background image

14W LED Emergency 
Slimline POLO Bulkhead 
with Microwave Sensor 

Installation Instructions p.1

This installation must be carried out by an electrician. 
Please read these instructions carefully before installation. 
Leave a copy for the user/maintenance engineer for future reference.

For models: POL14LEDEMS

Specification

• 

220-240V

• 

13.5W

• 

64pcs of 2835 SMD LED

• 

4000K Colour temperature

• 

1150 Lumen output

• 

120° Beam angle

• 

>82 Ra

• 

Three years guarantee

 Prepare the mains supply cable & fixing points on the chosen 

   mounting surface ensuring it is able to retain the weight of 
   the luminaire. 

 Pass the mains supply cable through the hole & grommet 

   provided in the base, position the base to the mounting 
   surface & secure using the screws provided. 

 It is the installer’s responsibility to ensure the fixing points 

   & cable entry point are appropriately sealed to maintain 
   the IP54 rating. Silicone bathroom sealant or equivalent is 
   recommended.  

 Route the mains supply cable to the terminal block on the 

   gear tray & terminate ensuring correct polarity is observed. 
   

WARNING: THIS LUMINAIRE MUST BE EARTHED.

 

   It is important that supply cables fitted to luminaires with an 
   electronic ballast do not run adjacent to leads connected to 
   the ballast output terminals so as not to affect radio 
   frequency interference suppression. 

 Secure the supply cable using the clamp provided in the base. 

 Refit the the gear tray & secure by retightening the screws. 

 Refit the diffuser & trim by placing over the base & rotating 

   clockwise until it locks into position. 

 Reconnect power supply & check for correct operation. 

   Luminaires fitted with electronic ballasts are exempt from 
   insulation resistance tests as this may cause damage to the 
   ballast. 

Red Arrow Trading

Elsworth House, Herries Road South, Sheffield, S6 1QS

T:

 0800 195 0006     

F:

  0870  043  3946      

E:

 [email protected]      

www.redarrowtrading.com

Description of Microwave Sensor

 The microwave sensor option offers presence 

   detection to provide automatic control of lighting 
   loads. It is installed inside the luminaire so does 
   not affect external aesthetics or the IP Rating. 
   Manual adjustments on the sensor allow it to be 
   individually tailored to suit your application.  

Safety

 This is a mains powered product. It is designed to be 

   installed by a qualified electrician and in accordance 
   with the applicable building and electrical 
   regulations. Before installation or maintenance the 
   electrical supply to the product must be isolated. 

Installation Instructions 

 Remove the diffuser & trim from the base by rotating anti-

   clockwise to unlatch, then pull away. 

 Loosen the three gear tray retaining screws, rotate the gear 

   tray anti-clockwise to align the screw heads with the large 
   aperture of the keyhole slots & remove the gear tray 
   away from the base. There is a retaining strap to assist with 
   installation. 

Further Instructions for Emergency 

version

 In addition to the above instructions, a secondary “un-

   switched” live supply should be fed to the luminaire, in line 
   with the “switched” mains supply. This “un-switched” supply 
   MUST be taken from the same phase as the “switched” 
   supply & MUST be wired at the switchboard so that upon 
   test, it is isolated at the same time as the “switched” supply.

Summary of Contents for Slimline POLO POL14LEDEMS

Page 1: ...il it locks into position Reconnect power supply check for correct operation Luminaires fitted with electronic ballasts are exempt from insulation resistance tests as this may cause damage to the ballast Red Arrow Trading Elsworth House Herries Road South Sheffield S6 1QS T 0800 195 0006 F 0870 043 3946 E sales redarrowtrading com www redarrowtrading com Description of Microwave Sensor The microwa...

Page 2: ... any high voltage or insulation resistance testing otherwise irreparable damage will occur to luminaire components When the lamp operates from the battery supply it will be at a reduced light level so ensure cleanliness of luminaires is maintained so as not to affect performance To maintain full operational status spare lamps should be held for immediate changing in case of failure TESTING FOR EME...

Page 3: ...s for the annual test at all stages of equipment life TESTING LOG BOOK Luminaire Type Luminaire Location No 14W LED Emergency Slimline POLO Bulkhead with Microwave Sensor Installation Instructions p 3 For models POL14LEDEMS Month Test Year 1 Year 2 Year 3 Year 4 Year 5 signed date signed date signed date signed date signed date 1 FUNCTIONAL 2 FUNCTIONAL 3 FUNCTIONAL 4 FUNCTIONAL 5 FUNCTIONAL 6 FUN...

Page 4: ...n front of the sensor head These sensor kits are capable of switching controlling more than one luminaire in a master slave set up This is done by linking non sensored fittings slaves to the one with the sensor fitted master using the live output from the sensor NOTE DO NOT link other fittings containing MW sensors together in this way as it can cause false triggering of the sensors 14W LED Emerge...

Page 5: ...es Setting Length 1 10 seconds 2 1 minute 3 2 minutes 4 5 minutes 5 8 minutes 6 10 minutes 7 15 minutes 8 20 minutes 9 25 minutes 10 30 minutes Ratings Power supply 220 240V AC 5 60Hz Transmission Power 10mW Rated Load 1200W Power Consumption 0 9W approx Fault Finding If you are experiencing a problem please check through the following before making contact with our Customer Services Department Fa...

Page 6: ...king environment or installation not according to the current edition of the I E E Wiring Regulations BS7671 The guarantee is also invalidated if the luminaire has been Mega tested Should this product fail during the guarantee period it will be replaced free of charge subject to correct installation and return of the faulty unit We do not accept responsibility for any installation costs associated...