background image

Original  Instruction  Manual

AC400

 Air Cleaner

Important

For your safety read instructions carefully before 
assembling or using this product.
Save this manual for future reference.

Always wear safety glasses when 
using woodworking equipment.

Always read the instructions 
provided before using 
woodworking equipment.

i

Kg

Version 3.0

November 2012

To register this product please visit

www.recordpower.info

It is important to register your product as soon as possible in order to receive efficient after sales 

support and be entitled to the full 

5 year guarantee

. Your statutory rights are not affected. 

Please see back cover for contact details.

Summary of Contents for AC400

Page 1: ...odworking equipment Always read the instructions provided before using woodworking equipment i Kg Version 3 0 November 2012 To register this product please visit www recordpower info It is important to register your product as soon as possible in order to receive efficient after sales support and be entitled to the full 5 year guarantee Your statutory rights are not affected Please see back cover ...

Page 2: ...on of Symbols 2 General Health Safety Guidance 3 Additional Health Safety Guidance for the AC400 Air Cleaner 4 Record Power Guarantee 5 Specifications 6 Unpacking Checking Contents 7 Assembly 8 Operation 9 Electrical Connection Wiring Diagram 10 Parts Lists Diagrams EU Certificate of Conformity ...

Page 3: ...o use the machine Indicates an instruction that requires particular attention Wear protective eyewear Use respiratory protective equipment Use suitable protective footwear Use hearing protection Use protective work gloves Indicates a risk of severe personal injury or damage to the machine Indicates a risk of severe personal injury from electrical shock Risk of personal injury from lifting of heavy...

Page 4: ... covering to contain long hair 3 Safety warnings Find and read any warning labels on the machine It is important that any labels bearing health and safety warnings are not removed defaced or covered Replacement labels can be obtained by contacting our Customer Service Department 4 Familiarise yourself with the machine If you are not thoroughly familiar with the operation of this machine obtain adv...

Page 5: ...ely light the work area Lighting should be bright enough to eliminate shadow and prevent eye strain Do not use the machine in explosive environments eg in the presence of flammable liquids gases or dust The presence of high levels of dust created by machining wood can present a risk of fire or explosion Always use dust extraction equipment to minimise the risk 12 Keep other persons away and pets T...

Page 6: ... for a work piece that is longer or wider than the basic table or to help feed support or pull the work piece Do not attempt to machine more than one work piece at a time When feeding the work piece towards the blade or cutting tool never position your hands in direct line of the cutting path Avoid awkward operations and hand positions where a sudden slip could cause your hand or fingers to move i...

Page 7: ... determine that it will operate properly and perform its intended function Check for alignment of moving parts binding of moving parts breakage of parts and any other conditions that may affect the operation of the machine A guard or other part that is damaged should be properly repaired or replaced by a qualified person unless otherwise indicated in this instruction manual Do not use the machine ...

Page 8: ...nerally sell through a network of Authorised Dealers Details of Authorised Distributors for specific countries can be found in the Product manual or at www recordpower info Authorised Dealer is a retailer or business authorised to sell Record Power Products to end users 1 Guarantee 1 1 Record Power guarantees that for a period of 5 years from the date of purchase the components of qualifying Produ...

Page 9: ...w recordpower info for details The claim itself should be made in a letter setting out the date and place of purchase and giving a brief explanation of the problem which has led to the claim This letter should then be sent with proof of the purchase date preferably a receipt to Record Power or its Authorised Distributor If you include a phone number or email address this will help to speed up your...

Page 10: ...5 Microns Inner Filter 1 Micron Overall Dimensions L514 x W431 x H258 mm Sound Rating 1 m High Speed 69 dB Medium Speed 67 dB Low Speed 62 dB Air Flow High Speed 409 CFM Medium Speed 362 CFM Low Speed 260 CFM Motor 230V 50Hz 1 8 hp 100 W Full load current 0 43 A Timer Settings 1 2 and 4 hours Weight 14 kg ...

Page 11: ... 6 Unpacking Checking Contents Contents of Package 1 Air Filtration Unit 2 Remote Control 3 AA Batteries x 2 4 Rubber Coated Hook Bolts Nuts x 4 5 Mounting Hook Screws x 4 6 Chain sections x 4 1 4 2 3 5 6 ...

Page 12: ...er filters 2 The air filtration unit can be hung from the ceiling Remove four screws from cabinet top Fig 2 A 3 Hang the unit using four hook bolts Fig 2 B and four hex nuts Fig 2 C provided 4 The lock nut needs to be threaded almost all the way up the eyebolt Screw the eye bolt into the hole and tighten lock nut against the cabinet top You will need to hold the eyebolt so it does not spin while t...

Page 13: ...n Fig 3 Turns unit on and controls the three different fan settings Hi Mid and Low There is also an On Speed button Fig 4 on the switch panel to the rear of the machine which controls the speed and turns the unit ON in Low speed Off button Fig 3 turns the unit off There is also a manual off button Fig 4 on the switch panel to the rear of the machine The fuse is located beneath the rear control pan...

Page 14: ... dry before reinstalling into the machine The filters should be replaced and or cleaned depending on the amount of usage and the environment of your workshop Clogged filters will reduce the amount of air circulation There is an arrow indicating the air flow direction on the outer filter Fig 7 Make sure the filter is inserted facing the proper direction Replacement Filters SAC400 26 Inner Pocket Fi...

Page 15: ...3 plug for use in the UK always ensure that it is fitted with a fuse conforming to BS1362 appropriate to the rating of the machine If replacing the original fuse always fit a fuse of equivalent rating to the original Never fit a fuse of a higher rating than the original Never modify the fuse or fuse holder to accept fuses of a different type or size Where the current rating of the machine exceeds ...

Page 16: ...16 Original Instruction Manual AC400 Air Cleaner Version 3 0 November 2012 10 Parts Lists Diagrams ...

Page 17: ...rt Lock Nut M5 4 17 Handle Bracket 1 58 Motor 1 18 Pan Head Screw M5x16 2 59 Capacitor Cover 1 19 Flat Washer M5 3 60 Capacitor 1 20 Lock Washer M5 3 61 Fan Housing Cover 1 21 Hex Nut M5 6 62 Hook Screw 4 22 Pan Head Screw M5x12 1 63 Eye Bolt 4 23 External Tooth Lock Washer M5 2 64 Flange Nut M6 4 24 Wire 1 65 Hook Chain 4 25 Remote Control PCB 2 66 I D Label 1 26 Inner Pocket Filter 1 69 Switch B...

Page 18: ...Model No AC400 3 Serial No Conforms with the following directives Machinery Directive 2006 42 EC EN61029 1 2009 A11 2010 Low Voltage Directive 2006 95 EC EN55014 1 2006 A1 2009 EN55014 2 1997 A1 2001 A2 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Electromagnetic Compatibility 2004 108 E Signed Dated 01 11 2012 Andrew Greensted Managing Director EU Declaration of Conformity ...

Page 19: ...19 ...

Page 20: ...k Eire Record Power Ltd Unit B Adelphi Way Ireland Industrial Estate Staveley Chesterfield Derbyshire S43 3LS Tel 01246 561 520 www recordpower co uk Australia Tools 4 Industry Po Box 3844 Parramatta 2124 Tel 1300 124 422 Fax 1800 262 725 www recordpower com au New Zealand Tools 4 Industry Po Box 276079 Manukau City 2241 Tel 0800 142 326 Fax 09 2717 237 www recordpower co nz Made in China ...

Reviews: