1. Using the O-ring Removal Pick, remove O-ring.

2. Clean sand, salt, other contaminants and old grease from O-ring.

3. Clean O-ring Groove and O-ring Contact Surface using a clean cotton swab.

4. Visually   and   physically   check   O-ring   by   passing   through   finger   tips,   feeling   for   cuts, 

cracks or any other defects. Such defects will cause water leakage, so be sure to replace 

the O-ring. Be careful not to stretch or pull the O-rings too much.

5. Squeeze a rice grain sized bead of silicone grease on your thumb and forefinger. Taking 

care not to pull or stretch the O-ring too much, uniformly spread grease on O-ring. Too 

little grease may cause the O-ring to twist in the groove, possibly causing water leakage.

6. Place O-ring in the O-ring Groove, making sure that it is uniform, not twisted or bulging 

out,  possibly  causing  water  leakage.   When  closing  back   cover,  visually check  O-ring 

surface, tracing a finger over it to making sure no hair, lint or other contaminants are 

attached.

IMPORTANT NOTES:

 

When housing is not used for long periods, remove O-ring and place in a plastic bags to 

keep it free of dust and other contaminants and store in a place out of direct sunlight. 

Please also be careful of prolonged exposure to direct sunlight during use. The O-ring 

may become deformed, causing water leakage.

After extended periods of non-use, soak empty housing in lukewarm water for half a day. 

Manipulate all buttons and dials several times. Using a soft, dry cloth wipe away water.

CAUTION!

 

O-ring are an essential part of waterproofing for this housing. Not properly greasing the O-

rings as directed may cause the O-ring to twist in the O-ring groove, possibly causing 

water leakage.

 

Always perform the above O-ring, O-ring groove and O-ring Contact Surface maintenance 

and greasing every time you open/close the housing.

 

Please pay close attention and make sure the O-ring are is twisted or bulging, free of any 

contaminants (dirt, hair, etc.), and that foreign objects do not obstruct proper closing of the 

housing Back Cover or attachment of the Lens Port.

 

DO NOT clean the housing with volatile organic solvents or chemical cleaning agents such 

as thinner, gasoline, and benzine, etc.

SPECIFICATIONS

Compatible Camera

CANON PowerShot G1 X Mark III

Maximum Depth

100 meters (328 feet)

Material

Main Body, Back Cover, Port: Corrosion-resistant Aluminum       

                                                Alloy, Anodized

Lever, Buttons, Dials:              POM, PC

Lens, Flash & LCD Window:   Hard Coat Acrylic

Screws, Springs, Shafts:         Stainless Steel, Galvanized

Dimensions 

Weight 

W153.3mm x D126.1mm x H108.5mm

Approx. 1.040Kg (Land w/Airlock Vacuum Valve)

Approx. 370g (Freshwater w/Camera)

Accessories

M67 Adpater Diffuser, Strobe Mask-External Strobe Connection 

Mount (Fiber-Optic/Sea&Sea), Wrist Strap, Reserve O-ring, O-

ring Removal Pick, O-ring Grease

8.

Summary of Contents for WHC-G1XMkIII

Page 1: ...CANON POWERSHOT G1 X Mark III Underwater Housing Recsea WHC G1XMkIII MANUAL Please read this manual before use NTF CORPORATION UH Division http www seatool net ...

Page 2: ...sunlight CAUTION To prevent water leakage and damage DO NOT disassemble or modify this housing Do not store the housing in areas of high humidity high or low temperatures or areas of extreme temperature fluctuation Doing so may cause deterioration of parts When diving use a method of water entry that protects the housing from shock which can cause water leakage If at all possible have housing hand...

Page 3: ...de Back Cover contact surface Complete camera function control Wide variety of supported RECSEA original options PACKAGE CONTENTS Be sure all items listed here are included WHC G1XMkIII Housing M67 Mount Adapter POM Diffuser Strobe Mask External Strobe Connection Wrist Strap Mount Fiber Optic Plug Reserve O ring O ring Grease w O ring Removal Pick GETTING TO KNOW YOUR WHC G1XMkIII HOUSING 2 ...

Page 4: ...t G1 X Mark III Underwater Housing Product Number WHC G1XMkIII Dealer Name Serial Number Dealer Stamp your company name and contact information purchase date model and serial number Recsea Seatool Manufacturing Sales NTF CORPORATION UH Division 390 1 Mii Midori Ku Sagamihara Shi Kanagawa 252 0151 Japan T 81 0 50 7541 0294 F 81 0 42 780 5720 http www seatool net E mail info seatool net ...

Page 5: ...ATTENTION Please refer to camera manual for explanation of all camera functions Open camera flash prior to installing camera 3 ...

Page 6: ...m proper housing and port O RING MAINTENANCE prior to installation Please conduct the following operations in a clean area with low humidity and dust 1 Remove camera lens cap strap and any other option s that might cause an obstruction 2 Check camera settings battery is charged and media storage capacity is sufficient 3 Make sure camera flash is open 4 Slowly and carefully install camera making su...

Page 7: ...e to manually close the strobe once removed from housing Use the Strobe Mask External Strobe Connection Mount to connect external strobe fiber optic cable When not in use store Strobe Mask External Strobe Connection Mount in a secure place so as not to lose it 1 Slide the Strobe Mask External Strobe Connection Mount down and over the Flash Window as required for attaching external flash cables 2 I...

Page 8: ... normal rates MAINTENANCE CAUTION Allowing saltwater and contaminants to dry on housing can damage functions and O rings possibly causing water leakage Clean with fresh water only using a soft dry cloth to wipe away water A complete housing overhaul is recommend once every year 1 After use in salt water wash off salt and other contaminants by soaking empty housing thoroughly in a bucket of fresh w...

Page 9: ...using water leakage After extended periods of non use soak empty housing in lukewarm water for half a day Manipulate all buttons and dials several times Using a soft dry cloth wipe away water CAUTION O ring are an essential part of waterproofing for this housing Not properly greasing the O rings as directed may cause the O ring to twist in the O ring groove possibly causing water leakage Always pe...

Page 10: ... up Lens SAL 02 ST ST Type Close up Lens SAL 03 ST ST Type Left Grip Tray STG 05L2 AL Dual Grip Tray STG 05W2 AL Left Grip Tray STG 05JL2 AL Dual Grip Extension STG 05JWEP AL Dual Grip Tray STG 05JL2 JWEP AL Lens Caddy Arm RHA 150 Bayonet Lens Caddy STG ADH 067 M67 Lens Caddy STG ADH M67 ST Lens Caddy ST H 01 AFTER SALE SERVICE Warranty period is two 2 years from purchase for general users six 6 m...

Page 11: ...y or if Warranty Information is altered Warranty does not cover any losses resulting from any malfunction of this product including those related to lost profits or any related expenses Seatool Recsea will stock parts necessary for repair for five 5 years from stop of production This product uses some degradable parts such as buttons and O rings Seatol Recsea recommends overhauling the housing onc...

Page 12: ...MEMO ...

Reviews: