion ou la déconnexion dans une atmosphère explosive pour...

Page 115: ...ion is used to access the Command Line Interpreter CLI or PPP Point to Point Protocol USB Cable Connect the USB port of your PC and the Switch using a standard USB cable A cable with a Type A connector for the PC end and a Type B connector for the switch end must be used For NT24k 16M12 models a cable with a Type A connector for the PC end and an M12 Mini B USB connector for the switch end must be...

Page 116: ...e non hazardous Connection or disconnection in an explosive atmosphere could result in an explosion La connection USB est pour la connexion temporaire seulement Ne pas utiliser connecter ou déconnecter sauf si la zone est connue pour être non dangereuse Connexion ou la déconnexion dans une atmosphère explosive pourrait entraîner une explosion 2 10 Cleaning Clean only with a damp cloth Excess moist...

Page 117: ...REVISED 2017 09 11 HARDWARE INSTALLATION DRAWING NO LP0987 D CLEANING 2 102 N Tron Series NT24k Compact Hardware Manual This page intentionally left blank ...

Page 118: ...2 168 1 201 as the fallback address 2 The following login screen will appear 3 For the User Name enter admin all lowercase 4 For the password enter admin all lowercase Note For security purposes it is recommended that the password be changed according to your internal policies Login credentials can be changed on the User Management page 5 Upon successfully logging in depending on the unit used a s...

Page 119: ...THERWISE Customer shall be responsible for determining that a Product is suitable for Customer s use and that such use complies with any applicable local state or federal law b The Company shall not be liable for a breach of the warranty set forth in paragraph a if i the defect is a result of Customer s failure to store install commission or maintain the Product according to specifications ii Cust...

Reviews: