background image

MIL312 Hardware Manual_Rev_2-7-14.docx  

Page 4 of 16   

              Last Revised: 25-Feb-14

 

 

 

PO W E R   I N PU T  

 

Connector: MIL-STD-38999 Series III receptacle with shell size A, style 98, 3 pin 
contacts and A keying

 

 

Input voltage range: 18-36 VDC (continuos), 28 VDC Nominal

 

 

Input power: 35 W (typical under full load) 

 

 

Reverse polarity protection

 

 

Meets MIL-STD-704 A/E/F and MIL-STD-1275 A/B/D for power protection

 

 

Surge protection: 100 volts for 1 second 

 

 

Transient protection: 15,000 watts peak  

 

Spike protection: 5,000 watts (10x for 10 uS) 
or  250 volts (50x for 100 uS)

 

 
EN V I R O N ME N T A L  

 

Operating temperature: -40 to +75°C 

(cold startup at -40°C)

 

 

Storage temperature: -40 to +85 °C

 

 

Humidity (non-condensing) 5 to 95% RH

 

 

Vibration, shock and Immersion  per MIL-STD-810G

 

 

Water Jet Test per MIL-STD-108E

 

 

Vent plug for high altitude operation

 

 
PH Y S I C A L  

 

Dimensions (L x W x H) 13 x 6 x 3.75

” (330 x 152 x 95 mm) 

 

Weight (including caps) 9.8 lbs (4.45 Kg) 

 

IP67 dust, oil and water-tight package protection

 

 
ST A N D A R D S   C O MP L I A N C E  

 

MIL-STD-461F for EMI performance. CE101, CE102, RE102  

 

MIL-STD-461F for EMC performance. CS101, CS114, CS115, CS116, RS101, RS103 

 

MIL-STD-810G and MIL-STD-108E for environmental performance 

 

MIL-STD-704 A/E/F and MIL-STD-1275 A/B/D for power protection (Power Input) 

 

  SWITCHING FEATURES 

 

Flow control: IEEE 802.3x (Full Duplex) & Back-Pressure (Half Duplex) 

 

Spanning Tree Protocol (STP per IEEE 802.1D) plus 

o

 

 IEEE 802.1w Rapid Spanning Tree Protocol (RSTP) 

o

 

 IEEE 802.1s Multiple Spanning Tree Protocol (MSTP) 

o

 

 BPDU forwarding and filtering 

 

Virtual Local Area Networks (VLANs) 

o

 

 802.1Q tag-based with 256 VLANs and 4K VLAN ID 

o

 

 802.1v protocol and port-based VLAN 

o

 

 Voice and Private VLAN 

o

 

 QVRP and Q-in-Q (double tagging) 

 

Link Aggregation Control Protcol (LACP per IEEE 802.3ad) 

o

 

 Static trunk (8 trunks and up to 8 ports per trunk) 

o

 

 Traffic load balancing 

 

Internet Group Management Protocol

 

(IGMP)

 

o

 

 IGMP v1, v2 and v3 with up to 255 multicast groups 

o

 

 IGMP snooping and querying 

o

 

 Immediate leave and leave proxy 

o

 

 Throttling and filtering 

 

Multicast VLAN Registration (MVR) 

 

IEEE 802.1ab Link layer Discovery Protocol (LLDP) 

 

Quality of Service (QoS)

 

with 4 priority queues

 

o

 

 Scheduling schemes: WRR and Strict priority  

o

 

 CoS per IEEE 802.1p and IP DSCP-based 

o

 

 DiffServ (DS): ingress, egress and remarking 

 

Rate limiting (ingress and egress) 

o

 

 64Kbps to 100/1000Mbps 

o

 

 Per port CoS 

 

 

   

Summary of Contents for MIL312-1

Page 1: ...ntents at a Glance Section 1 General Information Page 3 Section 2 Mechanical and Installation Page 7 Section 3 Power and Communication Wiring Page 9 Section 4 LEDs Page 14 Section 5 Pressure Vent Page 15 Section 6 Service and Contact Information Page 16 This manual applies to the following products MIL312 1 IP67 managed Layer 3 Ethernet switch with 12 Gigabit ports ...

Page 2: ...rranties are hereby expressly disclaimed No oral or written information or advice given by Red Lion or Red Lion s representative shall create a warranty or in any way increase the scope of this warranty This limited warranty is in lieu of all other warranties whether oral or written expressed or implied Red Lion s liability shall not exceed the price of the individual units which are the basis of ...

Page 3: ... all ports these industrial Ethernet switches will intelligently route Ethernet messages only out the appropriate port The major benefits of this are increased bandwidth and speed reduction or elimination of message collisions and deterministic performance when tied with real time systems These switches support 10BaseT 10 Mbps 100BaseT 100 Mbps and 1000BaseT 1000 Mbps on 12 ports Each of these por...

Page 4: ...S114 CS115 CS116 RS101 RS103 MIL STD 810G and MIL STD 108E for environmental performance MIL STD 704 A E F and MIL STD 1275 A B D for power protection Power Input SWITCHING FEATURES Flow control IEEE 802 3x Full Duplex Back Pressure Half Duplex Spanning Tree Protocol STP per IEEE 802 1D plus o IEEE 802 1w Rapid Spanning Tree Protocol RSTP o IEEE 802 1s Multiple Spanning Tree Protocol MSTP o BPDU f...

Page 5: ...AND MONITORING RS232 console port via MIL STD 38999 series III connector w shell size A style 35 6 contacts A keying IP Address assignment Static DHCP and BOOTP CLI Command Line Interface via console or Telnet Web interface HTTP HTTPS SSL SNMP v1 v2 v3 Simple Network Management Protocol SNMP Traps for event notification RMON Remote Monitoring Groups 1 2 3 and 9 sFlow network wide traffic monitorin...

Page 6: ... the switch INSTALL THE SWITCH IN ACCORDANCE WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES LIGHTNING DANGER DO NOT WORK ON EQUIPMENT DURING PERIODS OF LIGHTNING ACTIVITY Consignes de Sécurité 1 Le strict respect de ces avertissements contribuera à assurer la sécurité de l installation le démarrage et le fonctionnement de l appareil 2 INSTALLEZ L APPAREIL CONFORMÉMENT AUX CODES ÉLECTRIQUES LOCAUX ET...

Page 7: ...to use thermal grease or a gap pad between the MIL312 unit and the surface it is mounted on The MIL312 case is designed to act as a heat sink and this will ensure cooler operation of the unit 0 375 9 52mm 0 275 6 98mm 0 375 9 52mm 0 575 14 61mm 0 212 5 40mm 0 250 6 35mm 0 250 6 35mm 0 250 6 35mm Console Power Vent Gig Ports 1 2 3 4 5 6 7 8 9 10 11 12 5 980 151 89mm 4 687 119 06mm 2 116 53 75mm 1 1...

Page 8: ...MIL312 Hardware Manual_Rev_2 7 14 docx Page 8 of 16 Last Revised 25 Feb 14 12 980 329 69mm 3 754 95 35mm 3 254 82 65mm 2 744 69 70mm 2 004 50 90mm 0 350 8 89mm 3 600 91 44mm ...

Page 9: ...rosion resistance All mating connectors will self lock with one 360 degree turn of the coupling nut Typical MIL STD 38999 Connectors shown with tethered plugs Typical MIL STD 38999 Plug not typically supplied with switch Grounding Use the provided 8 32 ground stud to connect the switch to a suitable safety chassis or earth ground Use of heavy gauge at least 16 AWG grounding wire is recommended Mak...

Page 10: ...in the diagram below Power Receptacle Power Receptacle Pinout Recommended Plug Model D38999 26WA98SA w socket contacts and A keying Note The W in the part above indicates cadmium plating However you may use any plating option that you desire The mating receptacles on the switch have a RoHS compliant nickel plating DC Supply C B A No Connection Receptacle Shell A Insert 98 Contacts P Keying A ...

Page 11: ...this console port Console Receptacle Console Receptacle Pinout LED Control Shorting out pins 5 and 6 on the RS232 connector will turn off all LEDs while continuing regular switch operation Leave pins 5 and 6 open for normal LED function Recommended Plug Model D38999 26WA35PA w pin contacts and A keying Note The W in the part above indicates cadmium plating However you may use any plating option th...

Page 12: ...agement interfaces See the software user manual for details Ethernet Receptacle Ethernet Receptacle Pinout Typical Pinout Connections Pin 1 TX For 10 100 Pin 2 TX For 10 100 Pin 3 RX For 10 100 Pin 4 TX For Gig Pin 5 TX For Gig Pin 6 RX For 10 100 Pin 7 RX For Gig Pin 8 RX For Gig Recommended Plug Aero AE90 365 BN9 9PN Note This plug has a black nickel plating Contact Aero for other plating option...

Page 13: ...ange TX TX TX D1 BI DA BI DA white green white orange 3 white white RX RX RX D2 BI DB BI DB orange green 4 blue blue N A N A BI D3 N A BI DC white blue white blue 5 white white N A N A BI D3 N A BI DC blue blue 6 orange green RX RX RX D2 BI DB BI DB white orange white green 7 white white N A N A BI D4 N A BI DD brown brown 8 brown brown N A N A BI D4 N A BI DD white brown white brown BI BI directi...

Page 14: ...be on solid green when power is applied to the switch In the event of a power fault the LED will turn to solid amber The LED will also be solid amber during a portion of the boot up sequence Ethernet LEDs The switch has a set of LEDs to indicate the status of the Ethernet ports Each LED is labeled with the number of the port it represents They function as follows Solid Green 1000 Mbps linked detec...

Page 15: ...sult in condensation To prevent this the switch incorporates a pressure vent that adjusts the internal air pressure to match the surrounding external pressure At the same time the vent is IP67 rated and will not let moisture into the switch Assembled Pressure Vent Characteristics Air flow rate 0 4 l min at 0 bar ΔP to 5 0 l min at 1 bar ΔP Point of water entry 1 5 bar Temperature resistance 40 C t...

Page 16: ...umber in case the repair is not covered under our warranty You will not be billed if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on the RO form and supplied to the repair department before your unit arrives This helps us to provide you with the best service in the fastest manner Repairs are compl...