• This device is intended for outdoor use only.

• This Torch Kit is designed for use with a 

Vapor-Withdrawal LP-Gas Cylinder.

FOR YOUR SAFETY!

If You Smell Gas:

1. Shut off gas to the device.

2.  Extinguish any open flame.

3.  Check the device for leaks using soapy water.

4.  DO NOT attempt to relight the device until  

  leaks are repaired and there is no gas smell

DO NOT use this device in areas where 

gasoline or other liquids having flammable 

vapor are stored or used.

Note: Unpack and inspect for damage. 

1. 

Using thread compound, connect male end of   

hose to OUT fitting of regulator. Tighten 

Securely with a wrench. 

2. Using thread compound, connect male end of 

P.O.L. fitting (brass left hand fitting that screws 

into the propane cylinder) to IN fitting of 

regulator. Tighten Securely with a wrench.

3. Using thread compound, attach other male end 

of hose to the torch. Tighten Securely with a 

wrench.

4. See “Connecting To The Supply Cylinder.”

Assembly Instructions

Connecting To The 

Supply Cylinder

The propane supply cylinder used with this torch 

should be no less than 100 lb. capacity and must be 

designed, fabricated, tested and marked in 

accordance with regulations of the U.S. Department 

of Transportation, the Canadian Transport 

Commission or the Interstate Commerce 

Commission. 

Supply cylinders must be arranged 

to provide for vapor withdrawal from the 

operating cylinder.
1.  

Inspect the nut/nipple of the P.O.L. connection on 

the LP-Gas hose. Check for dents or physical 

damage. The O-ring should be present on nipple 

fitting. If damage is evident, call for replacement 

parts.

2.

  Be certain the supply cylinder valve is fully 

turned off. Remove the protective plastic plug 

from the cylinder valve outlet connection.

Continued

Never attempt to store the torch while it is hot. 

When the torch is stored indoors, the 

connection between the LP-Gas supply cylinder 

and the torch must be disconnected and the 

cylinder removed form the torch and stored in 

accordance with Chapter 5 of ANSI/NFPA 58, 

the standard for storage and handling of 

liquefied petroleum gases. Do not store the 

torch in locations where it may be damaged.

WARNING

The gas supply hose shall be protected from 

traffic, building materials and contact with hot 

surfaces during use and while in storage.

• Sur

faces of the torch may be cleaned with soap 

or detergent and water solutions. Do not use 

petroleum-based cleaners to clean any 

components of the torch or the torch body.

• Rem

ove any  debris and combustible material 

from the torch. The torch must be kept clear and 

free from combustible materials, gasoline and 

other flammable vapors and liquids.

 The supply hose assembly shall be visually 

inspected prior to each torch use. If there is 

excessive abrasion or wear , or the hose is cut, it 

must be replaced prior to the torch being put into 

operation. The replacement hose assembly shall 

be specified by Flame Engineering, Inc. Contact 

Flame Engineering for further information.

Storage

Maintenance

JET C-INST-ENG-9-2010

WARNING:

DO NOT OPERATE THIS EQUIPMENT IF:

•  

You are subject to seizures, loss of consciousness,  

or fainting.

•  

You have been drinking alcohol, using illicit 

drugs, or prescription drugs that might effect your  

judgment or balance.

•  

You have not read or do not understand the 

operator’s manual.

•  

You are not capable of safely operating this type  

of equipment.

DO NOT ALLOW CHILDREN TO OPERATE 

THIS EQUIPMENT.

FLAME ENGINEERING, INC.

PO Bo

x 577 •

 W. HWY 4

LaCrosse, Kansas 67548

785-222-2873 • 

FAX 785-222-3619

Toll Free 800-255-2469 

www.FlameEngineering.com

1.

 Slowly open the LP-Gas cylinder valve. Check 

all gas connections to the torch for leaks with a 

leak detection solution, such as soapy water. 

Leaks will be indicated by forming bubbles 

around the source. Please allow one minute for 

bubbles to appear. Repair all leaks and test for 

leaks prior to lighting torch.

2.

 Familiarize yourself with the functions of the 

squeeze valve operations. The pilot valve knob 

is used for lighting the torch and adjusting the 

pilot flame. Once the desired pilot flame is 

achieved, the squeeze handle is depress to give 

the required working flame pattern.   

continued

Lighting Instructions

IMPORTANT NOTE

•  If no leaks are found, proceed with lighting

 the  

  torch.

•  A

lways use a flint lighter to ignite the torch. 

  DO NOT USE MATCHES OR CIGARETTE   

  LIGHTER TO IGNITE THE TORCH.

•  Be certain the flame adjusting 

valve is closed   

  before opening the LP-Gas cylinder valve.

Connecting To The Supply Cylinder Cont.

3. 

Connect the P.O.L. nut/nipple fitting on the 

hose to the propane supply cylinder by turning 

the left hand threaded P.O.L. nut counter 

clockwise into the cylinder valve outlet. Snug 

the connection tight with a wrench. DO NOT 

OVER TIGHTEN.

4.

 Be certain the flame adjusting valve is closed 

before opening the LP-Gas cylinder valve.

5. 

Slowly open the cylinder valve. Check all 

LP-gas connections for leaks using soapy water 

or suitable leak detection solution. DO NOT 

USE MATCHES OR OPEN FLAME TO 

CHECK FOR LEAKS. Do not attempt to 

operate the torch if there is evidence of a leak 

or at any time the odor of gas is detected.