20-CLEANING
Technical Dept. - All rights reserved - Reproduction prohibited
CLEANING THE SMOKE DUCT AND FITTING
When the product has been extracted, it is possible to operate on the left side to clean and maintain the smoke fan (1). The smoke
extraction fan must obviously be removed for such maintenance to be performed.
A gasket (3) is applied on the fan outlet, which guarantees the tightness with the smoke fitting (2). Always ensure this gasket is intact and
replace it if required. The gasket can also be adjusted via a screw. The pressure on the fitting can be increased or decreased by loosening
the screw.
The flue connection is housed, with its ash collection compartment (4), on the rear/side of the product, where the fan outlet is located.
Also clean this compartment with a vacuum cleaner by inserting the nozzle on the fan inlet hole.
Then clean the smoke outlet system, especially around the fittings, curves and any horizontal sections. For information on cleaning the
flue, contact a chimney sweeper.
ATTENTION! The frequency with which the smoke outlet system is cleaned depends on the use of the product and the
type of installation.
We recommend relying on an authorised support centre for end-of-season cleaning and maintenance, as they will
carry out all of the previously mentioned operations and also inspect the stove components.
OTHER CHECKS
All gaskets fitted on components subject to maintenance (smoke extraction fan, inspection panels, etc...) must be replaced when these
parts are removed for maintenance. Check the tightness of the gaskets on the firebox door and, if required, contact an authorized support
centre for them to be replaced.