background image

Setpoint 

 

Action

Setpoint

 

Select

Setpoint

 

Value

Output Reset

 

Action

Hysteresis 

Value

Off Time

 

Delay

On Time

 

Delay

Output Reset

 

With Display

 

Reset

Change Display 

Color with  Output Stat

e

Backlight  Unit Only

SPSE

L

4-SPt

Act-n

SPt-n

HYS-n

tON-n

tOF-n

rSt-n

rEn-n

ChC-

n

Standby

 

Operatio

n

Stb-

n

brn-

n

Probe  Burn-out Actio

n

Front Panel  Reset Enable

Front Panel 

Display 

Select Enable

Display 

Update Time

dSP-t

SEL

rSt

3-dSP

Display  Intensity  Level

COLOr

Display  Scroll  Enable

ScroL

Display  Color

d-LEV

Backlight Unit Only

Programming  Security Code

CodE

Display 

Decimal Point

Thermocouple 

Type

tYPE

Cold Junction Compensation

CJC

1-INP

Temperature 

Scale

SCALE

dECPt

USrIN

User Input  Function

Filter Setting

Display Offset 

Value

OFSEt

FILtr

Filter Band

bANd

U-ASN

User Input  Assignment

LO-En

Min Display 

Enable

Max Capture  Delay Time

Max Display 

Enable

HI-En

HI-t

2-SEC

Min Capture  Delay TIme

LO-t

Factory  Service  Operations

FCS

Access Code

 

For Service

 

Operation

s

CodE

PAr

Parity Bi

t

Baud Rat

e

bAUd

Data Bi

t

dAtA

5-SEr

Meter  Address

Addr

Abbreviated 

Printing

Abbr

Print  Option

s

OPt

SEL

RS

T

  

  

NO 

 

  

  

Pro

Exit 

Programming

  

End

SEL

RS

T

RS

T

RS

T

RS

T

RS

T

SEL

SEL

SEL

SEL

cuB5tc proGraMMinG QuicK overvieW

Press and hold 

SEL

 button 

to enter Programming

 Mode.

Summary of Contents for CUB 5TC-K

Page 1: ...ure personal safety and to prevent damage to either the device or equipment connected to it Do not use these products to replace proper safety interlocking No software based device or any other solid...

Page 2: ...nstallation Guidelines for additional information 8 MEMORY Nonvolatile E2PROM memory retains all programming parameters and max min values when power is removed 9 CONNECTIONS Wire clamping screw termi...

Page 3: ...nstalling the Meter INSTALLATION The meter meets NEMA 4X IP65 requirements when properly installed The unit is intended to be mounted into an enclosed panel Prepare the panel cutout to the dimensions...

Page 4: ...tive The following EMI suppression devices or equivalent are recommended Fair Rite part number 0443167251 RLC part number FCOR0000 Line Filters for input power cables Schaffner FN2010 1 07 Red Lion Co...

Page 5: ...order to preserve the safety of the meter application the power input common and the sensor input common must be suitably isolated from hazardous live earth referenced voltages or input common must b...

Page 6: ...ges to memory and return the meter to the Display Mode If power loss occurs before returning to the Display Mode verify recent parameter changes PROGRAMMING TIPS It is recommended to start with Module...

Page 7: ...SELECTION VOLt tc n N K tc b tc S tc K B S J tc j E tc E T tc t 0 OFSEt DISPLAY OFFSET VALUE The temperature display can be corrected with an offset value This can be used to compensate for probe erro...

Page 8: ...it will display CAL NO 3 Press the RST button to select INP 4 Press the SEL button Display reads 0 0u 5 With the voltage source set to zero press SEL Display reads CALC for about eight seconds 6 When...

Page 9: ...rogramming Immediate Access Entering Code 222 allows access regardless of security code 5 3 MODULE 3 Display and Front Panel Button Parameters 3 dSP SEL Pro Front Panel Display Select Enable Display U...

Page 10: ...anced Hys LO bL OUTPUT STATE OFF ON Hys SP SP Hys OFF TRIGGER POINTS High Acting Unbalanced Hys HI Ub 2 HYS n HYSTERESIS VALUE 1 to 59999 Enter desired hysteresis value See Setpoint Output Figures for...

Page 11: ...the output operates normally per the Setpoint Action and OutputReset Action NO Stb n STANDBY OPERATION YES NO When the user input or RST button is activated momentary action the corresponding on outpu...

Page 12: ...gramming Security Code CodE Display Decimal Point Thermocouple Type tYPE Cold Junction Compensation CJC 1 INP Temperature Scale SCALE dECPt USrIN User Input Function Filter Setting Display Offset Valu...

Reviews: