red lighting PIXEL MINI BAR 12 User Manual Download Page 5

 

 

DMX 512

 

The  unit  operates  using  a  digital  DMX  512  (1990)  signal.  Connection  between  the  controller  and 
the  projector  must  be  carried  out  using  appropriate  cables  with  low  capacitance  and  120  Ω  as 
impedance. 
Pin 1 connected to the ground, Pin 2 connected to the DATA-, Pin 3 connected to the DATA+. 
Do not connect the cable ground to the plug chassis. The plug housing must be isolated. 
Connect the controller signal to the DMX IN projector plug and connect it to the next projector by 
connecting the DMX OUT plug on first projector to the DMX IN plug of second one. 
By this way, all projectors are cascade connect. 
 

 

 
For installations where the DMX cable has to run a long distance or is in an electrically noisy 
environment, it is recommended to use a DMX terminator. This helps in preventing corruption of 
the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 
120 Ω resistor connected between pins 2 and 3, which is then plugged into the output XLR socket 
of the last fixture in the chain. 
Please see illustrations below. 
 

4

5

 

 

 

OPERATION INSTRUCTIONS 

1) AUTO RUN 
2) SOUND 
3) SLAVE 
4) DMX MODE 
 

 

Auto Run mode 

Press MODE button to show: 

AUTO RUN “FUNCTION” 
FQN:01-99 

FQN01-99 to adjust the Frequency 
 

 

Summary of Contents for PIXEL MINI BAR 12

Page 1: ......

Page 2: ...Silent Mounting Any position Adjustable mounting bracket Physical size Attached drawings Weight 6 2 Kg Packing dimension 95x17x20 cm Gross weight 6 7 kg Control protocol and programming USITT Dmx 512...

Page 3: ...perating the device Most damages are the result of unprofessional operation FIRE PREVENTION Never locate the fixture on any flammable surface Minimum distance from flammable material is 1 m Minimum di...

Page 4: ...anges due to environmental changes do not switch it on immediately The arising condensation could damage the device Leave the device switched off until it has reached operating temperature The applica...

Page 5: ...first projector to the DMX IN plug of second one By this way all projectors are cascade connect For installations where the DMX cable has to run a long distance or is in an electrically noisy environm...

Page 6: ...Dimm00 99 SP01 99 F00 99 042 059 Dimm00 99 SP01 99 F00 99 060 077 05 CHANG Dimm00 99 SP01 99 F00 99 078 095 06 FLOW1 Dimm00 99 SP01 99 F00 99 096 113 07 FLOW2 Dimm00 99 SP01 99 F00 99 114 131 08 FLOW3...

Page 7: ...Adjust the sensitivity via UP DOWN from 00 31 Adjust the frequency from 01 99 Invert Function Press MODE button the display will show FLOW INVERT ON OFF Via ON OFF you can adjust the flow running effe...

Page 8: ...ode CH1 DIMMER Master dimmer 000 255 0 100 CH2 Strobe 000 005 off 006 010 Blackout 011 033 Pulse Random from slow to fast 034 056 Ram up Random from slow to fast 057 079 Ram down random from slow to f...

Page 9: ...grams can be selected from 2 15 50 channel mode CH1 DIMMER Master dimmer 000 255 0 100 CH2 Strobe 000 005 off 006 010 Blackout 011 033 Pulse Random from slow to fast 034 056 Ram up Random from slow to...

Page 10: ...or jump from slow to fast 193 255 1 12 color fade from slow to fast CH52 CT 000 005 No function 006 255 CT from cool white to warm white CH53 Built in programs 000 005 No function 006 255 Built in pro...

Page 11: ...be adhered by a skilled installer and any safety problems have to be removed In order to make the projector in good condition and extend the life time we suggest a regular inspection Should you need...

Reviews: