Operation mode >
SERVICE STG
Maintenance >
Functions >
Configure System
Learning System >
Parameter >
PARAMETER
Driving Cycle >
Time delay open >
Drive >
Entrance System >
Control unit >
Locking >
Seal
DRIVING CYCLE
Seal >
Closing speed 20
Opening speed 36
Open >
Close >
Ramp
>
DRIVING CYCLE
2
0= no seal
1= appr. 4” seal
40= appr. 12” seal
Measured @ belt.
Obstruction
significantly reduced
during Seal - keep to
minmum.
Operation mode >
SERVICE STG
Maintenance >
Functions >
Configure System
Learning System >
Parameter >
PARAMETER
Driving Cycle >
Time delay open >
Drive >
Entrance System 0 >
Control unit >
Locking >
TIME DELAY OPEN
Time delay open 2
Time delay Rem. Sw 20
TIME DELAY OPEN
2
0 thru 20 are in
1 sec. intervals;
21 thru 40 are in
2 sec. intervals
providing 60 sec.
maximum delay.
Operation mode >
SERVICE STG
Maintenance >
Functions >
Configure System
Learning System >
Parameter >
PARAMETER
Driving Cycle >
Time delay open >
Drive >
Entrance System >
Control unit >
Locking >
TIME DELAY REM. SW
20
TIME DELAY OPEN
Time delay open 2
Time delay Rem. Sw 20
0 thru 20 are in
1 sec. intervals;
21 thru 40 are in
2 sec. intervals
providing 60 sec.
maximum delay.
SSK Delay 0
Reset with button 0
SSK Delay 0
Reset with button 0
Operation mode >
SERVICE STG
Maintenance >
Functions >
Configure System
Learning System >
Parameter >
PARAMETER
Driving Cycle >
Time delay open >
Drive >
Entrance System >
Control unit >
Locking >
SSK Delay
0
TIME DELAY OPEN
Time delay open 2
Time delay Rem. Sw 20
SSK Delay 0
Reset with button 0
Delay before door starts
opening from above
inputs terminals 11 & 12..
0= no delay
40= 8 second delay
SSK signal is only
delayed if door is closed.
Operation mode >
SERVICE STG
Maintenance >
Functions >
Configure System
Learning System >
Parameter >
PARAMETER
Driving Cycle >
Time delay open >
Drive >
Entrance System >
Control unit >
Locking >
Reset with button
0 Enabled
TIME DELAY OPEN
Time delay open 2
Time delay Rem. Sw 20
SSK Delay 0
Reset with button 0
Enables early closing by
sending same signal
again during hold open.
Disabled= no interruption
Enabled= Hold time can
be interrupted with a
signal from AKI, AKA, &
SSK.
1 Disabled
For compliance
with ANSI A156.10,
do not set less
than 2.
SSK, Special Activation,
& Time Delay Rem. Sw.
all refer to control input
terminals 11 & 12.