4
Replacing The Quad Seal
Removing the Pump
DANGER! Always disconnect, lock out, and tag the power before starting to service the pump.
When servicing unit use non-sparking tools and use caution when removing or installing equipment to
avoid generating a spark.
1.
If a ball valve is installed down line from the pump, close it.
2.
If an electronic line leak detection transducer is installed, it must be removed from the leak detector port
following instructions in the appropriate Line Leak installation manual (see Figure 1). A mechanical line leak
detector does not need to be removed.
Figure 1. Electronic Line Leak Detector
3.
Back out the electrical yoke disconnect bolt (see Figure 2).
Figure 2. Packer
OFF
Line Leak Detector
Electric
a
l
Connector
Electric
a
l Connector
(Yoke) Di
s
connect Bolt
Lock Down Bolt