DESCRIPTION (Cont’d)

The program disable DIP switch, the code value, and an external user input 

selected for Program Disable can be utilized to provide multi-level protection 
against unwanted changes to data values and unit configuration.

The Legend Plus features enhanced serial communications. The serial port 

can be configured for connection to RS485 or RS232 devices. It can be used for 
data retrieval and for programming various data values.

Optional Legend Plus Programming Software for IBM

 compatible PCs is 

available to program all the Legend configuration parameters, such as messages, 
count modes, etc. The software allows unit configurations to be created, 
uploaded, downloaded and saved to a file for rapid programming of the Legend 
unit.

The six programmable User Inputs can be configured to provide a variety of 

functions. Four user inputs are located on the upper rear terminal block and the 
other two inputs are front panel function keys. The User Inputs can be 
configured to provide functions such as:

 Count 

Inhibit 

Reset

 

Message Request 

Message Cancellation

 Output 

Activation Output 

Deactivation

 

Program Disable 

View/Freeze Display

 

Print Request 

Skip Presets(outputs)

The units offer a choice of seven programmable counting modes for use in 

applications requiring Bi-directional, Anti-coincidence, and Quadrature 
counting. The count inhibit function can be utilized with all of these input 
response modes by programming User Input 4 for the Inhibit Count function. 
The input circuitry is switch selectable to accept signals from a variety of 
sources. In the Anti-coincidence mode both inputs are monitored simultaneously, 
so that no counts are missed, and the final count can be chosen as the sum or 
difference of the two inputs.

Rate, Process and Total displays have separate scaling and decimal point 

placement, for readouts in different units. The Counter Load feature enables the 
operator to modify the count value. This is useful when flawed material has 
been counted and it is necessary to adjust the count value accordingly.

The rate operates in the time interval method (1/tau) to calculate the rate 

value. This method insures high resolution at all input rates. Averaging can be 
accomplished by programming the Minimum and Maximum Update Time for 
the desired response. Extensive scaling capabilities allow practically any 
reading at very slow input rates.

The construction of the Legend Plus unit is a lightweight, high impact plastic 

case with a clear viewing window. The sealed front panel with silicone rubber 
keypad meets NEMA 4X/IP65 specifications for wash-down and/or dusty 
environments, when properly installed. Plug-in style terminal blocks simplify 
installation and wiring change-outs.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the 

manual or on equipment must be observed to ensure personal safety and to 
prevent damage to either the instrument or equipment connected to it. If 
equipment is used in a manner not specified by the manufacturer, the protection 
provided by the equipment may be impaired.

Do not use this unit to directly command motors, valves, or other actuators 

not equipped with safeguards. To do so, can be potentially harmful to persons 
or equipment in the event of a fault to the unit.

MODEL - LGPB

The process counter is used to monitor the count within the batch.  Presets 1 

through 4 can be assigned to the process counter or the rate indicator. Presets 3 
and 4 can also be assigned to either the batch counter or totalizer.

Presets 1 and 2 can activate relay outputs 1 and 2 respectively. Presets 3 and 

4 can activate the NPN open collector outputs O3-SNK and O4-SNK 
respectively.

MODEL - LGPM

The Multi Preset unit has 6 presets which can control NPN open collector 

outputs 01-SNK to 06-SNK respectively. Presets 1 through 6 can be assigned to 
either the rate or count display.

SPECIFICATIONS

1. 

DISPLAY:

 2x8, 0.3" (7 mm) high characters, negative image transmissive 

LCD, with Single (green or red) or Dual Color (green and red) LED 
backlighting.

2. 

POWER:

AC Operation

: 115/230 VAC ±10%, 50/60 Hz, 10 VA, switch selectable.

DC Operation

: +12 VDC ±20% @ 250 mA max.

3. 

MEMORY:

 Non-volatile memory retains all programming information. 

Count and Preset values are written to non-volatile memory when power is 
interrupted. All other programming parameters are written to memory when 
programming mode is exited. If power is removed while in the programming 
menu’s the parameters are stored to previously saved settings.

Data Retention

: 10 yr. min.

Message/Mnemonics Memory

:

792 (LGPB) / 804 (LGPM) bytes available (with factory settings loaded).

4. 

SENSOR POWER:

 +12 VDC ±25% @ 100 mA.

5. 

INPUTS A and B:

 DIP Switch selectable to accept count pulses from a 

variety of sources including switch contacts, outputs from CMOS or TTL 
circuits, magnetic pickups and all standard RLC sensors.

LOGIC

: Input trigger levels V

IL

 = 1.5 V

MAX

; V

IH

 = 3.75 V

MIN

.

Current sinking

: Internal 7.8 K

 pull up to +12 VDC, I

MAX

 = 1.9 mA.

Current sourcing

: Internal 3.9 K

 pull-down, 7.3 mA

MAX

 @ 28 VDC.

Debounce

: Damping capacitor provided for switch contact bounce. 

 

Limits count speed to 50 Hz and input pulse widths to 10 msec min.

MAGNETIC PICKUP

:

Sensitivity

: 200 mV peak.

Hysteresis

: 100 mV.

Input impedance

: 3.9 K

 @ 60 Hz.

Maximum input voltage

: ±50 Vp

Note: For magnetic pickup input, the sink/source DIP switch must be in the 

SRC position.

6. 

RATE ACCURACY:

 ±0.01%

7. 

RATE MINIMUM INPUT FREQUENCY:

 0.01Hz.

8. 

MAXIMUM COUNT RATE IN KHz:

MODEL

CNT + DIR

QUAD

ADD/ADD

ADD/SUB

X1

X2

X1

X2

X4

X1*

X1*

LGPB (Batch)

15

7

7

5.5

3

14

7

LGPM (Six Preset)

13

6

6

5

2.5

12

6

LGPBF (Foot-Inch)

15

7

7

5.5

3

15

7

Notes:

1. Maximum count rates given are for Process counter set for Auto reset with 

the auto cycle preset set to an equivalent of 100 count pulses or greater. 
With auto cycle presets less than 100 counts the maximum count rates may 
be lower. The actual Preset value for 100 count pulses, with Count 
SF=0.5000 and Count Scale Multiplier=X1, would be 50.

2. Maximum count rate given for X2 & X4 count modes are given for 50% 

duty cycle signals and Quad signals with 90° phase shift.

*

Inputs A & B count rates summed.

9. 

MAXIMUM COUNT CAPACITY:

Process or Count

: 9 digits internal (non-scaled), 6 digits displayable (scaled)

Batch Count

: 6 digits

Total Count

: 11 digits internal (non-scaled), 8 digits displayable (scaled)

10.

 CONTROL INPUTS:

Programmable user inputs (4)

:

USR INP 1 to 3

: Internal 10 K

 pull-up to +5 VDC, V

IL

 = 1.5 V

MAX

; V

IH

 

= 3.5 V

MIN

, response time = 30 msec typical, 100 msec max. 

(count rate 

dependent)

.

USR INP 4/INH

: Internal 10 K

 pull-up to +5 VDC, V

IL

 = 1.5 V

MAX

, V

IH

 

= 3.0 V

MIN

, response time = 30 msec typical, 100 msec max.

 (count rate 

dependent)

.

INHIBIT Response time = 50 

μ

sec max.

User Inputs Programmed for Binary Message Request

: Debounce = 

100 msec. 

(Binary message request inputs must be stable for 100 msec 

before a message is requested)

.

11.

 SERIAL COMMUNICATIONS:

Type

: Jumper selectable RS485 or RS232.

Can connect up to 32 units when using RS485 interface.

Baud Rate

: Programmable from 1200 to 9600.

Maximum Addresses

: Programmable from 00 to 99. (Actual number on a 

line is limited by hardware specifications)

Transmit Delay

: Programmable for 0.002 or 0.100 second.

Data Format

: 10 Bit Frame; 1 start bit, 7 or 8 data bits, 1 or no parity bit, 

and 1 stop bit. Parity is programmable for ODD (7 data bits), EVEN (7 
data bits), or NO Parity (8 data bits).

12. 

OUTPUT(S):

Solid-State

: Current sinking NPN open collector transistor.

V

CE

 = 1.1 V

SAT

 @ 100 mA max. V

OH

 = 30 VDC max.

(Internal Zener Diode Protection).

LGPM

RATE
PEAK

VALLEY

PROCESS

BATCH

TOTAL

(4 Presets)

RATE
PEAK

VALLEY

COUNT

(6 Presets)

LGPB & LGPBF

STANDARD INDICATION DISPLAYS 

& PRESETS FOR EACH MODEL

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Summary of Contents for Legend Plus Series

Page 1: ...or suffix This capability allows displays such as 1000 RPM 99999 Ft PRC 9999 etc The Legend Plus also features messaging capabilities that can inform the user of output actions or other events that o...

Page 2: ...ch can control NPN open collector outputs 01 SNK to 06 SNK respectively Presets 1 through 6 can be assigned to either the rate or count display SPECIFICATIONS 1 DISPLAY 2x8 0 3 7 mm high characters ne...

Page 3: ...us unit Also shown above right are four different views of the indication displays PROGRAMMABLE FUNCTIONS PRESET S Ranges from 99999 to 999999 Counter Load ranges from 99999 to 999999 SCALE FACTORS RA...

Page 4: ...disable DIP switch to provide a variety of program security modes External User Input only Inhibit Count Prevents pulses from being counted on Inputs A and B User Input 4 only The rate input is not af...

Page 5: ...c For total only the first character is transmitted A transmit and reset count capability allows the selected count values to automatically reset after the value is printed transmitted OPERATOR ACCESS...

Page 6: ...CK LABEL GLUE PRIORITY 6 TYPE 1L SCROL BLINKING MULTIPLEX CANCEL TIMED TIME SEC 1 COLOR GREEN MSG 6 6 TEXT CHECK TOP SUPPLY PRIORITY 6 TYPE 1L SCROL BLINKING MULTIPLEX CANCEL TIMED TIME SEC 1 COLOR GR...

Page 7: ...expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters wh...

Reviews: