background image

INS

TALLA

TION INS

TRUCTIONS

Red Arrow Trading

Elsworth House, Herries Road South

Sheffield, S6 1QS

T: 0800 195 0006   F: 0870 195 0006 

E: [email protected] 

www.redarrowtrading.com

LED AC DRIVERLESS FLOODLIGHTS 

WITH PIR

FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR 

TESTING THE PIR

• Turn the SENS dial clockwise to the maximum point, turn  

   the TIME dial anti-clockwise to the minimum point, turn the 

   LUX dial clockwise to the maximum point.
• When you switch on the power, the fitting will not illuminate. 

   After a 30 second pre-heat, when the sensor gets the 

   induction signal, the load will turn on. Once the load switches 

   off, it will then turn on again after 5-15 seconds of the sensor 

   receiving an induction signal.
• After the sensor goes off, trigger the detection field after 

   5-10 seconds. The load should work. When there is no 

   induction signals in the sensor, the load should stop working.
• Turn the LUX dial anti-clockwise to the minimum point. If it  

   is adjusted to less than 3 LUX (dark), the load and sensor 

   should not work when testing in daylight. If you cover the 

   detection window with an opaque object, the load should 

   work. Under no induction signal condition, the load should 

   stop working within 5-15 seconds.
NOTE: WHEN TESTING IN DAYLIGHT, PLEASE TURN THE LUX 

DIAL TO THE     (SUN) POSITION, OTHERWISE THE SENSOR 
WILL NOT WORK!

TROUBLESHOOTING

THE SENSITIVITY IS POOR:
• Please check if there are any objects in the detection field. 
• Please check if the ambient temperature is too high. 
• Please check if the installation height corresponds to the 

  height shown in the instructions. 
• Please check if your direction of travel doesn’t create poor 

  sensitivity of the Sensor. (i.e. if you are walking towards the 

  fitting this creates poor sensitivity).
THE SENSOR CAN NOT SHUT OFF THE LOAD 

AUTOMATICALLY:
• Please check if there is continual signal in the detection field. 
• Please check if the time delay is at it’s maximum.
• Please check if the power corresponds to the instructions.

Reviews: