background image

PO Box 577 • West Hwy 4
LaCrosse, KS 67548-0577
1-800-255-2469  •  785-222-2873  •  Fax 785-222-3619
www.FlameEngineering.com

OPERATING INSTRUCTIONS FOR THE “Hot Box”
RED DRAGON CH 220, CH 225 AND CH 250 CONSTRUCTION HEATERS

Questions?

 If you have any questions about the operations of the CH 220, CH 225 or CH 250 call your local

distributor or Flame Engineering, Inc. at 1-800-255-2469 or fax 785-222-3619.

Parts List

1.

P-3200 W (CH 220)

Excess Flow P.O.L.

P-W 795 (CH 225 & CH 250) Hand Tighten Excess Flow P.O.L.

2.

R-700 C

18 P.S.I. Preset Regulator

3.

HP 10 TS (CH 220)

U.L. Listed 10’ LP Gas Hose

HP 25 TS (CH 225)

U.L. Listed 25’ LP Gas Hose

HP 50 TS (CH 250)

U.L. Listed 50’ LP Gas Hose

4.

1/4” Female x 3/8” Male Flare Elbow

5.

H-19 H

Safety Valve

6.

M-3012

12” Thermocouple

7.

Model 21

Ignitor with Lead Wire (3309)

8.

332

Spark Plug

9.

100-CH 221

Heater Burner

10.

V-326

Flame Control Valve

11.

1/4” Elbow

12.

CH 221

Complete Burner/Control Assembly

(Includes everything except hose, regulator & P.O.L.)

1

2

3

4

5

6

7

8

9

10

11

Safety & Operating Information

Burner Securing Bolt

Heat Shield

Heater Cabinet

CH220INST12/10/03

12

Summary of Contents for CH 220

Page 1: ... 50 hose Special Features The Red Dragon HOT BOX made of sturdy rectangular construction offers the following important features not found on other construction heaters Heater Dimensions 16 1 2 H x 21 1 2 W x 26 D STRONG STACKABLE WON T TIP Low profile prevents accidental tipping Stackable for convenient storage High heat output close to the surface means a warmer working area More radiating surfa...

Page 2: ...nd comply with minimum clearances as stated on operating instructions Keep fuel containers at least 10 feet from heater Cylinders with 100 pound capacities are recommended for peak performance Do not move handle or service heater while it is in operation or still hot from use Using soapy water check all connections for gas leaks and test function of all moving parts Perform these checks and tests ...

Page 3: ...se Heat Pattern Heated Air Deflected Downward Cool Air Drawn In Lighting Instructions 1 Remove unit from box Be sure to remove all packaging 2 Visually inspect all hose for cuts nicks or abrasions 3 Place unit on noncombustible surface and keep the unit away from all combustibles 4 Connect unit to a 100 lb LP cylinder configured for vapor withdrawal 5 Be sure control valve on unit is closed 6 Slow...

Page 4: ... P W 795 CH 225 CH 250 Hand Tighten Excess Flow P O L 2 R 700 C 18 P S I Preset Regulator 3 HP 10 TS CH 220 U L Listed 10 LP Gas Hose HP 25 TS CH 225 U L Listed 25 LP Gas Hose HP 50 TS CH 250 U L Listed 50 LP Gas Hose 4 1 4 Female x 3 8 Male Flare Elbow 5 H 19 H Safety Valve 6 M 3012 12 Thermocouple 7 Model 21 Ignitor with Lead Wire 3309 8 332 Spark Plug 9 100 CH 221 Heater Burner 10 V 326 Flame C...

Reviews: